Reliability and Feasibility of Methods to Quantitatively Assess Peripheral Edema
Open accessThe DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: To evaluate methods to assess peripheral edema for reliability, feasibility and correlation with the classic clinical assessment of pitting edema. DESIGN: Cross-sectional observational study. SETTING: Large primary care clinic in Marshfield, Wisconsin, USA. PARTICIPANTS: Convenience sample of 20 patients with type 2 diabetes and a range of edema severity, including patients without edema. METHODS: Eight methods of edema assessment were evaluated: (1) clinical assessment of pit depth and recovery at three locations, (2) patient questionnaire, (3) ankle circumference, (4) figure-of-eight (ankle circumference using eight ankle/foot landmarks), (5) edema tester (plastic card with holes of varying size pressed to the ankle with a blood pressure cuff), (6) modified edema tester (edema tester with bumps), (7) indirect leg volume (by series of ankle/leg circumferences), and (8) foot/ankle volumetry by water displacement. Patients were evaluated independently by three nurse examiners. RESULTS: Water displacement and ankle circumference had high inter-examiner agreement (intraclass correlation coefficient 0.93, 0.96 right; 0.97, 0.97 left). Agreement was inconsistent for figure-of-eight (0.64, 0.86), moderate for indirect leg volume (0.53, 0.66), and low for clinical assessments at all locations. Agreement was low for the edema testers but varied by the pressure administered. Correlation with the classic, subjective clinical assessment was good for the nurse-performed assessments and patient questionnaire. Ankle circumference and patient questionnaires each took 1 minute to complete. Other tools took >5 minutes to complete. CONCLUSIONS: Water displacement and ankle circumference showed excellent reliability; however, water displacement is a time-consuming measure and may pose implementation challenges in the clinical and clinical trial environments. Patient-reported level and frequency of edema, based on an unvalidated questionnaire, was generally well correlated with the physician assessment of edema severity and may prove to be another reliable and accurate method of assessing edema. Additional study is needed to evaluate the validity and responsiveness of these methods.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Intraclass correlations: Uses in assessing rater reliability.
Shrout, P. E., & Fleiss, J. L. (1979) · Psychological Bulletin · doi:10.1037/0033-2909.86.2.420 · Cited by 24,532
Deyo, R. A., Diehr, P., & Patrick, D. L. (1991) · Controlled Clinical Trials · doi:10.1016/s0197-2456(05)80019-4 · Cited by 1,364 · cited 1×
“75 are considered favorable.(31) Although precision was limited with only 20 patients evaluated, it was estimated that if good agreement exists between examiners, 20 patients would be adequate to allow estimation of ICC within ±0.”
BackgroundThe clinical impact of iliac venous stents in the management of chronic venous insufficiency
RAJU, S., OWEN, S., & NEGLEN, P. (2002) · Journal of Vascular Surgery · doi:10.1016/s0741-5214(02)47345-4 · Cited by 229
Kaulesar Sukul, D. M. K. S., den Hoed, P. T., Johannes, E. J., van Dolder, R., & Benda, E. (1993) · Journal of Biomedical Engineering · doi:10.1016/0141-5425(93)90062-4 · Cited by 225 · cited 3×
“Indirect Measure of Leg Volume Leg volume was calculated indirectly using the disk model.(12,13) A series of ankle and leg circumferences was used to calculate the volume of each cross-section in millimeters.”
BackgroundMethodApproach to Leg Edema of Unclear Etiology
Ely, J. W., Osheroff, J. A., Chambliss, M. L., & Ebell, M. H. (2006) · The Journal of the American Board of Family Medicine · doi:10.3122/jabfm.19.2.148 · Cited by 217 · cited 3×
“Methods: Eight methods of edema assessment were evaluated: (1) clinical assessment of pit depth and recovery at three locations, (2) patient questionnaire, (3) ankle circumference, (4) figure-of-eight (ankle circumference using eight ankle/foot landmarks), (5) edema tester (plastic card with holes of varying size pres…”
MethodSunder, M., Chang, A. R., & Henry, R. R. (2003) · Endocrine Practice · doi:10.4158/ep.9.5.406 · Cited by 209 · cited 3×
“Methods: Eight methods of edema assessment were evaluated: (1) clinical assessment of pit depth and recovery at three locations, (2) patient questionnaire, (3) ankle circumference, (4) figure-of-eight (ankle circumference using eight ankle/foot landmarks), (5) edema tester (plastic card with holes of varying size pres…”
MethodVasodilatory edema: A common side effect of antihypertensive therapy
Messerli, F. H. (2002) · Current Cardiology Reports · doi:10.1007/s11886-002-0110-9 · Cited by 167
Malacco, E., Varì, N. A., Capuano, V., Spagnuolo, V., Borgnino, C., Palatini, P., & Val-Syst Investigators (2003) · Clinical Therapeutics · doi:10.1016/s0149-2918(03)80332-6 · Cited by 103
Etiology and diagnosis of bilateral leg edema in primary care
Blankfield, R. P., Finkelhor, R. S., Alexander, J. J., Flocke, S. A., Jl, M., Goodwin, M. A., & Zyzanski, S. J. (1998) · The American Journal of Medicine · doi:10.1016/s0002-9343(98)00235-6 · Cited by 83
Criterion-Related Validity of the Figure-of-Eight Method of Measuring Ankle Edema
Mawdsley, R. H., Hoy, D. K., & Erwin, P. M. (2000) · Journal of Orthopaedic and Sports Physical Therapy · doi:10.2519/jospt.2000.30.3.149 · Cited by 79 · cited 2×
“99.(16,26,32) The high reliability of water-displacement volumetry observed in the current study is similar to that seen previously.”
