The DOI matches its Crossref record.
Wide tourniquet cuffs more effective at lower inflation pressures
Open accessAbstract
Longitudinal and radial tissue-fluid pressure distributions were determined beneath and adjacent to wide (12 and 18 cm) pneumatic tourniquet cuffs placed on intact human cadaveric arms and legs, respectively. Tissue fluid pressures exhibited relatively broad maxima at midcuff, and in most cases showed no differences at the various depths studied. Limb circumference was not a determining factor in the transmission of pressure to deeper tissue. We also investigated the effect of four cuff sizes (4.5, 8, 12, and 18 cm) on eliminating blood flow to the lower legs of normal subjects. The cuff pressure required to eliminate blood flow decreased as cuff width increased; thigh circumference was a determining factor in the pressure required to eliminate blood flow while using the smaller cuffs, but not while using the 18-cm cuff. Thus, wide cuffs transmit a greater percentage of the applied tourniquet pressure to deeper tissues than conventional cuffs; accordingly, lower cuff pressures are required, which may minimize soft-tissue damage during extremity surgery.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Blood Flow Restriction Exercise: Considerations of Methodology, Application, and Safety
Patterson, S. D., Hughes, L., Warmington, S., Burr, J., Scott, B. R., Owens, J., Abe, T., Nielsen, J. L., Libardi, C. A., Laurentino, G., et al. (2019) · Frontiers in Physiology · doi:10.3389/fphys.2019.00533 · Cited by 917
Lixandrão, M. E., Ugrinowitsch, C., Berton, R., Vechin, F. C., Conceição, M. S., Damas, F., Libardi, C. A., & Roschel, H. (2018) · Sports Medicine · doi:10.1007/s40279-017-0795-y · Cited by 554
Potential safety issues with blood flow restriction training
Loenneke, J. P., Wilson, J. M., Wilson, G. J., Pujol, T. J., & Bemben, M. G. (2011) · Scandinavian Journal of Medicine & Science in Sports · doi:10.1111/j.1600-0838.2010.01290.x · Cited by 275
Type 1 Muscle Fiber Hypertrophy after Blood Flow-restricted Training in Powerlifters
BJØRNSEN, T., WERNBOM, M., KIRKETEIG, A., PAULSEN, G., SAMNØY, L., BÆKKEN, L., CAMERON-SMITH, D., BERNTSEN, S., & RAASTAD, T. (2019) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000001775 · Cited by 115
Metadata
- Authors
- Crenshaw, A. G., Hargens, A. R., Gershuni, D. H., & Rydevik, B.
- Venue
- Acta Orthopaedica Scandinavica
- Published
- 1988-01
- Volume
- 59
- Issue
- 4
- Pages
- 447-451
- ISSN
- 0001-6470 (ISSN-L)
- OpenAlex
- W2167419342
- Cited by
- 164
- References
- 0
- FWCI
- 1.35
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Wide tourniquet cuffs more effective at lower inflation pressures. https://app.cochat.ai/papers/10.3109/17453678809149401
- The paper
- Crenshaw, A. G., Hargens, A. R., Gershuni, D. H., & Rydevik, B. (1988). Wide tourniquet cuffs more effective at lower inflation pressures. Acta Orthopaedica Scandinavica. https://doi.org/10.3109/17453678809149401
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.