Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 253

The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.

Prevention and Treatment of Thromboembolic and Ischemic Complications Associated with Endovascular Procedures: Part II???Clinical Aspects and Recommendations

Qureshi, Adnan I., Luft, Andreas R., Sharma, Mudit, Guterman, Lee R., Hopkins, L. Nelson·2000·Neurosurgery

Abstract

We reviewed the incidence, risk factors, and clinical features of thromboembolic and ischemic events associated with diagnostic cerebral angiography, endovascular treatment of aneurysms using coils or balloons, angioplasty and stent placement to treat extracranial carotid artery stenosis, and embolization of arteriovenous malformations using glue or other embolic agents. We performed a cumulative analysis to determine the frequency and characteristics of these events and a subset analysis (whenever possible) to determine the benefits of various strategies for complication avoidance. Of the 1,547 patients who underwent Guglielmi detachable coil treatment, thromboembolic events were observed for 127 (8.2%), consisting of asymptomatic events for 12 patients, transient ischemic attacks for 29, and strokes for 86. The outcomes for the 86 patients with strokes were categorized as full recovery for 15, good recovery for 27, partial recovery for 19, no recovery for 11, death for 12, and undetermined outcome for 2. Of the 834 patients who underwent carotid angioplasty and stent placement, thromboembolic events were observed for 73 (8.8%), consisting of transient ischemic attacks for 26 patients and strokes for 47. The outcomes for the patients with strokes were categorized as full recovery for 20, good recovery for 15, partial recovery for 6, no recovery for 2, and death for 4. High rates of thromboembolic events were also observed with balloon occlusion of aneurysms (11%) or parent arteries (19%) and carotid angioplasty alone (5.9%). Arteriovenous malformation embolization was associated with an ischemic event/procedure rate of 9.4%. High rates of thromboembolic and ischemic complications, with subsequent morbidity and death, are associated with most endovascular procedures. Further research and the formulation of standard preventive guidelines may help to reduce these risks and improve the overall success of these procedures.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00006123-200006000-00014

Cites

30 of 30 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 30 references

Cited by

See all 253

Metadata

Authors
Qureshi, A. I., Luft, A. R., Sharma, M., Guterman, L. R., & Hopkins, L. N.
Venue
Neurosurgery
Published
2000-06
Volume
46
Issue
6
Pages
1360-1376
ISSN
0148-396X (ISSN-L)
OpenAlex
W1970079178
Cited by
253
References
30
FWCI
10.02
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Prevention and Treatment of Thromboembolic and Ischemic Complications Associated with Endovascular Procedures: Part II???Clinical Aspects and Recommendations. https://app.cochat.ai/papers/10.1097/00006123-200006000-00014
The paper
Qureshi, A. I., Luft, A. R., Sharma, M., Guterman, L. R., & Hopkins, L. N. (2000). Prevention and Treatment of Thromboembolic and Ischemic Complications Associated with Endovascular Procedures: Part II???Clinical Aspects and Recommendations. Neurosurgery. https://doi.org/10.1097/00006123-200006000-00014

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.