Surface Micromachined Z-Axis Vibratory Rate Gyroscope

Open access
Clark, W.A., Horowitz, R., Howe, R.T.·1996·1996 Solid-State, Actuators, and Microsystems Workshop Technical Digest

Abstract

We have designed and tested the first polysilicon surface micromachined vibratory rate gyroscope that is sensitive to angular rotation about an axis normal to the plane of the silicon chip, the Z-axis.The Analog Devices, Inc. BiMEMS technology was used to fabricate the gyroscope, which has as a demonstrated minimum detectable signal of 1 deg/sec/Hz 112 with performance projected to improve to 0.1 deg/sec/Hz 112 in a second-generation BiMEMS design.Our design makes use of electrostatics to improve perfor mance considerably.Electrostatic frequency tuning of the sense mode is used to enhance sensitivity.Quadrature error due to asym metries in the vibrating structure is nulled by detecting the resulting motion and applying electrostatic forces by modifying voltages on the interdigitated sense comb fingers to cancel error precisely.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.31438/trf.hh1996.64

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 206

Metadata

Authors
Clark, W. A., Horowitz, R., & Howe, R. T.
Venue
1996 Solid-State, Actuators, and Microsystems Workshop Technical Digest
Published
1996-06-03
Pages
283-287
OpenAlex
W3120346404
Cited by
206
References
0
FWCI
24.94
Type
conference paper
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Surface Micromachined Z-Axis Vibratory Rate Gyroscope. https://app.cochat.ai/papers/10.31438/trf.hh1996.64
The paper
Clark, W. A., Horowitz, R., & Howe, R. T. (1996). Surface Micromachined Z-Axis Vibratory Rate Gyroscope. 1996 Solid-State, Actuators, and Microsystems Workshop Technical Digest. https://doi.org/10.31438/trf.hh1996.64

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.