Correlation of Optic Nerve Sheath Diameter with Direct Measurement of Intracranial Pressure

Open access
Kimberly, Heidi Harbison, Shah, Sachita, Marill, Keith, Noble, Vicki·2008·Academic Emergency Medicine

Abstract

Background: Measurements of the optic nerve sheath diameter (ONSD) using bedside ultrasound (US) have been shown to correlate with clinical and radiologic signs and symptoms of increased intracranial pressure (ICP). Objectives: Previous literature has identified 5 mm as the ONSD measurement above which patients exhibit either clinical or radiologic signs of elevated ICP. The goals of this study were to evaluate the association between ONSD and ICP and to validate the commonly used ONSD threshold of 5 mm using direct measurements of ICP as measured by ventriculostomy. Methods: A prospective blinded observational study was performed using a convenience sample of adult patients in both the emergency department (ED) and the neurologic intensive care unit (ICU) who had invasive intracranial monitors placed as part of their clinical care. Ocular USs were performed with a 10–5 MHz linear probe. Emergency physicians (EPs) with previous ocular US experience performed ONSD measurements while blinded to the contemporaneous ICP reading obtained directly from invasive monitoring. The association between ONSD and ICP was assessed with the Spearman rank correlation coefficient, and a receiver operator characteristic (ROC) curve was created to determine the optimal ONSD cutoff to detect ICP > 20 cm H 2 O. Results: Thirty‐eight ocular USs were performed on 15 individual patients. Spearman rank correlation coefficient of ONSD and ICP was 0.59 (p < 0.0005) demonstrating a significant positive correlation. An ROC curve was created to assess the ability of ONSD to distinguish an abnormal ICP greater than 20 cm H 2 O. The area under the ROC curve was 0.93 (95% confidence interval [CI] = 0.84 to 0.99). Based on inspection of the ROC curve, ONSD > 5 mm performed well to detect ICP > 20 cm H 2 O with a sensitivity of 88% (95% CI = 47% to 99%) and specificity of 93% (95% CI = 78% to 99%). Conclusions: Using an ROC curve the authors systematically confirmed the commonly used threshold of ONSD > 5 mm to detect ICP > 20 cm H 2 O. This study directly correlates ventriculostomy measurements of ICP with US ONSD measurements and provides further support for the use of ONSD measurements as a noninvasive test for elevated ICP.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1553-2712.2007.00031.x

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 541

Metadata

Authors
Kimberly, H. H., Shah, S., Marill, K., & Noble, V.
Venue
Academic Emergency Medicine
Publisher
Wiley
Published
2008-02
Volume
15
Issue
2
Pages
201-204
ISSN
  • 1069-6563 (ISSN-L)
  • 1553-2712
OpenAlex
W2080481026
Cited by
541
References
0
FWCI
9.43
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Correlation of Optic Nerve Sheath Diameter with Direct Measurement of Intracranial Pressure. https://app.cochat.ai/papers/10.1111/j.1553-2712.2007.00031.x
The paper
Kimberly, H. H., Shah, S., Marill, K., & Noble, V. (2008). Correlation of Optic Nerve Sheath Diameter with Direct Measurement of Intracranial Pressure. Academic Emergency Medicine. https://doi.org/10.1111/j.1553-2712.2007.00031.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.