Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 168

The DOI matches its Crossref record.

Safety and efficacy of a novel polyethylene glycol hydrogel sealant for watertight dural repair

Cosgrove, G. Rees, Delashaw, Johnny B., Grotenhuis, J. Andre, Tew, John M., van Loveren, Harry, Spetzler, Robert F., Payner, Troy, Rosseau, Gail, Shaffrey, Mark E., Hopkins, L. Nelson, Byrne, Richard, Norbash, Alex·2007·Journal of Neurosurgery

Abstract

Object: The authors prospectively evaluated the safety and efficacy of a novel polyethylene glycol (PEG) hydrogel sealant in patients undergoing elective cranial surgery with documented cerebrospinal fluid (CSF) leakage after sutured dural repair. Methods: The PEG hydrogel sealant was used at 11 different study sites in 111 patients with documented intraoperative CSF leakage after neurosurgical dural repair for a variety of conditions. Intraoperative CSF leakage was either spontaneous or induced by a Valsalva maneuver. Patients were monitored for 3 months postoperatively with physical examinations, clinical laboratory analyses, and diagnostic imaging. The PEG hydrogel sealant was 100% effective in stopping CSF leakage in all patients. There were no sealant-related adverse events and all clinical outcomes were consistent with expectations for seriously ill patients undergoing prolonged neurosurgical procedures. Conclusions: The PEG hydrogel sealant provides a safe and effective watertight closure when used as an adjunct to sutured dural repair during cranial surgery.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3171/jns.2007.106.1.52

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 168

Metadata

Authors
Cosgrove, G. R., Delashaw, J. B., Grotenhuis, J. A., Tew, J. M., van Loveren, H., Spetzler, R. F., Payner, T., Rosseau, G., Shaffrey, M. E., Hopkins, L. N., Byrne, R., & Norbash, A.
Venue
Journal of Neurosurgery
Published
2007-01
Volume
106
Issue
1
Pages
52-58
ISSN
0022-3085 (ISSN-L)
OpenAlex
W2170942934
Cited by
168
References
0
FWCI
5.32
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Safety and efficacy of a novel polyethylene glycol hydrogel sealant for watertight dural repair. https://app.cochat.ai/papers/10.3171/jns.2007.106.1.52
The paper
Cosgrove, G. R., Delashaw, J. B., Grotenhuis, J. A., Tew, J. M., van Loveren, H., Spetzler, R. F., Payner, T., Rosseau, G., Shaffrey, M. E., Hopkins, L. N., Byrne, R., & Norbash, A. (2007). Safety and efficacy of a novel polyethylene glycol hydrogel sealant for watertight dural repair. Journal of Neurosurgery. https://doi.org/10.3171/jns.2007.106.1.52

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.