The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
New laboratory model for neurosurgical training that simulates live surgery
Abstract
Object. Laboratory training models are essential for developing and refining surgical skills, especially for microsurgery. The closer to live surgery the model is, the greater the benefit. In this paper the authors introduce a cadaver model with unique characteristics: dynamic filling of the cerebral vasculature with colored liquid and clear fluid filling of the arachnoid cisterns. This model is distinctive and has great practical value for training in a wide range of surgical procedures. Methods. Cadaveric heads were prepared for surgical procedures in the following manner: the carotid arteries (CAs) and vertebral arteries (VAs) in the neck were cannulated, as were the internal jugular veins (JVs) on both sides. Two tubes were introduced into the spinal canal and each one was advanced into one of the cerebellopontine angle cisterns. A CA, VA, or both were then connected to a reservoir containing light red fluid and a pressure of 80 to 120 mm Hg and a pulse rate of 60 beats/minute were established using a pump. The JV on the side currently being dissected was connected to a reservoir containing dark red fluid and kept at a pressure between 20 and 40 mm Hg. The remaining vessels were clamped in the neck. The cisternal tubes were connected to a reservoir of clear fluid that was regulated by an adjustable flow. Nine trainees have tested this model on eight specimens by practicing a variety of surgical procedures and maneuvers, including craniotomies; hemostasis; cisternal and vascular dissection; vascular anastomosis and repair; establishment of arterial bypasses; aneurysm creation, dissection, and clipping; management of an aneurysm rupture; intraparenchymal resection such as amygdalohippocampectomy; ventricular endoscopy and third ventriculostomy; cavernous sinus and skull base approaches; and resection of artificial tumors in the basal cisterns. Conclusions. This model mimics the normal human anatomy and dynamic vascular filling found in real surgery and presents it from the training perspective, allowing a wide range of skill development and repeated practice. It provides an alternative model to laboratory animals. It is inexpensive and readily available, and has great value for the acquisition and refinement of surgical skills that are not only specific to neurosurgery, but are applicable to other surgical disciplines.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Microsurgical anatomy of the middle cerebral artery
Gibo, H., Carver, C. C., Rhoton, A. L., Lenkey, C., & Mitchell, R. J. (1981) · Journal of neurosurgery · doi:10.3171/jns.1981.54.2.0151 · Cited by 530
Cited by
Innovations in surgery simulation: a review of past, current and future techniques
Badash, I., Burtt, K., Solorzano, C. A., & Carey, J. N. (2016) · Annals of Translational Medicine · doi:10.21037/atm.2016.12.24 · Cited by 345
Metadata
- Authors
- Aboud, E., Al-Mefty, O., & Yaşargil, M. G.
- Venue
- Journal of Neurosurgery
- Published
- 2002-12
- Volume
- 97
- Issue
- 6
- Pages
- 1367-1372
- ISSN
- 0022-3085 (ISSN-L)
- OpenAlex
- W1992289884
- Cited by
- 229
- References
- 1
- FWCI
- 2.72
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.