Red-light excitation of protoporphyrin IX fluorescence for subsurface tumor detection
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: The objective of this study was to detect 5-aminolevulinic acid (ALA)-induced tumor fluorescence from glioma below the surface of the surgical field by using red-light illumination. METHODS: To overcome the shallow tissue penetration of blue light, which maximally excites the ALA-induced fluorophore protoporphyrin IX (PpIX) but is also strongly absorbed by hemoglobin and oxyhemoglobin, a system was developed to illuminate the surgical field with red light (620–640 nm) matching a secondary, smaller absorption peak of PpIX and detecting the fluorescence emission through a 650-nm longpass filter. This wide-field spectroscopic imaging system was used in conjunction with conventional blue-light fluorescence for comparison in 29 patients undergoing craniotomy for resection of high-grade glioma, low-grade glioma, meningioma, or metastasis. RESULTS: Although, as expected, red-light excitation is less sensitive to PpIX in exposed tumor, it did reveal tumor at a depth up to 5 mm below the resection bed in 22 of 24 patients who also exhibited PpIX fluorescence under blue-light excitation during the course of surgery. CONCLUSIONS: Red-light excitation of tumor-associated PpIX fluorescence below the surface of the surgical field can be achieved intraoperatively and enables detection of subsurface tumor that is not visualized under conventional blue-light excitation. Clinical trial registration no.: NCT02191488 (clinicaltrials.gov)
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Stummer, W., Pichlmeier, U., Meinel, T., Wiestler, O. D., Zanella, F., & Reulen, H.-J. (2006) · The Lancet Oncology · doi:10.1016/s1470-2045(06)70665-9 · Cited by 3,423
Cited by
5‐ALA in the management of malignant glioma
Stepp, H., & Stummer, W. (2018) · Lasers in Surgery and Medicine · doi:10.1002/lsm.22933 · Cited by 234
Visualization technologies for 5-ALA-based fluorescence-guided surgeries
Wei, L., Roberts, D. W., Sanai, N., & Liu, J. T. C. (2019) · Journal of Neuro-Oncology · doi:10.1007/s11060-018-03077-9 · Cited by 67
Self-citationBravo, J. J., Olson, J. D., Davis, S. C., Roberts, D. W., Paulsen, K. D., & Kanick, S. C. (2017) · Scientific Reports · doi:10.1038/s41598-017-09727-8 · Cited by 53
Self-citationWirth, D. J., Sibai, M., Wilson, B. C., Roberts, D. W., & Paulsen, K. (2020) · Biomedical Optics Express · doi:10.1364/boe.397507 · Cited by 14
Self-citation
Metadata
- Authors
- Roberts, D. W., Olson, J. D., Evans, L. T., Kolste, K. K., Kanick, S. C., Fan, X., Bravo, J. J., Wilson, B. C., Leblond, F., Marois, M., & Paulsen, K. D.
- Venue
- Journal of Neurosurgery
- Published
- 2018-06
- Volume
- 128
- Issue
- 6
- Pages
- 1690-1697
- ISSN
- 0022-3085 (ISSN-L)
- 1933-0693
- OpenAlex
- W2742265809
- Cited by
- 61
- References
- 1
- FWCI
- 5.47
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.