An Evaluation of the Accuracy and Precision of a Stand-Alone Submersible Continuous Ruminal pH Measurement System
Open accessThe DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
The objectives of this study were 1) to develop and evaluate the accuracy and precision of a new stand-alone submersible continuous ruminal pH measurement system called the Lethbridge Research Centre ruminal pH measurement system (LRCpH; Experiment 1); 2) to establish the accuracy and precision of a well-documented, previously used continuous indwelling ruminal pH system (CIpH) to ensure that the new system (LRCpH) was as accurate and precise as the previous system (CIpH; Experiment 2); and 3) to determine the required frequency for pH electrode standardization by comparing baseline millivolt readings of pH electrodes in pH buffers 4 and 7 after 0, 24, 48, and 72 h of ruminal incubation (Experiment 3). In Experiment 1, 6 pregnant Holstein heifers, 3 lactating, primiparous Holstein cows, and 2 Black Angus heifers were used. All experimental animals were fitted with permanent ruminal cannulas. In Experiment 2, the 3 cannulated, lactating, primiparous Holstein cows were used. In both experiments, ruminal pH was determined continuously using indwelling pH electrodes. Subsequently, mean pH values were then compared with ruminal pH values obtained using spot samples of ruminal fluid (MANpH) obtained at the same time. A correlation coefficient accounting for repeated measures was calculated and results were used to calculate the concordance correlation to examine the relationships between the LRCpH-derived values and MANpH, and the CIpH-derived values and MANpH. In Experiment 3, the 6 pregnant Holstein heifers were used along with 6 new submersible pH electrodes. In Experiments 1 and 2, the comparison of the LRCpH output (1- and 5-min averages) to MANpH had higher correlation coefficients after accounting for repeated measures (0.98 and 0.97 for 1- and 5-min averages, respectively) and concordance correlation coefficients (0.96 and 0.97 for 1- and 5-min averages, respectively) than the comparison of CIpH to MANpH (0.88 and 0.87, correlation coefficient and concordance correlation coefficient, respectively). The concordance correlation analysis indicated that the ruminal pH data for LRCpH (1- and 5-min averages) vs. MANpH had location shifts that were smaller than those of the CIpH vs. MANpH. However, the scale shift was similar between the LRCpH and the CIpH. The plotted data from both systems closely resembled the line y = x, indicating that both systems were accurate and precise. In Experiment 3, changes in baseline millivolt readings for pH readings after 24, 48, or 72 h of ruminal incubation were not significantly different than zero, indicating that daily standardization of new electrodes was not essential. Results from this study indicate that the LRCpH system can accurately and precisely measure ruminal pH; thus, it provides increased opportunity for researchers to measure ruminal pH and the occurrence of ruminal acidosis in unrestrained cattle.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A concordance correlation coefficient to evaluate reproducibility.
Lin, L. I.-K. (1989) · Biometrics · doi:10.2307/2532051 · Cited by 8,785
Owens, F. N., Secrist, D. S., Hill, W. J., & Gill, D. R. (1998) · Journal of Animal Science · doi:10.2527/1998.761275x · Cited by 1,382
Bovine acidosis: Implications on laminitis
Nocek, J. E. (1997) · Journal of Dairy Science · doi:10.3168/jds.s0022-0302(97)76026-0 · Cited by 950 · cited 2×
“Ruminal acidosis is a common problem in modern ruminant production, particularly in high-producing dairy herds (Nocek, 1997) as the demands for increased milk production have resulted in high-grain, low-fiber diets being the norm to maximize energy intake.”
