Corrosion Testing of HVOF Coatings in High Temperature Environments for Biomass Applications
Abstract
Abstract This paper reports the corrosion behaviour of coatings deposited by high velocity oxy-fuel (HVOF) spraying and representative boiler substrate alloys in simulated high temperature biomass combustion conditions. Four commercially available oxidation resistant Ni alloy coating materials were selected: NiCrBSiFe, alloy 718, alloy 625 and alloy C-276. These were sprayed onto P91 substrates using a JP5000 spray system. The corrosion performance of the coatings varied when tested at 525, 625 and 725°C in K2SO4- KCl and gaseous HCl-H2O-O2 containing environments. Alloy 625, NiCrBSiFe and alloy 718 coatings performed better than alloy C-276 coating at 725°C, which had very little corrosion resistance resulting in degradation similar to uncoated P91. Alloy 625 coatings provided good protection from corrosion at 725°C, with the performance being comparable to wrought alloy 625, with significantly less attack of the substrate than uncoated P91. Alloy 625 performs best of these coating materials, with an overall ranking at 725°C as follows: alloy 625 > NiCrBSiFe > alloy 718 >> alloy C-276. Although alloy C-276 coatings performed poorly in the corrosion test environment at ~725°C, at lower temperatures (i.e. below the eutectic temperature of the salt mixture) it outperforms the other coating types studied.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Addition of an inhibitor such as ZrO2 to a boiler environment such as Na2SO4-60% V2O5 can help decrease the corrosion rate of superalloys at high temperature.
“Goyal et al. [121] confirm that the addition of inhibitor such as ZrO 2 to boiler environment such as Na 2 SO 4 -60% V 2 O 5 can help in decreasing the corrosion rate of superalloys at high temperature.”
From Corrosion Problems in Incinerators and Biomass-Fuel-Fired Boilers (2014) · cites this paper as [121]
Cites
Still being checked.
Cited by
Sorted by citations
Corrosion Problems in Incinerators and Biomass-Fuel-Fired Boilers
Mudgal, D., Singh, S., & Prakash, S. (2014) · International Journal of Corrosion · doi:10.1155/2014/505306 · Cited by 56 · see citing works
Bilayer Coating Systems: Functional Interlayers and Top Layers for Enhanced Performance
Shapagina, N. A., & Владимирович, Д. В. (2025) · Materials · doi:10.3390/ma18225217 · Cited by 5 · see citing works
Mitigation of Biomass-Induced Corrosion of Superheater Tubes Using Thermal Spray Coatings
Harvey, D., Paul, S., Riley, M., & Barnett, R. (2013) · NACE CORROSION Conference · doi:10.5006/c2013-02625 · Cited by 1 · see citing works
Self-citation
- Authors
- Paul, S., & Harvey, M. D. F.
- Affiliations
- TWI (United Kingdom) (GB)
- ORCID
- Paul, S.
- Venue
- International Thermal Spray Conference
- Publisher
- ASM International
- Published
- 2012-05-21
- Volume
- 83720
- Pages
- 184-189
- ISSN
- 2768-1491 (ISSN-L)
- 2768-1505
- OpenAlex
- W4313825236
- Cited by
- 2
- References
- 0
- Citations by year
- 2025: 1 · 2013: 1
- FWCI
- 0.60
- Type
- conference paper
- Language
- en
- Open access
- closed
- Locations
- Thermal spray (publishedVersion)
- Topics
- Physical Sciences › Engineering › Aerospace Engineering › High-Temperature Coating Behaviors
- Physical Sciences › Engineering › Mechanical Engineering › High Temperature Alloys and Creep
- Physical Sciences › Engineering › Mechanical Engineering › Surface Treatment and Coatings
- Keywords
- HVOF coatings, corrosion resistance, biomass combustion, high-temperature corrosion, Inconel 625, Inconel 718, Alloy C-276, P91 steel, salt corrosion
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review