The DOI matches its Crossref record.
Embolization of incidental cerebral aneurysms by using the Guglielmi detachable coil system
Abstract
Object. Guglielmi detachable coil (GDC) technology is a valuable therapeutic alternative to the surgical treatment of ruptured or incidental intracranial aneurysms. The authors describe their technical and clinical experience in the use of the GDC technique in patients who underwent endovascular occlusion for the treatment of incidentally found intracranial aneurysms. Methods. One hundred fifteen patients with 120 incidentally found intracranial aneurysms underwent embolization by means of the GDC endovascular technique. Ninety-one patients were females and 24 were males. Patient age ranged from 13 to 80 years. In 64 patients the incidental aneurysms were discovered when unrelated nonneurological conditions signaled the need for angiography or magnetic resonance angiography (Group 1). Twenty patients who presented with incidental aneurysms that were discovered during treatment for an acutely ruptured aneurysm underwent treatment of both types of aneurysm during the acute phase of subarachnoid hemorrhage (SAH) (Group 2). Sixteen patients with incidental aneurysms were treated during the chronic phase of SAH (Group 3). Group 4 included 15 patients who had incidental aneurysms associated with brain tumors or arteriovenous malformations. Angiographic results revealed complete or near-complete occlusion in 109 aneurysms (91%) and incomplete occlusion in five aneurysms (4%). Guglielmi detachable coil embolization was attempted unsuccessfully in six aneurysms (5%). One hundred nine patients (94.8%) remained neurologically intact or unchanged from their initial clinical status. Five patients (4.3%) deteriorated as a result of immediate procedural complications. All these complications occurred in the first 50 patients treated in the series. No clinical complications were observed in the last 65 patients. In one patient, a partially embolized aneurysm ruptured 3 years postprocedure. In Groups 1 and 3, the average length of hospitalization was 3.3 days. Conclusions. The evolution of GDC technology has proved to provide safe treatment of incidental aneurysms (a morbidity rate of 0% was achieved in the last 65 patients). The topography of the aneurysm and the clinical condition of the patient did not influence final anatomical or clinical outcomes. The GDC technology also confers a positive economic impact by decreasing hospital length of stay and by eliminating the need for postembolization intensive care.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Raymond, J., Guilbert, F., Weill, A., Georganos, S. A., Juravsky, L., Lambert, A., Lamoureux, J., Chagnon, M., & Roy, D. (2003) · Stroke · doi:10.1161/01.str.0000073841.88563.e9 · Cited by 1,496
Thompson, B. G., Brown, R. D., Amin-Hanjani, S., Broderick, J. P., Cockroft, K. M., Connolly, E. S., Duckwiler, G. R., Harris, C. C., Howard, V. J., Johnston, S. C. (., et al. (2015) · Stroke · doi:10.1161/str.0000000000000070 · Cited by 1,046
Self-citationEndovascular Treatment of Unruptured Aneurysms
Roy, D., Milot, G., & Raymond, J. (2001) · Stroke · doi:10.1161/hs0901.095600 · Cited by 961
Campi, A., Ramzi, N., Molyneux, A. J., Summers, P. E., Kerr, R. S. C., Sneade, M., Yarnold, J. A., Rischmiller, J., & Byrne, J. V. (2007) · Stroke · doi:10.1161/strokeaha.106.466987 · Cited by 553
Ferns, S. P., Sprengers, M. E. S., van Rooij, W. J., Rinkel, G. J. E., van Rijn, J. C., Bipat, S., Sluzewski, M., & Majoie, C. B. L. M. (2009) · Stroke · doi:10.1161/strokeaha.109.553099 · Cited by 455
Metadata
- Authors
- Murayama, Y., Viñuela, F., Duckwiler, G. R., Gobin, Y. P., & Guglielmi, G.
- Venue
- Journal of Neurosurgery
- Published
- 1999-02
- Volume
- 90
- Issue
- 2
- Pages
- 207-214
- ISSN
- 0022-3085 (ISSN-L)
- OpenAlex
- W2133498839
- Cited by
- 227
- References
- 0
- FWCI
- 14.85
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Embolization of incidental cerebral aneurysms by using the Guglielmi detachable coil system. https://app.cochat.ai/papers/10.3171/jns.1999.90.2.0207
- The paper
- Murayama, Y., Viñuela, F., Duckwiler, G. R., Gobin, Y. P., & Guglielmi, G. (1999). Embolization of incidental cerebral aneurysms by using the Guglielmi detachable coil system. Journal of Neurosurgery. https://doi.org/10.3171/jns.1999.90.2.0207
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.