A simple gravimetric technique for measurement of cerebral edema
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
✓ A simple method was developed for the laboratory preparation of gradient columns of specific gravity used in measurement of brain-tissue water. By this automated technique, virtually linear and repeatable density gradients were obtained from which values of tissue specific gravity could be determined. The specific gravity of both solid and fresh cortex and white matter from adult cats was measured and converted to units of percent water per gram tissue using conversion factors derived for this purpose and applicable to studies of brain edema.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Handbook of Chemistry and Physics,
Di Cyan, E. (1970) · Archives of Internal Medicine · doi:10.1001/archinte.1970.00310080141025 · Cited by 1,730
THE DETERMINATION OF SERUM PROTEIN CONCENTRATION WITH A GRADIENT TUBE
Lowry, O. H., & Hunter, T. H. (1945) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(19)52808-3 · Cited by 149
Cerebral Circulation and Metabolism
(1975) · Springer eBooks · doi:10.1007/978-3-642-65814-3 · Cited by 94
DiMattio, J., Hochwald, G. M., Malhan, C., & Wald, A. (1975) · Pflügers Archiv - European Journal of Physiology · doi:10.1007/bf00587383 · Cited by 63
Cited by
Aquaporin-4 deletion in mice reduces brain edema after acute water intoxication and ischemic stroke
Manley, G. T., Fujimura, M., Ma, T., Noshita, N., Filiz, F., Bollen, A. W., Chan, P., & Verkman, A. S. (2000) · Nature Medicine · doi:10.1038/72256 · Cited by 1,507
Barzó, P., Marmarou, A., Fatouros, P., Hayasaki, K., & Corwin, F. (1997) · Journal of Neurosurgery · doi:10.3171/jns.1997.87.6.0900 · Cited by 371
Self-citationAggravation of vasogenic cerebral edema by multiple-dose mannitol
Kaufmann, A. M., & Cardoso, E. R. (1992) · Journal of Neurosurgery · doi:10.3171/jns.1992.77.4.0584 · Cited by 343
Pathogenesis of Brain Edema and Investigation into Anti-Edema Drugs
Michinaga, S., & Koyama, Y. (2015) · International Journal of Molecular Sciences · doi:10.3390/ijms16059949 · Cited by 339
“percentage of water is determined [2,90].”
MethodBaşkaya, M. K., Muralikrishna Rao, A., Doğan, A., Donaldson, D., & Dempsey, R. J. (1997) · Neuroscience Letters · doi:10.1016/s0304-3940(97)00239-5 · Cited by 332
“The specific gravity of samples taken from brains at the study sites was measured as an indicator of edema formation [3,4,13].”
Background
Metadata
- Authors
- Marmarou, A., Poll, W., Shulman, K., & Bhagavan, H.
- Venue
- Journal of Neurosurgery
- Published
- 1978-10
- Volume
- 49
- Issue
- 4
- Pages
- 530-537
- ISSN
- 0022-3085 (ISSN-L)
- OpenAlex
- W2116188145
- Cited by
- 266
- References
- 4
- FWCI
- 0.65
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.