Operative management of selected brachial plexus lesions
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
✓ A 12-year operative experience with 171 consecutive patients with severe brachial plexus lesions who had at least 1½ years of follow-up review is analyzed. Selection for and timing of operation was helped by categorization of each individual plexus element as “completely” or “incompletely” injured and as “in continuity” or “not in continuity.” Results for each element could be given a single grade by a system which defined that element's proximal and distal input. For most lesions in continuity, an operative delay of several months is advocated so that intraoperative electrical evaluation can be used. Thus, in 282 gunshot wounded and stretch-injured elements of which 210 were thought to be clinically complete, 63 were spared resection because of nerve action potentials (NAP's) found at intraoperative testing, and 57 recovered function with only neurolysis. Elements resected (120) were confirmed as neurotmetic both by intraoperative electrical and subsequent histological studies. Acceptable results were achieved in 16 of 24 sutures, in 43 of 89 grafts, and in each of seven split repairs. Upper trunk and lateral and posterior cord elements fared better than lower trunk and medial cord lesions unless the latter were shown, with evidence of NAP's, to be regenerating and could be spared resection. Some stretched elements could, however, not be repaired, even though an attempt was made to exclude such cases from operation. Lacerations to the brachial plexus where continuity is lost are best repaired primarily if the injury is sharp; in this series, 14 of 18 elements having such repair recovered, whereas in 37 elements with secondary repair, grafts were often necessary and only 50% recovered function. Although associated with skin lacerations, 17 elements with complete loss were in continuity, and six of these were shown to be regenerating and were not resected. Despite intraneural location, large size, and prior operation, many benign tumors (including neurofibromas) can be removed without significant loss by use of the surgical loupes or microscope and repetitive NAP recording. Surgery for selected brachial plexus lesions is worthwhile.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Surgical Disorders of the Peripheral Nerves
(1972) · Medical Journal of Australia · doi:10.5694/j.1326-5377.1972.tb88216.x · Cited by 749
Management of Peripheral Nerve Problems
Thomas, P. (1981) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.44.8.749-a · Cited by 159
Electrophysiological recordings in peripheral nerve surgery: A review
Terzis, J. K., Dykes, R. W., & Hakstian, R. W. (1976) · The Journal Of Hand Surgery · doi:10.1016/s0363-5023(76)80025-1 · Cited by 63
Griffin, J. E. (1963) · Physical Therapy · doi:10.1093/ptj/43.3.230c · Cited by 50
Cited by
Kim, D. H., Cho, Y.-J., Tiel, R. L., & Kline, D. G. (2003) · Journal of Neurosurgery · doi:10.3171/jns.2003.98.5.1005 · Cited by 251
Self-citationKlinge, P. M., Vafa, M. A., Brinker, T., Brandis, A., Walter, G. F., Stieglitz, T., Samii, M., & Wewetzer, K. (2001) · Biomaterials · doi:10.1016/s0142-9612(00)00420-8 · Cited by 64
Metadata
- Authors
- Kline, D. G., & Judice, D. J.
- Venue
- Journal of Neurosurgery
- Published
- 1983-05
- Volume
- 58
- Issue
- 5
- Pages
- 631-649
- ISSN
- 0022-3085 (ISSN-L)
- OpenAlex
- W2102740369
- Cited by
- 166
- References
- 4
- FWCI
- 6.05
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.