Correlation of Optic Nerve Sheath Diameter with Direct Measurement of Intracranial Pressure
Open accessAbstract
Background: Measurements of the optic nerve sheath diameter (ONSD) using bedside ultrasound (US) have been shown to correlate with clinical and radiologic signs and symptoms of increased intracranial pressure (ICP). Objectives: Previous literature has identified 5 mm as the ONSD measurement above which patients exhibit either clinical or radiologic signs of elevated ICP. The goals of this study were to evaluate the association between ONSD and ICP and to validate the commonly used ONSD threshold of 5 mm using direct measurements of ICP as measured by ventriculostomy. Methods: A prospective blinded observational study was performed using a convenience sample of adult patients in both the emergency department (ED) and the neurologic intensive care unit (ICU) who had invasive intracranial monitors placed as part of their clinical care. Ocular USs were performed with a 10–5 MHz linear probe. Emergency physicians (EPs) with previous ocular US experience performed ONSD measurements while blinded to the contemporaneous ICP reading obtained directly from invasive monitoring. The association between ONSD and ICP was assessed with the Spearman rank correlation coefficient, and a receiver operator characteristic (ROC) curve was created to determine the optimal ONSD cutoff to detect ICP > 20 cm H 2 O. Results: Thirty‐eight ocular USs were performed on 15 individual patients. Spearman rank correlation coefficient of ONSD and ICP was 0.59 (p < 0.0005) demonstrating a significant positive correlation. An ROC curve was created to assess the ability of ONSD to distinguish an abnormal ICP greater than 20 cm H 2 O. The area under the ROC curve was 0.93 (95% confidence interval [CI] = 0.84 to 0.99). Based on inspection of the ROC curve, ONSD > 5 mm performed well to detect ICP > 20 cm H 2 O with a sensitivity of 88% (95% CI = 47% to 99%) and specificity of 93% (95% CI = 78% to 99%). Conclusions: Using an ROC curve the authors systematically confirmed the commonly used threshold of ONSD > 5 mm to detect ICP > 20 cm H 2 O. This study directly correlates ventriculostomy measurements of ICP with US ONSD measurements and provides further support for the use of ONSD measurements as a noninvasive test for elevated ICP.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Robba, C., Santori, G., Czosnyka, M., Corradi, F., Bragazzi, N., Padayachy, L., Taccone, F. S., & Citerio, G. (2018) · Intensive Care Medicine · doi:10.1007/s00134-018-5305-7 · Cited by 420
Intracranial Pressure Monitoring: Invasive versus Non-Invasive Methods—A Review
Raboel, P. H., Bartek, J., Andresen, M., Bellander, B. M., & Romner, B. (2012) · Critical Care Research and Practice · doi:10.1155/2012/950393 · Cited by 416
Prediction of poor neurological outcome in comatose survivors of cardiac arrest: a systematic review
Sandroni, C., D’Arrigo, S., Cacciola, S., Hoedemaekers, C. W. E., Kamps, M. J. A., Oddo, M., Taccone, F. S., Di Rocco, A., Meijer, F. J. A., Westhall, E., et al. (2020) · Intensive Care Medicine · doi:10.1007/s00134-020-06198-w · Cited by 359
Risdall, J. E., & Menon, D. K. (2011) · Philosophical Transactions of the Royal Society B: Biological Sciences · doi:10.1098/rstb.2010.0230 · Cited by 185
Metadata
- Authors
- Kimberly, H. H., Shah, S., Marill, K., & Noble, V.
- Venue
- Academic Emergency Medicine
- Publisher
- Wiley
- Published
- 2008-02
- Volume
- 15
- Issue
- 2
- Pages
- 201-204
- ISSN
- 1069-6563 (ISSN-L)
- 1553-2712
- OpenAlex
- W2080481026
- Cited by
- 541
- References
- 0
- FWCI
- 9.43
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Correlation of Optic Nerve Sheath Diameter with Direct Measurement of Intracranial Pressure. https://app.cochat.ai/papers/10.1111/j.1553-2712.2007.00031.x
- The paper
- Kimberly, H. H., Shah, S., Marill, K., & Noble, V. (2008). Correlation of Optic Nerve Sheath Diameter with Direct Measurement of Intracranial Pressure. Academic Emergency Medicine. https://doi.org/10.1111/j.1553-2712.2007.00031.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.