Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 225

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Direct and indirect methods for the quantification of leg volume: comparison between water displacement volumetry, the disk model method and the frustum sign model method, using the correlation coefficient and the limits of agreement

Open access
Kaulesar Sukul, D.M.K.S., den Hoed, P.T., Johannes, E.J., van Dolder, R., Benda, E.·1993·Journal of Biomedical Engineering

Abstract

Volume changes can be measured either directly by water-displacement volumetry or by various indirect methods in which calculation of the volume is based on circumference measurements. The aim of the present study was to determine the most appropriate indirect method for lower leg volume calculation using water displacement volumetry as a 'golden standard'. For 20 male volunteers, age range: 20-35 years, the volume of both lower legs was determined directly by water-displacement volumetry, and indirectly by the frustum sign model method and the disc model method. Calculation of the correlation coefficient and the limits of agreement showed that water-displacement volumetry and the disc model method are interchangeable (r = +0.99, mean +/- 2s = -45 +/- 78 ml), whereas this does not hold for the frustum sign model (r = +0.93, mean +/- 2s = 521 +/- 238 ml). In the clinical situation volume measurement can be valuable for monitoring of the severity of oedema or haematoma occurrence after surgery or severe trauma. This non-invasive diagnostic aid may be a valuable adjuvant means of diagnosis for several volume dependent disorders of the extremities.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/0141-5425(93)90062-4

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 225

Metadata

Authors
Kaulesar Sukul, D. M. K. S., den Hoed, P. T., Johannes, E. J., van Dolder, R., & Benda, E.
Venue
Journal of Biomedical Engineering
Published
1993-11-01
Volume
15
Issue
6
Pages
477-480
ISSN
0141-5425 (ISSN-L)
OpenAlex
W2101395499
Cited by
225
References
1
FWCI
0.83
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Direct and indirect methods for the quantification of leg volume: comparison between water displacement volumetry, the disk model method and the frustum sign model method, using the correlation coefficient and the limits of agreement. https://app.cochat.ai/papers/10.1016/0141-5425(93)90062-4
The paper
Kaulesar Sukul, D. M. K. S., den Hoed, P. T., Johannes, E. J., van Dolder, R., & Benda, E. (1993). Direct and indirect methods for the quantification of leg volume: comparison between water displacement volumetry, the disk model method and the frustum sign model method, using the correlation coefficient and the limits of agreement. Journal of Biomedical Engineering. https://doi.org/10.1016/0141-5425(93)90062-4

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.