The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Augmented reality–guided neurosurgery: accuracy and intraoperative application of an image projection technique
Abstract
OBJECT: An augmented reality system has been developed for image-guided neurosurgery to project images with regions of interest onto the patient's head, skull, or brain surface in real time. The aim of this study was to evaluate system accuracy and to perform the first intraoperative application. METHODS: Images of segmented brain tumors in different localizations and sizes were created in 10 cases and were projected to a head phantom using a video projector. Registration was performed using 5 fiducial markers. After each registration, the distance of the 5 fiducial markers from the visualized tumor borders was measured on the virtual image and on the phantom. The difference was considered a projection error. Moreover, the image projection technique was intraoperatively applied in 5 patients and was compared with a standard navigation system. RESULTS: Augmented reality visualization of the tumors succeeded in all cases. The mean time for registration was 3.8 minutes (range 2–7 minutes). The mean projection error was 0.8 ± 0.25 mm. There were no significant differences in accuracy according to the localization and size of the tumor. Clinical feasibility and reliability of the augmented reality system could be proved intraoperatively in 5 patients (projection error 1.2 ± 0.54 mm). CONCLUSIONS: The augmented reality system is accurate and reliable for the intraoperative projection of images to the head, skull, and brain surface. The ergonomic advantage of this technique improves the planning of neurosurgical procedures and enables the surgeon to use direct visualization for image-guided neurosurgery.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Azuma, R. T. (1997) · Presence: Teleoperators and Virtual Environments · doi:10.1162/pres.1997.6.4.355 · Cited by 10,121
Cited by
Recent Development of Augmented Reality in Surgery: A Review
Vávra, P., Roman, J., Zonča, P., Ihnát, P., Němec, M., Kumar, J., Habib, N., & El-Gendi, A. (2017) · Journal of Healthcare Engineering · doi:10.1155/2017/4574172 · Cited by 394
Augmented reality in neurosurgery: a systematic review
Meola, A., Cutolo, F., Carbone, M., Cagnazzo, F., Ferrari, M., & Ferrari, V. (2017) · Neurosurgical Review · doi:10.1007/s10143-016-0732-9 · Cited by 349
Virtual Reality and Simulation in Neurosurgical Training
Bernardo, A. (2017) · World Neurosurgery · doi:10.1016/j.wneu.2017.06.140 · Cited by 314
Utilizing virtual and augmented reality for educational and clinical enhancements in neurosurgery
Pelargos, P. E., Nagasawa, D. T., Lagman, C., Tenn, S., Demos, J. V., Lee, S. J., Bui, T. T., Barnette, N. E., Bhatt, N. S., Ung, N., et al. (2017) · Journal of Clinical Neuroscience · doi:10.1016/j.jocn.2016.09.002 · Cited by 298
Metadata
- Authors
- Besharati Tabrizi, L., & Mahvash, M.
- Venue
- Journal of Neurosurgery
- Published
- 2015-07
- Volume
- 123
- Issue
- 1
- Pages
- 206-211
- ISSN
- 0022-3085 (ISSN-L)
- 1933-0693
- OpenAlex
- W2063855692
- Cited by
- 230
- References
- 1
- FWCI
- 13.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Augmented reality–guided neurosurgery: accuracy and intraoperative application of an image projection technique. https://app.cochat.ai/papers/10.3171/2014.9.jns141001
- The paper
- Besharati Tabrizi, L., & Mahvash, M. (2015). Augmented reality–guided neurosurgery: accuracy and intraoperative application of an image projection technique. Journal of Neurosurgery. https://doi.org/10.3171/2014.9.jns141001
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.