Hydroxyapatite coating enhances fixation of porous coated implants: A comparison in dogs between press fit and noninterference fit
Open accessThe DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
Intimate contact at the bone-porous surface interface is not always achievable in noncemented prosthetic implantation. We investigated the effect of hydroxyapatite (HA) coating on skeletal attachment in noninterference fit 4 weeks after implantation in 6 mature dogs. The push-out test of HA-coated implants surrounded by a 1-mm gap showed a twofold increased shear strength and fivefold increased shear stiffness compared with titanium alloy (Ti) coated implants. The fixation of Ti implants was reduced by two thirds when inserted in a gap as compared with press fit, whereas HA-coated implants in gap showed anchorage close to implants in press fit. Only minor differences were found between HA and Ti implants in press fit. Histomorphometric analysis showed a significant increase in bone in direct contact to HA-coated implant as compared with Ti implants inserted both in gap and press fit. The study indicates that tightness of surgical fit is an important factor for sufficient fixation of the implant. However, our results demonstrate that hydroxyapatite coating almost eliminates the negative influence of noninterference fit between bone and unloaded implant.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Calcium Phosphate Ceramics as Hard Tissue Prosthetics
JARCHO, M. (1981) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-198106000-00037 · Cited by 2,014
Plasma sprayed coatings of hydroxylapatite
De Groot, K., Geesink, R., Klein, C. P. A. T., & Serekian, P. (1987) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820211203 · Cited by 1,156 · cited 4×
“Recently, deposition of dense hydroxyapatite (HA) on titanium alloy (Ti) by plasma spraying technique has been shown to improve the HA-metal substrate interface shear strength (Gee-sink et al. 1988, de Groot et al. 1987, Thomas et al. 1987).”
BackgroundMethodInfluentialBiomechanical considerations in osseointegrated prostheses
Skalak, R. (1983) · The Journal of Prosthetic Dentistry · doi:10.1016/0022-3913(83)90361-x · Cited by 755 · cited 1×
“…of smooth-surfaced controls, skeletal fixation is increased, which again increases the demands on the osteocon-ductive effect of the relatively smooth surfaced hydroxyapatite implant; the opposite is true for smooth-surfaced controls (Skalak 1983, Carlsson et al. 1988b, Thomas and Cook 1985).”
BackgroundBonding of bone to apatite-coated implants
Geesink, R., de Groot, K., & Klein, C. (1988) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.70b1.2828374 · Cited by 537 · cited 1×
“HA coating provides earlier bone ingrowth compared with Ti (Geesink et al. 1988, de Groot et al. 1987, Saballe et al. 1989a, b, c, Thomas et al. 1987).”
BackgroundMechanical Properties and Composition of Cortical Bone
CARTER, D. R., & SPENGLER, D. M. (1978) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-197809000-00041 · Cited by 407
An evaluation of variables influencing implant fixation by direct bone apposition
Thomas, K. A., & Cook, S. D. (1985) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820190802 · Cited by 313 · cited 1×
“…of smooth-surfaced controls, skeletal fixation is increased, which again increases the demands on the osteocon-ductive effect of the relatively smooth surfaced hydroxyapatite implant; the opposite is true for smooth-surfaced controls (Skalak 1983, Carlsson et al. 1988b, Thomas and Cook 1985).”
BackgroundRemoval torques for polished and rough titanium implants.
Carlsson, L. V., Röstlund, T., Albrektsson, B., & Albrektsson, T. O. (1988) · PubMed · Cited by 298
Hydroxyapatite-Coated Porous Titanium for Use as an Orthopedic Biologic Attachment System
Cook, S. D., THOMAS, K. A., Kay, J. F., & Jarcho, M. (1988) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-198805000-00038 · Cited by 226 · cited 1×
“Using similar slight press fit (0.05 undersized holes) for insertion, Cook et al. (1988) found no increased anchorage of HA-coated transcortical implants compared with porous-coated Ti-alloy implants.”
BackgroundInfluentialOsseointegration of bone implants: A review of an alternative mode of fixation
Albrektsson, T. O., & Albrektsson, B. (1987) · Acta Orthopaedica Scandinavica · doi:10.3109/17453678709146401 · Cited by 223 · cited 1×
“Lack of optimal flatness after bone cutting, implant design deficiencies, and anatomic variations may result in gaps be-tween the implant surface and surrounding bone (Albrektsson and Albrektsson 1987, Larsen and Ryd 1990).”
BackgroundThe rate of bone ingrowth into porous metal
Camron, H. U., Pilliar, R. M., & Macnab, I. (1976) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820100210 · Cited by 208
Cited by
Søballe, K., Hansen, E. S., B.‐Rasmussen, H., Jørgensen, P. H., & Bünger, C. (1992) · Journal of Orthopaedic Research · doi:10.1002/jor.1100100216 · Cited by 506
Self-citationKilpadi, K. L., Chang, P.-L., & Bellis, S. L. (2001) · Journal of Biomedical Materials Research · doi:10.1002/1097-4636(200111)57:2<258::aid-jbm1166>3.0.co;2-r · Cited by 419
Anchorage of TiO2‐blasted, HA‐coated, and machined implants: An experimental study with rabbits
Gotfredson, K., Wennerberg, A., Johansson, C., Skovgaard, L. T., & Hjørting‐Hansen, E. (1995) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820291009 · Cited by 284
Current Concepts in Orthopaedic Biomaterials and Implant Fixation
FRIEDMAN, R. J., BLACK, J., GALANTE, J. O., JACOBS, J. J., & SKINNER, H. B. (1993) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199307000-00017 · Cited by 210
In vivo study of the effect of RGD treatment on bone ongrowth on press-fit titanium alloy implants
Elmengaard, B., Bechtold, J. E., & Søballe, K. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.09.039 · Cited by 184
Self-citationDhert, W. J. A., Klein, C. P. A. T., Jansen, J. A., van der Velde, E. A., Vriesde, R. C., Rozing, P. M., & de Groot, K. (1993) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820270116 · Cited by 179
3D printing and modelling of customized implants and surgical guides for non-human primates.
Chen, X., Possel, J. K., Wacongne, C., van Ham, A. F., Klink, P. C., & Roelfsema, P. R. (2017) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2017.05.013 · Cited by 106
“Commercial orthopaedic and dental implants are coated with HA granules, to promote osseointegration between the bone and the implant (Søballe et al., 1990; Cook et al., 1992; Lanz et al., 2013; Raphel et al., 2016). bottom surfaces of our implants were plasma sprayed with HA by the company Medicoat…”
Metadata
- Authors
- Søballe, K., Hansen, E. S., Brockstedt-Rasmussen, H., Pedersen, C. M., & Bünger, C.
- Venue
- Acta Orthopaedica Scandinavica
- Published
- 1990-01
- Volume
- 61
- Issue
- 4
- Pages
- 299-306
- ISSN
- 0001-6470 (ISSN-L)
- OpenAlex
- W2069920951
- Cited by
- 197
- References
- 12
- FWCI
- 10.33
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.