The DOI matches its Crossref record.
Guglielmi detachable coil embolization of acute intracranial aneurysm: perioperative anatomical and clinical outcome in 403 patients
Abstract
✓ From December 1990 to July 1995, the investigators participated in a prospective clinical study to evaluate the safety of the Guglielmi detachable coil (GDC) system for the treatment of aneurysms. This report summarizes the perioperative results from eight initial interventional neuroradiology centers in the United States. The report focuses on 403 patients who presented with acute subarachnoid hemorrhage from a ruptured intracranial aneurysm. These patients were treated within 15 days of the primary intracranial hemorrhage and were followed until they were discharged from the hospital or died. Seventy percent of the patients were female and 30% were male. The patients' mean age was 58 years old. Aneurysm size was categorized as small (60.8%), large (34.7%), and giant (4.5%); and neck size was categorized as small (53.6%), wide (36.2%), fusiform (6%), and undetermined (4.2%). Fifty-seven percent of the aneurysms were located in the posterior circulation and 43% in the anterior circulation. Eighty-two patients were classified as Hunt and Hess Grade I (20.3%), 105 Grade II (26.1%), 121 Grade III (30%), 69 Grade IV (17.1%), and 26 Grade V (6.5%). All patients in this study were excluded from surgical treatment either because of anticipated surgical difficulty (69.2%), attempted and failed surgery (12.7%), the patient's poor neurological (12.2%) or medical (4.7%) status, and/or refusal of surgery (1.2%). The GDC embolization was performed within 48 hours of primary hemorrhage in 147 patients (36.5%), within 3 to 6 days in 156 patients (38.7%), 7 to 10 days in 71 patients (17.6%), and 11 to 15 days in 29 patients (7.2%). Complete aneurysm occlusion was observed in 70.8% of small aneurysms with a small neck, 35% of large aneurysms, and 50% of giant aneurysms. A small neck remnant was observed in 21.4% of small aneurysms with a small neck, 57.1% of large aneurysms, and 50% of giant aneurysms. Technical complications included aneurysm perforation (2.7%), unintentional parent artery occlusion (3%), and untoward cerebral embolization (2.48%). There was a 8.9% immediate morbidity rate related to the GDC technique. Seven deaths were related to technical complications (1.74%) and 18 (4.47%) to the severity of the primary hemorrhage. The findings of this study demonstrate the safety of the GDC system for the treatment of ruptured intracranial aneurysms in anterior and posterior circulations. The authors believe additional randomized studies will further identify the role of this technique in the management of acutely ruptured incranial aneurysms.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Byrne, J. V., Sohn, M.-J., & Molyneux, A. J. (1999) · Journal of Neurosurgery · doi:10.3171/jns.1999.90.4.0656 · Cited by 485
Qureshi, A. I., Luft, A. R., Sharma, M., Guterman, L. R., & Hopkins, L. N. (2000) · Neurosurgery · doi:10.1097/00006123-200006000-00014 · Cited by 253
Endovascular Management of Intracranial Aneurysms: Current Experience and Future Advances
Koebbe, C. J., Veznedaroglu, E., Jabbour, P., & Rosenwasser, R. H. (2006) · Neurosurgery · doi:10.1227/01.neu.0000237512.10529.58 · Cited by 103
Vascular Dynamics of a Shape Memory Polymer Foam Aneurysm Treatment Technique
Ortega, J., Maitland, D., Wilson, T., Tsai, W., Savaş, Ö., & Saloner, D. (2007) · Annals of Biomedical Engineering · doi:10.1007/s10439-007-9358-y · Cited by 57
Metadata
- Authors
- Viñuela, F., Duckwiler, G., & Mawad, M.
- Venue
- Journal of Neurosurgery
- Published
- 1997-03
- Volume
- 86
- Issue
- 3
- Pages
- 475-482
- ISSN
- 0022-3085 (ISSN-L)
- OpenAlex
- W1980619534
- Cited by
- 875
- References
- 0
- FWCI
- 52.70
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Guglielmi detachable coil embolization of acute intracranial aneurysm: perioperative anatomical and clinical outcome in 403 patients. https://app.cochat.ai/papers/10.3171/jns.1997.86.3.0475
- The paper
- Viñuela, F., Duckwiler, G., & Mawad, M. (1997). Guglielmi detachable coil embolization of acute intracranial aneurysm: perioperative anatomical and clinical outcome in 403 patients. Journal of Neurosurgery. https://doi.org/10.3171/jns.1997.86.3.0475
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.