The DOI matches its Crossref record.
Validation of the optic nerve sheath response to changing cerebrospinal fluid pressure: ultrasound findings during intrathecal infusion tests
Abstract
✓ Raised intracranial pressure leads to increased pressure around the optic nerve (ON), which underlies the formation of papilledema and the enlargement of the dural optic nerve sheath (ONS). In clinical practice, the presence of widened ONSs is demonstrable on neuroimaging, but their relationship to cerebrospinal fluid (CSF) pressure remains unknown. The authors investigated the ONS response to pressure during CSF absorption studies in 12 patients undergoing neurological testing. The ONS diameter was evaluated by serial B-mode ultrasound scans of the anterior ON near its entry into the globe. All patients tested showed ONS diameter changes that exhibited covariance with the alteration of lumbar CSF pressure and were completely reversible during the infusion tests. The maximum difference in ONS diameter between baseline and peak pressure conditions was 1.8 mm on average (range 0.7–3.1 mm), corresponding to an average ONS diameter variation of 45% (range 15–89%). Regression analysis yielded a linear covariance between ONS diameter and CSF pressure with different slopes across subjects (0.019–0.071 mm/mm Hg, mean r = 0.78). However, this linear relationship was only present within a CSF pressure interval. This interval differed between patients: ONS dilation commenced at pressure thresholds between 15 mm Hg and 30 mm Hg and in some patients saturation of the response (constant ONS diameter) occurred between 30 mm Hg and 40 mm Hg. With a single exception, definitely enlarged ONS diameters (> 5 mm) were present when CSF pressure exceeded levels of 30 mm Hg. Retrospectively, discrimination between normal and elevated outflow resistance was possible on the basis of the ONS response to intrathecal infusion alone. It is concluded that the human ONS has sufficient elasticity to allow a detectable dilation in response to intracranial hypertension. Because of a variable pressure—diameter relationship, the subarachnoid pressure cannot be predicted exactly by single scans. Therefore, the clinical relevance of this method relies on the demonstration of pathologically enlarged sheaths or ongoing enlargement on serial ultrasonography studies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Dubourg, J., Javouhey, E., Geeraerts, T., Messerer, M., & Kassai, B. (2011) · Intensive Care Medicine · doi:10.1007/s00134-011-2224-2 · Cited by 611
Correlation of Optic Nerve Sheath Diameter with Direct Measurement of Intracranial Pressure
Kimberly, H. H., Shah, S., Marill, K., & Noble, V. (2008) · Academic Emergency Medicine · doi:10.1111/j.1553-2712.2007.00031.x · Cited by 541
Geeraerts, T., Merceron, S., Benhamou, D., Vigué, B., & Duranteau, J. (2008) · Intensive Care Medicine · doi:10.1007/s00134-008-1149-x · Cited by 425
Geeraerts, T., Newcombe, V. F., Coles, J. P., Abate, M. G., Perkes, I. E., Hutchinson, P. J., Outtrim, J. G., Chatfield, D. A., & Menon, D. K. (2008) · Critical Care · doi:10.1186/cc7006 · Cited by 296
Large-Volume Intrathecal Administrations: Impact on CSF Pressure and Safety Implications
Belov, V., Appleton, J., Levin, S., Giffenig, P., Durcanova, B., & Papisov, M. (2021) · Frontiers in Neuroscience · doi:10.3389/fnins.2021.604197 · Cited by 36
Metadata
- Authors
- Hansen, H.-C., & Helmke, K.
- Venue
- Journal of Neurosurgery
- Published
- 1997-07
- Volume
- 87
- Issue
- 1
- Pages
- 34-40
- ISSN
- 0022-3085 (ISSN-L)
- OpenAlex
- W1976169343
- Cited by
- 466
- References
- 0
- FWCI
- 0.26
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Validation of the optic nerve sheath response to changing cerebrospinal fluid pressure: ultrasound findings during intrathecal infusion tests. https://app.cochat.ai/papers/10.3171/jns.1997.87.1.0034
- The paper
- Hansen, H.-C., & Helmke, K. (1997). Validation of the optic nerve sheath response to changing cerebrospinal fluid pressure: ultrasound findings during intrathecal infusion tests. Journal of Neurosurgery. https://doi.org/10.3171/jns.1997.87.1.0034
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.