Analysis of Sudan I in Food by QuEChERS Combined with Ultrasound-assisted Dispersive Liquid-liquid Microextraction with Solidification of Floating Organic Drop (UADLLME-SFO) Prior to HPLC-PAD
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
A convenient and environmentally friendly method was developed for extraction and enrich of Sudan I from tomato sauce and chilli products. The method is based on an ultrasound-assisted dispersive liquid-liquid microextraction with solidification of floating organic drop (UADLLME-SFO) after a preliminary QuEChERS procedure, which was followed by high performance liquid chromatography with photodiode array detection (HPLC-PAD). The several parameters involved in the UADLLME-SFO step was optimized. The optimal variables obtained were 30 µL of 1-dodecanol as the extraction solvent, 1.0 mL of acetone as disperse solvent, ultrasonic irritation for 15 min, and no salt addition. Under the optimum conditions, the limit of detection for Sudan I was as low as 1.5 µg kg−1. The recoveries obtained was between 79% and 92% (RSD, 4.8% – 7.1%, n = 7). The proposed method was successfully applied to the determination of Sudan I in four kinds of real samples.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Evolution of dispersive liquid–liquid microextraction method
Rezaee, M., Yamini, Y., & Faraji, M. (2010) · Journal of Chromatography A · doi:10.1016/j.chroma.2009.11.088 · Cited by 971 · cited 4×
“1 (Rezaee et al., 2010).”
BackgroundMethodInfluentialDetermination of pesticide residues in food matrices using the QuEChERS methodology
Wilkowska, A., & Biziuk, M. (2011) · Food Chemistry · doi:10.1016/j.foodchem.2010.09.094 · Cited by 627 · cited 2×
“After standard solution additions, the mixture was irradiated with ultrasound for 20 min at room temperature, and 4 g of anhydrous MgSO4 and 1 g NaCl were added (Wilkowska and Biziuk, 2011).”
Method
Cited by
Mansour, F. R., & Danielson, N. D. (2017) · Talanta · doi:10.1016/j.talanta.2017.03.084 · Cited by 178
Ten years of dispersive liquid–liquid microextraction and derived techniques
Campillo, N., Viñas, P., Šandrejová, J., & Andruch, V. (2017) · Applied Spectroscopy Reviews · doi:10.1080/05704928.2016.1224240 · Cited by 102
Sivrikaya Ozak, S., & Yılmaz, Y. (2020) · Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy · doi:10.1016/j.saa.2020.118353 · Cited by 51
Ozalp, O., & Soylak, M. (2023) · Analytical Letters · doi:10.1080/00032719.2023.2175212 · Cited by 28
Metadata
- Authors
- He, X., Chen, Y., Li, H., Zou, T., Huang, M., Li, H., & Xia, E.
- Venue
- Food Science and Technology Research
- Published
- 2015
- Volume
- 21
- Issue
- 5
- Pages
- 659-664
- ISSN
- 1344-6606 (ISSN-L)
- 1881-3984
- OpenAlex
- W2396965271
- Cited by
- 15
- References
- 2
- FWCI
- 1.00
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Analysis of Sudan I in Food by QuEChERS Combined with Ultrasound-assisted Dispersive Liquid-liquid Microextraction with Solidification of Floating Organic Drop (UADLLME-SFO) Prior to HPLC-PAD. https://app.cochat.ai/papers/10.3136/fstr.21.659
- The paper
- He, X., Chen, Y., Li, H., Zou, T., Huang, M., Li, H., & Xia, E. (2015). Analysis of Sudan I in Food by QuEChERS Combined with Ultrasound-assisted Dispersive Liquid-liquid Microextraction with Solidification of Floating Organic Drop (UADLLME-SFO) Prior to HPLC-PAD. Food Science and Technology Research. https://doi.org/10.3136/fstr.21.659
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.