MethodResultThe edematogenic properties of insulin
Kalambokis, G. N., Tsatsoulis, A. A., & Tsianos, E. V. (2004) · American Journal of Kidney Diseases · doi:10.1053/j.ajkd.2004.06.025 · Cited by 74
Calcium antagonists in hypertension: from hemodynamics to outcomes
Messerli, F. H. (2002) · American Journal of Hypertension · doi:10.1016/s0895-7061(02)02950-3 · Cited by 57
Peripheral Edema in the Sleep Apnea/Hypopnea Syndrome
(1991) · Sleep · doi:10.1093/sleep/14.4.354 · Cited by 36
The edema tester in the evaluation of swollen limbs in venous and lymphatic disease.
Mr, C., Belcaro, G. V., An, N., et al. (1999) · PubMed · Cited by 27
Approach to diagnosing lower extremity edema
Yale, S. H., & Mazza, J. J. (2001) · Comprehensive Therapy · doi:10.1007/s12019-001-0021-5 · Cited by 27 · cited 3×
“Methods: Eight methods of edema assessment were evaluated: (1) clinical assessment of pit depth and recovery at three locations, (2) patient questionnaire, (3) ankle circumference, (4) figure-of-eight (ankle circumference using eight ankle/foot landmarks), (5) edema tester (plastic card with holes of varying size pres…”
MethodSelf-citationVolumetry in the evaluation of swelling in the ankle and foot.
Nilsson, S., & Gb, H. (1981) · PubMed · Cited by 19
Peripheral Oedema Related to Quetiapine Therapy
Rozzini, L., Ghianda, D., Chilovi, B. V., et al. (2005) · Drugs & Aging · doi:10.2165/00002512-200522020-00007 · Cited by 13 · cited 3×
“Methods: Eight methods of edema assessment were evaluated: (1) clinical assessment of pit depth and recovery at three locations, (2) patient questionnaire, (3) ankle circumference, (4) figure-of-eight (ankle circumference using eight ankle/foot landmarks), (5) edema tester (plastic card with holes of varying size pres…”
MethodUnilateral Edema Due to a Thiazolidinedione
Bell, D. S. H. (2003) · Diabetes Care · doi:10.2337/diacare.26.9.2700 · Cited by 11 · cited 3×
“Methods: Eight methods of edema assessment were evaluated: (1) clinical assessment of pit depth and recovery at three locations, (2) patient questionnaire, (3) ankle circumference, (4) figure-of-eight (ankle circumference using eight ankle/foot landmarks), (5) edema tester (plastic card with holes of varying size pres…”
Method
Cited by
6-Month Outcomes of Tricuspid Valve Reconstruction for Patients With Severe Tricuspid Regurgitation
Nickenig, G., Weber, M., Schueler, R., Hausleiter, J., Näbauer, M., von Bardeleben, R. S., Sotiriou, E., Schäfer, U., Deuschl, F., Kuck, K.-H., et al. (2019) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2019.01.062 · Cited by 224
Artificial intelligence-enhanced patient evaluation: bridging art and science
Oikonomou, E. K., & Khera, R. (2024) · European Heart Journal · doi:10.1093/eurheartj/ehae415 · Cited by 34
Metadata
- Authors
- Brodovicz, K. G., McNaughton, K., Uemura, N., Meininger, G., Girman, C. J., & Yale, S. H.
- Venue
- Clinical Medicine & Research
- Publisher
- Marshfield Clinic Research Institute
- Published
- 2009-02-26
- Volume
- 7
- Issue
- 1-2
- Pages
- 21-31
- ISSN
- 1539-4182 (ISSN-L)
- 1554-6179
- OpenAlex
- W2047742026
- Cited by
- 181
- References
- 18
- FWCI
- 4.00
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.