A Note On "A Concordance Correlation Coefficient to Evaluate Reproducibility"
Nickerson, C. A. E. (1997) · Biometrics · doi:10.2307/2533516 · Cited by 510
(1997) · Technometrics · doi:10.1080/00401706.1997.10485461 · Cited by 457
Assay Validation Using the Concordance Correlation Coefficient
Lin, L. I.-K. (1992) · Biometrics · doi:10.2307/2532314 · Cited by 419
Comparison of Techniques for Measurement of Rumen pH in Lactating Dairy Cows
Duffield, T., Plaizier, J. C., Fairfield, A., Bagg, R., Vessie, G., Dick, P., Wilson, J., Aramini, J., & McBride, B. (2004) · Journal of Dairy Science · doi:10.3168/jds.s0022-0302(04)73142-2 · Cited by 351
Beauchemin, K. A., & Yang, W. Z. (2005) · Journal of Dairy Science · doi:10.3168/jds.s0022-0302(05)72888-5 · Cited by 298
Self-citationBevans, D. W., Beauchemin, K. A., Schwartzkopf-Genswein, K. S., McKinnon, J. J., & McAllister, T. A. (2005) · Journal of Animal Science · doi:10.2527/2005.8351116x · Cited by 280
Self-citationDiagnostic Methods for the Detection of Subacute Ruminal Acidosis in Dairy Cows
Garrett, E. F., Pereira, M. N., Nordlund, K. V., Armentano, L. E., Goodger, W. J., & Oetzel, G. R. (1999) · Journal of Dairy Science · doi:10.3168/jds.s0022-0302(99)75340-3 · Cited by 264
Cited by
Ruminal Acidosis in Beef Cattle: The Current Microbiological and Nutritional Outlook
Nagaraja, T. G., & Titgemeyer, E. C. (2007) · Journal of Dairy Science · doi:10.3168/jds.2006-478 · Cited by 873
RUMINANT NUTRITION SYMPOSIUM: Role of fermentation acid absorption in the regulation of ruminal pH12
Aschenbach, J. R., Penner, G. B., Stumpff, F., & Gäbel, G. (2011) · Journal of Animal Science · doi:10.2527/jas.2010-3301 · Cited by 487
Self-citationPetri, R. M., Schwaiger, T., Penner, G. B., Beauchemin, K. A., Forster, R. J., McKinnon, J. J., & McAllister, T. A. (2013) · PLoS ONE · doi:10.1371/journal.pone.0083424 · Cited by 408
Self-citationThe monitoring, prevention and treatment of sub-acute ruminal acidosis (SARA): A review
Enemark, J. M. D. (2008) · The Veterinary Journal · doi:10.1016/j.tvjl.2007.12.021 · Cited by 400
Severity of ruminal acidosis in primiparous holstein cows during the periparturient period
Penner, G. B., Beauchemin, K. A., & Mutsvangwa, T. (2007) · Journal of Dairy Science · doi:10.3168/jds.s0022-0302(07)72638-3 · Cited by 245
Self-citationYang, W. Z., Benchaar, C., Ametaj, B. N., Chaves, A. V., He, M. L., & McAllister, T. A. (2007) · Journal of Dairy Science · doi:10.3168/jds.2007-0369 · Cited by 228
“Ruminal pH was monitored continuously for 72 h during d 13 to 16 of each experimental period as described by Penner et al. (2006).”
MethodPetri, R. M., Schwaiger, T., Penner, G. B., Beauchemin, K. A., Forster, R. J., McKinnon, J. J., & McAllister, T. A. (2013) · Applied and Environmental Microbiology · doi:10.1128/aem.03983-12 · Cited by 218
Self-citationDeVries, T. J., Dohme, F., & Beauchemin, K. A. (2008) · Journal of Dairy Science · doi:10.3168/jds.2008-1347 · Cited by 209
“Ruminal pH was continuously measured from d 1 to 9 of each experimental period using the Lethbridge Research Centre Ruminal pH Measurement System (LRCpH; Dascor, Escondido, CA) as described in detail by Penner et al. (2006). Ruminal pH readings were taken every 30 s.”
MethodSelf-citationDschaak, C. M., Williams, C. M., Holt, M. S., Eun, J.-S., Young, A. J., & Min, B. R. (2011) · Journal of Dairy Science · doi:10.3168/jds.2010-3818 · Cited by 197
“Ruminal pH was continuously measured for 2 consecutive days starting on d 18 using the Lethbridge Research Centre Ruminal pH Measurement System (LRCpH; Dascor, Escondido, CA) as described by Penner et al. (2006).”
MethodPenner, G. B., Taniguchi, M., Guan, L. L., Beauchemin, K. A., & Oba, M. (2009) · Journal of Dairy Science · doi:10.3168/jds.2008-1716 · Cited by 172
“surement System (Dascor, Escondido, CA) as described previously by Penner et al. (2006a). Daily minimum,”
BackgroundMethodInfluentialSelf-citationAboagye, I. A., Oba, M., Koenig, K. M., Zhao, G. Y., & Beauchemin, K. A. (2019) · Journal of Animal Science · doi:10.1093/jas/skz101 · Cited by 84
Self-citationImpact of severity of ruminal acidosis on feed-sorting behaviour of beef cattle
DeVries, T. J., Schwaiger, T., Beauchemin, K. A., & Penner, G. B. (2014) · Animal Production Science · doi:10.1071/an14227 · Cited by 35
Self-citation
Metadata
- Authors
- Penner, G. B., Beauchemin, K. A., & Mutsvangwa, T.
- Venue
- Journal of Dairy Science
- Publisher
- American Dairy Science Association
- Published
- 2006-06
- Volume
- 89
- Issue
- 6
- Pages
- 2132-2140
- ISSN
- 0022-0302 (ISSN-L)
- OpenAlex
- W2139087046
- Cited by
- 300
- References
- 18
- FWCI
- 18.05
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.