Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 247

The DOI matches its Crossref record.

Application of frameless stereotaxy to pedicle screw fixation of the spine

Kalfas, Iain H., Kormos, Donald W., Murphy, Michael A., McKenzie, Rick L., Barnett, Gene H., Bell, Gordon R., Steiner, Charles P., Trimble, Mary Beth, Weisenberger, Joseph P.·1995·Journal of Neurosurgery

Abstract

✓ Interactive frameless stereotaxy has been successfully applied to intracranial surgery. It has contributed to the improved localization of deep-seated brain lesions and has demonstrated a potential for reducing both operative time and morbidity. However, it has not been as effectively applied to spinal surgery. The authors describe the application of frameless stereotactic techniques to spinal surgery, specifically pedicle screw fixation of the lumbosacral spine. Preoperative axial computerized tomography (CT) images of the appropriate spinal segments are obtained and loaded onto a high-speed graphics supercomputer workstation. Intraoperatively, these images can be linked to the appropriate spinal anatomy by a sonic localization digitizer device that is interfaced with the computer workstation. This permits the surgeon to place a pointing device (sonic wand) on any exposed spinal bone landmark in the operative field and obtain multiplanar reconstructed CT images projected in near-real time on the workstation screen. The images can be manipulated to assist the surgeon in determining the proper entry point for a pedicle screw as well as defining the appropriate trajectory in the axial and sagittal planes. It can also define the correct screw length and diameter for each pedicle to be instrumented. The authors applied this device to the insertion of 150 screws into the lumbosacral spines of 30 patients. One hundred forty-nine screws were assessed to be satisfactorily placed by postoperative CT and plain film radiography. In this report the authors discuss their use of this device in the clinical setting and review their preliminary results of frameless stereotaxy applied to spinal surgery. On the basis of their findings, the authors conclude that frameless stereotactic technology can be successfully applied to spinal surgery.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3171/jns.1995.83.4.0641

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 247

Metadata

Authors
Kalfas, I. H., Kormos, D. W., Murphy, M. A., McKenzie, R. L., Barnett, G. H., Bell, G. R., Steiner, C. P., Trimble, M. B., & Weisenberger, J. P.
Venue
Journal of Neurosurgery
Published
1995-10
Volume
83
Issue
4
Pages
641-647
ISSN
0022-3085 (ISSN-L)
OpenAlex
W2113413823
Cited by
247
References
0
FWCI
7.50
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Application of frameless stereotaxy to pedicle screw fixation of the spine. https://app.cochat.ai/papers/10.3171/jns.1995.83.4.0641
The paper
Kalfas, I. H., Kormos, D. W., Murphy, M. A., McKenzie, R. L., Barnett, G. H., Bell, G. R., Steiner, C. P., Trimble, M. B., & Weisenberger, J. P. (1995). Application of frameless stereotaxy to pedicle screw fixation of the spine. Journal of Neurosurgery. https://doi.org/10.3171/jns.1995.83.4.0641

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.