Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 402

The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.

Field guide for collecting and processing stream-water samples for the National Water-Quality Assessment Program

Open access
Shelton, Larry R.·1994·Open-File Report

Abstract

Introduction 1 Overview of water-column study design 3 Preparation for sample collection 6 Site selection 6 Sampling equipment 6 Hand-held samplers 10 Suspended samplers 10 D-77 TM 10 D-77 bag 10 Under ice 10 Weighted bottle 11 Support equipment 11 Processing equipment 11 Processing and preservation chambers 11 Sample splitters 12 Filter systems 12 Equipment cleaning 13 Inorganic constituents and organic compounds 13 Organic carbon 13 Collection methods 14 Equal-width-increment sampling 16 Equal-discharge-increment sampling 16 Nonstandard sampling 16 Organic-carbon sampling 16 Low-flow sampling 17 High-flow sampling 17 Sampling frozen streams 17 Automatic samplers 17 Sample processing 17 Splitting 18 Sediment sample 20 Filtration 20 Inorganic constituents 20 Organic carbons 21 Organic compounds 23 Changing filter paper 24 Cartridge processing 24 Preservation 25 Distribution 26 Field analyses 27 Temperature 27 Specific conductance 28 Calibration 28 Measurement 29 pH 29 Calibration 30 Measurement 30 Contents Field analyses-Continued Alkalinity, bicarbonate, and carbonate 31 Fixed end-point method 31 Incremental method 31 Dissolved oxygen 33 Probe maintenance 33 Calibration 34 Barometer calibration 34 Air-calibration chamber in water 34 Air-saturated water 36 Measurement 37 Documentation 37 Quality assurance and quality control 39 Field blanks 39 Replicates 39 Field-matrix spikes 39 References cited 40 Appendix A. Selected technical memorandums 41 Appendix B. Selected internal communications 42 FIGURES 1. Suggested water-quality samplers for various stream regimes 15 2. Example of form for recording surface-water quality field notes 38 TABLES Conversion Factors, Vertical Datum, Abbreviations, and Acronyms V Abbreviations cm, centimeter g/L, gram per liter L, liter |jL, microliter jam, micrometer jiS/cm, microsiemens per centimeter at 25 degrees Celsius mg/L, milligram per liter mg/|jL, milligram per microliter mL, milliliter mL/min, milliliter per minute mm, millimeter DIW deionized water DOC dissolved organic carbon EDI equal-discharge increment EWI equal-width increment FA filtered acidified FC filtered chilled FU filtered untreated GCMS gas chromatography/mass spectrometer HPLC high-pressure liquid chromatography N normal OCALA Quality Water Service Unit, USGS, Ocala, Florida PPB parts per billion PVC polyvinyl chloride RC raw (unfiltered) chilled RU raw (unfiltered) untreated SOC suspended-organic carbon SPE solid-phase extraction TOC toxic organic compounds VOC volatile organic compound

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3133/ofr94455

Cites

12 of 12 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 12 references

Cited by

See all 402

Metadata

Authors
Shelton, L. R.
Venue
Open-File Report
Published
1994
ISSN
  • 0196-1497 (ISSN-L)
  • 2331-1258
OpenAlex
W1577541066
Cited by
402
References
12
Type
report
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Field guide for collecting and processing stream-water samples for the National Water-Quality Assessment Program. https://app.cochat.ai/papers/10.3133/ofr94455
The paper
Shelton, L. R. (1994). Field guide for collecting and processing stream-water samples for the National Water-Quality Assessment Program. Open-File Report. https://doi.org/10.3133/ofr94455

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.