Real-time imaging of convection-enhanced delivery of viruses and virus-sized particles
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Object: Despite recent evidence showing that convection-enhanced delivery (CED) of viruses and virus-sized particles to the central nervous system (CNS) is possible, little is known about the factors influencing distribution of these vectors with convection. To better define the delivery of viruses and virus-sized particles in the CNS, and to determine optimal parameters for infusion, the authors coinfused adeno-associated virus ([AAV], 24-nm diameter) and/or feru-moxtran-10 (24 nm) by using CED during real-time magnetic resonance (MR) imaging. Methods: Sixteen rats underwent intrastriatal convective coinfusion with 4 μl of 35 S-AAV capsids (0.5–1.0 × 10 14 viral particles/ml) and increasing concentrations (0.1, 0.5, 1, and 5 mg/ml) of a similar sized iron oxide MR imaging agent (ferumoxtran-10). Five nonhuman primates underwent either convective coinfusion of 35 S-AAV capsids and 1 mg/ml ferumoxtran-10 (striatum, one animal) or infusion of 1 mg/ml ferumoxtran-10 alone (striatum in two animals; frontal white matter in two). Clinical effects, MR imaging studies, quantitative autoradiography, and histological data were analyzed. Results: Real-time, T2-weighted MR imaging of ferumoxtran-10 during infusion revealed a clearly defined hypo-intense region of perfusion. Quantitative autoradiography confirmed that MR imaging of ferumoxtran-10 at a concentration of 1 mg/ml accurately tracked viral capsid distribution in the rat and primate brain (the mean difference in volume of distribution [Vd] was 7 and 15% in rats and primates, respectively). The Vd increased linearly with increasing volume of infusion (Vi) (R 2 = 0.98). The mean Vd/Vi ratio was 4.1 ± 0.2 (mean ± standard error of the mean) in gray and 2.3 ± 0.1 in white matter (p < 0.01). The distribution of infusate was homogeneous. Postinfusion MR imaging revealed leakback along the cannula track at infusion rates greater than 1.5 μl/minute in primate gray and white matter. No animal had clinical or histological evidence of toxicity. Conclusions: The CED method can be used to deliver AAV capsids and similar sized particles to the CNS safely and effectively over clinically relevant volumes. Moreover, real-time MR imaging of ferumoxtran-10 during infusion reveals that AAV capsids and similar sized particles have different convective delivery properties than smaller proteins and other compounds.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Noninvasive detection of clinically occult lymph-node metastases in prostate cancer
Harisinghani, M. G., Barentsz, J., Hahn, P. F., Deserno, W. M., Tabatabaei, S., van de Kaa, C. H., de la Rosette, J., & Weissleder, R. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa022749 · Cited by 1,971
Wang, Y.-X. J., Hussain, S. M., & Krestin, G. P. (2001) · European Radiology · doi:10.1007/s003300100908 · Cited by 1,381
Janson, C., McPhee, S., Bilaniuk, L., Haselgrove, J., Testaiuti, M., Freese, A., Wang, D.-J., Shera, D., Hurh, P., Rupin, J., et al. (2002) · Human Gene Therapy · doi:10.1089/104303402760128612 · Cited by 255
Cited by
Evolving Drug Delivery Strategies to Overcome the Blood Brain Barrier
S. Hersh, D., S. Wadajkar, A., B. Roberts, N., G. Perez, J., P. Connolly, N., Frenkel, V., A. Winkles, J., F. Woodworth, G., & J. Kim, A. (2016) · Current Pharmaceutical Design · doi:10.2174/1381612822666151221150733 · Cited by 387
“These range from small molecule chemotherapeutic agents [222-224] and imaging tracers [225-227] to larger compounds such as proteins [228], viruses [229, 230], and nanoparticles [231-236] (see Fig.”
Wakimoto, H., Kesari, S., Farrell, C. J., Curry, W. T., Zaupa, C., Aghi, M., Kuroda, T., Stemmer-Rachamimov, A., Shah, K., Liu, T.-C., et al. (2009) · Cancer Research · doi:10.1158/0008-5472.can-08-3886 · Cited by 361
Mehta, A. M., Sonabend, A. M., & Bruce, J. N. (2017) · Neurotherapeutics · doi:10.1007/s13311-017-0520-4 · Cited by 331
Kobayashi, H., Longmire, M. R., Ogawa, M., & Choyke, P. L. (2011) · Chemical Society Reviews · doi:10.1039/c1cs15077d · Cited by 216
Kateb, B., Chiu, K., Black, K. L., Yamamoto, V., Khalsa, B., Ljubimova, J. Y., Ding, H., Patil, R., Portilla-Arias, J. A., Modo, M., et al. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.01.105 · Cited by 188
“…moieties, distribution of nanoparticles within an organ can be tracked on real-time imaging studies, providing feedback that directs adjustments in infusion rate and volume,which should improvematching of the distribution to the nanoparticles to the distribution of the tumor (Szerlip et al., 2007).”
BackgroundConvection-enhanced drug delivery for glioblastoma: a review
D’Amico, R. S., Aghi, M. K., Vogelbaum, M. A., & Bruce, J. N. (2021) · Journal of Neuro-Oncology · doi:10.1007/s11060-020-03408-9 · Cited by 168
Parkinson's Disease Gene Therapy: Success by Design Meets Failure by Efficacy
Bartus, R. T., Weinberg, M. S., & Samulski, R. J. (2014) · Molecular Therapy · doi:10.1038/mt.2013.281 · Cited by 164
Su, X., Kells, A. P., Salegio, E. A., Richardson, R. M., Hadaczek, P., Beyer, J., Bringas, J., Pivirotto, P., Forsayeth, J., & Bankiewicz, K. S. (2010) · Molecular Therapy · doi:10.1038/mt.2010.114 · Cited by 82
Highly PEGylated DNA Nanoparticles Provide Uniform and Widespread Gene Transfer in the Brain
Mastorakos, P., Zhang, C., Berry, S., Oh, Y., Lee, S., Eberhart, C. G., Woodworth, G. F., Suk, J. S., & Hanes, J. (2015) · Advanced Healthcare Materials · doi:10.1002/adhm.201400800 · Cited by 80
T2 imaging in monitoring of intraparenchymal real-time convection-enhanced delivery
Richardson, R. M., Gimenez, F., Salegio, E. A., Su, X., Bringas, J., Berger, M. S., & Bankiewicz, K. S. (2011) · Neurosurgery · doi:10.1227/neu.0b013e318217217e · Cited by 38
“These difficulties may also explain the discrepancies reported by others between the MRI-visualized Vd and that calculated by quantitative autoradiography of a radiolabeled MRI tracer.(1,21) We also recently published data that suggest that gadoteridol distribution predicts the distribution of co-infused glial-derived…”
BackgroundResult
Metadata
- Authors
- Szerlip, N. J., Walbridge, S., Yang, L., Morrison, P. F., Degen, J. W., Jarrell, S. T., Kouri, J., Kerr, P. B., Kotin, R., Oldfield, E. H., & Lonser, R. R.
- Venue
- Journal of Neurosurgery
- Published
- 2007-09
- Volume
- 107
- Issue
- 3
- Pages
- 560-567
- ISSN
- 0022-3085 (ISSN-L)
- OpenAlex
- W2027775485
- Cited by
- 107
- References
- 3
- FWCI
- 3.68
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.