Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 334

The DOI matches its Crossref record.

Variables affecting convection-enhanced delivery to the striatum: a systematic examination of rate of infusion, cannula size, infusate concentration, and tissue—cannula sealing time

Chen, Michael Y., Lonser, Russell R., Morrison, Paul F., Governale, Lance S., Oldfield, Edward H.·1999·Journal of Neurosurgery

Abstract

Object. Although recent studies have shown that convection can be used to distribute macromolecules within the central nervous system (CNS) in a homogeneous, targeted fashion over clinically significant volumes and that the volume of infusion and target location (gray as opposed to white matter) influence distribution, little is known about other factors that may influence optimum use of convection-enhanced distribution. To understand the variables that affect convective delivery more fully, we examined the rate of infusion, delivery cannula size, concentration of infusate, and preinfusion sealing time. Methods. The authors used convection to deliver 4 µl of 14 C-albumin to the striatum of 40 rats. The effect of the rate of infusion (0.1, 0.5, 1, and 5 µl/minute), cannula size (32, 28, and 22 gauge), concentration of infusate (100%, 50%, and 25%), and preinfusion sealing time (0 and 70 minutes) on convective delivery was examined using quantitative autoradiography, National Institutes of Health image analysis software, scintillation analysis, and histological analysis. Higher rates of infusion (1 and 5 µl/minute) caused significantly (p < 0.05) more leakback of infusate (22.7 ± 11.7% and 30.3 ± 7.8% [mean ± standard deviation], respectively) compared with lower rates (0.1 µl/minute [4 ± 3.6%] and 0.5 µl/minute [5.2 µ 3.6%]). Recovery of infusate was significantly (p < 0.05) higher at the infusion rate of 0.1 µl/minute (95.1 ± 2.8%) compared with higher rates (85.2 ± 4%). The use of large cannulae (28 and 22 gauge) produced significantly (p < 0.05) more leakback (35.7 ± 8.1% and 21.1 ± 7.5%, respectively) than the smaller cannula (32 gauge [5.2 ± 3.6%]). Varying the concentration of the infusate and the preinfusion sealing time did not alter the volume of distribution, regional distribution, or infusate recovery. Conclusions. Rate of infusion and cannula size can significantly affect convective distribution of molecules, whereas preinfusion sealing time and variations in infusate concentration have no effect in this small animal model. Understanding the parameters that influence convective delivery within the CNS can be used to enhance delivery of potentially therapeutic agents in an experimental setting and to indicate the variables that will need to be considered for optimum use of this approach for drug delivery in the clinical setting.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3171/jns.1999.90.2.0315

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 334

Metadata

Authors
Chen, M. Y., Lonser, R. R., Morrison, P. F., Governale, L. S., & Oldfield, E. H.
Venue
Journal of Neurosurgery
Published
1999-02
Volume
90
Issue
2
Pages
315-320
ISSN
0022-3085 (ISSN-L)
OpenAlex
W2007719782
Cited by
334
References
0
FWCI
4.67
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Variables affecting convection-enhanced delivery to the striatum: a systematic examination of rate of infusion, cannula size, infusate concentration, and tissue—cannula sealing time. https://app.cochat.ai/papers/10.3171/jns.1999.90.2.0315
The paper
Chen, M. Y., Lonser, R. R., Morrison, P. F., Governale, L. S., & Oldfield, E. H. (1999). Variables affecting convection-enhanced delivery to the striatum: a systematic examination of rate of infusion, cannula size, infusate concentration, and tissue—cannula sealing time. Journal of Neurosurgery. https://doi.org/10.3171/jns.1999.90.2.0315

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.