Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 185

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Use of magnetic resonance imaging for in vivo measurements of water content in human brain: method and normal values

Fatouros, Panos P., Marmarou, Anthony·1999·Journal of Neurosurgery

Abstract

Object. The authors present a quantitative in vivo magnetic resonance (MR) imaging method and propose its use for the accurate assessment of brain water in humans. Methods. With this technique, a pure T 1-weighted image of a selected brain slice in a patient is generated, and the image is subsequently converted to a pure water image by means of an equation derived from a tissue relaxation model. The image intensity in the resulting water map directly yields absolute measures of water expressed in grams of water per gram of tissue at a given anatomical location. The method has been validated previously in a series of phantom experiments and in an infusion model of brain edema in cats. In this report, the authors evaluate the method by using samples of tissue harvested from patients who underwent surgery for brain tumor removal and apply the technique to a series of normal volunteers, providing average regional brain water content (f w) values for a range of tissues. Application of the method in pathological conditions such as head trauma, tumor, and hydrocephalus allows quantification of regional or global increases in f w that result from edema. Conclusions. It is now possible to obtain accurate brain water measurements with the anatomical resolution of MR imaging. This permits monitoring of the development and resolution of edema in a variety of clinical circumstances, thus enhancing understanding of the underlying pathophysiological processes.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3171/jns.1999.90.1.0109

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 185

Metadata

Authors
Fatouros, P. P., & Marmarou, A.
Venue
Journal of Neurosurgery
Published
1999-01
Volume
90
Issue
1
Pages
109-115
ISSN
0022-3085 (ISSN-L)
OpenAlex
W2011840283
Cited by
185
References
1
FWCI
8.51
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Use of magnetic resonance imaging for in vivo measurements of water content in human brain: method and normal values. https://app.cochat.ai/papers/10.3171/jns.1999.90.1.0109
The paper
Fatouros, P. P., & Marmarou, A. (1999). Use of magnetic resonance imaging for in vivo measurements of water content in human brain: method and normal values. Journal of Neurosurgery. https://doi.org/10.3171/jns.1999.90.1.0109

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.