The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Near-Infrared Spectroscopy for Dairy Management: Measurement of Unhomogenized Milk Composition
Open accessAbstract
The potential of near-infrared spectroscopy to measure fat, total protein, and lactose contents of unhomogenized milk was studied for use in dairy management, as a new tool for on-line milk analysis in the process of milking. Influence of the spectral region, sample thickness, and spectral data treatment on the accuracy of determination was investigated. Transmittance spectra of 258 milk samples, collected at different stages of the milking process, were obtained with a spectrophotometer (NIRSystems 6500; FOSS-NIRSystems, Silver Spring, MD) in the wavelength range from 400 to 2500 nm with sample thicknesses of 1 mm, 4 mm, and 10 mm. The spectral region and sample thickness were found to be significant factors for milk fat and total protein determination but not the lactose determination. The best accuracy was obtained with the 1100 to 2400 nm region, 1-mm sample thickness, and the first derivative data transformation. For the spectral region from 700 to 1100 nm, close accuracy was obtained for fat with a 10-mm sample and for total protein with a 1-mm sample thickness. The sample thickness did not change significantly the accuracy of lactose determination. Different treatments of spectral data did not improve the calibrations for fat and protein. For the region from 700 to 1100 nm, where inexpensive on-line sensors could be used, the highest positive coefficients for fat were at 930, 968, 990, 1026, 1076, and 1092 nm; for lactose were at 734, 750, 786, 812, 908, 974, 982, and 1064 nm; and for total protein were at 776, 880, 902, 952, and 1034 nm.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Smoothing and Differentiation of Data by Simplified Least Squares Procedures.
Savitzky, A., & Golay, M. J. E. (1964) · Analytical Chemistry · doi:10.1021/ac60214a047 · Cited by 21,904
Cited by
Jewell, K. A., McCormick, C. A., Odt, C. L., Weimer, P. J., & Suen, G. (2015) · Applied and Environmental Microbiology · doi:10.1128/aem.00720-15 · Cited by 280
Near-infrared spectroscopic sensing system for on-line milk quality assessment in a milking robot
Kawasaki, M., Kawamura, S., Tsukahara, M., Morita, S., Komiya, M., & Natsuga, M. (2008) · Computers and Electronics in Agriculture · doi:10.1016/j.compag.2008.01.006 · Cited by 134
Metadata
- Authors
- Tsenkova, R., Atanassova, S., Toyoda, K., Ozaki, Y., Itoh, K., & Fearn, T.
- Venue
- Journal of Dairy Science
- Publisher
- American Dairy Science Association
- Published
- 1999-11
- Volume
- 82
- Issue
- 11
- Pages
- 2344-2351
- ISSN
- 0022-0302 (ISSN-L)
- OpenAlex
- W2019159268
- Cited by
- 212
- References
- 1
- FWCI
- 6.05
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Near-Infrared Spectroscopy for Dairy Management: Measurement of Unhomogenized Milk Composition. https://app.cochat.ai/papers/10.3168/jds.s0022-0302(99)75484-6
- The paper
- Tsenkova, R., Atanassova, S., Toyoda, K., Ozaki, Y., Itoh, K., & Fearn, T. (1999). Near-Infrared Spectroscopy for Dairy Management: Measurement of Unhomogenized Milk Composition. Journal of Dairy Science. https://doi.org/10.3168/jds.s0022-0302(99)75484-6
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.