The DOI matches its Crossref record.
A computerized tomography-computer graphics approach to stereotaxic localization
Abstract
✓ This paper describes the use of three-dimensional computer graphics to display structures visible in computerized tomography (CT) scans and to accurately determine optimum stereotaxic probe placement relative to those structures. A prototype Lucite stereotaxic frame designed for use in CT body scanners was fitted with a phantom consisting of small Lucite spheres representing intracranial tumors with diameters of 6 to 19 mm. A series of CT scans was obtained of the frame and phantom together. Edge outlines of the spheres were extracted from each scan in the series. A three-dimensional visual representation of the spheres was obtained by displaying their outlines from all CT scans. A superimposed visual simulation of the stereotaxic frame was adjusted interactively using several analog dials in order to simulate trajectory choice and probe depth before actual surgery. The frame settings and probe depth calculated by the graphical computer were then applied to the actual prototype frame in order to assess the accuracy of this combined CT-computer graphics approach to stereotaxic localization. The results of 22 such experiments and the implications for future clinical use of this new and precise localization technique are discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Medical image matching-a review with classification
van den Elsen, P. A., Pol, E.-J. D., & Viergever, M. A. (1993) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.195938 · Cited by 718
The Application Accuracy of Stereotactic Frames
Maciunas, R. J., Galloway, R. L., & Latimer, J. W. (1994) · Neurosurgery · doi:10.1227/00006123-199410000-00015 · Cited by 395
Craniotomy for Tumor Treatment in an Intraoperative Magnetic Resonance Imaging Unit
Black, P. M., Alexander, E., Martin, C., Moriarty, T., Nabavi, A., Wong, T. Z., Schwartz, R. B., & Jolesz, F. (1999) · Neurosurgery · doi:10.1097/00006123-199909000-00001 · Cited by 301
Computer-assisted Orthopedic Surgery
Sugano, N. (2003) · Journal of Orthopaedic Science · doi:10.1007/s10776-002-0623-6 · Cited by 184
Goldman, M. S., & Kelly, P. J. (1992) · Journal of Neurosurgery · doi:10.3171/jns.1992.77.2.0223 · Cited by 79
Metadata
- Authors
- Brown, R. A.
- Venue
- Journal of Neurosurgery
- Published
- 1979-06
- Volume
- 50
- Issue
- 6
- Pages
- 715-720
- ISSN
- 0022-3085 (ISSN-L)
- OpenAlex
- W2014176763
- Cited by
- 205
- References
- 0
- FWCI
- 8.52
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A computerized tomography-computer graphics approach to stereotaxic localization. https://app.cochat.ai/papers/10.3171/jns.1979.50.6.0715
- The paper
- Brown, R. A. (1979). A computerized tomography-computer graphics approach to stereotaxic localization. Journal of Neurosurgery. https://doi.org/10.3171/jns.1979.50.6.0715
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.