CoChat

Determination of Clotting Power of Milk Clotting Enzymes

Open access
Kopelman, I.J., Cogan, U. · 1976 · Journal of Dairy Science
Cited by 57

The DOI matches its Crossref record.

Abstract

A simple objective method employing a rotational type viscometer is proposed for determination of the clotting power of milk-curdling enzymes through continuous monitoring of the viscosity of a milk-enzyme system.A characteristic viscosity versus time pattern is a constant viscosity base line followed by a steep linear increase in viscosity when coagulation sets in.The coagulation point is defined as the intersection of the two straight lines of such a plot.Linear calibration curves relating enzyme concentration with coagulation point were obtained with correlation coefficients larger than .996.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3168/jds.s0022-0302(76)84183-5

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 57

Metadata

Authors
Kopelman, I. J., & Cogan, U.
Venue
Journal of Dairy Science
Published
1976-02
Volume
59
Issue
2
Pages
196-199
ISSN
0022-0302 (ISSN-L)
OpenAlex
W1965775912
Cited by
57
References
0
FWCI
2.40
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Determination of Clotting Power of Milk Clotting Enzymes. https://app.cochat.ai/papers/10.3168/jds.s0022-0302(76)84183-5
The paper
Kopelman, I. J., & Cogan, U. (1976). Determination of Clotting Power of Milk Clotting Enzymes. Journal of Dairy Science. https://doi.org/10.3168/jds.s0022-0302(76)84183-5

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.