Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 193

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

First Clinical Study on Ultra-High-Field MR Imaging in Patients with Multiple Sclerosis: Comparison of 1.5T and 7T

Open access
Kollia, K., Maderwald, S., Putzki, N., Schlamann, M., Theysohn, J.M., Kraff, O., Ladd, M.E., Forsting, M., Wanke, I. · 2009 · American Journal of Neuroradiology

Abstract

BACKGROUND AND PURPOSE: Higher magnetic field strengths and continuous improvement of high-resolution imaging in multiple sclerosis (MS) are expected to provide unique in-vivo and non-invasive insights in pathogenesis and clinical monitoring. The purpose of this study was to investigate the potential of high-resolution imaging of MS lesions in vivo comparing 7T with conventional 1.5T. MATERIALS AND METHODS: Twelve consecutive patients with clinically definite MS were scanned on a 7T whole-body scanner and on a 1.5T Avanto. The 1.5T and 7T imaging protocol consisted of high-resolution axial proton density (PD) + T2-weighted turbo spin-echo and T2*-weighted gradient-echo (GRE), and sagittal T1-weighted 3D magnetization-prepared rapid acquisition of gradient echo. RESULTS: The sequence parameters at 7T had to be modified because of specific absorption rate (SAR) restrictions while keeping contrast parameters equivalent to 1.5T. White matter lesions were better detected and delineated from adjacent structures at 7T compared with 1.5T. There were 42% of the patients who showed additional lesions at 7T: there were 97 white matter lesions detected on 1.5T versus 126 lesions at 7T, an increase of 23%. The perivascular migration of MS lesions was well visualized on T2*-weighted GRE sequences. In larger lesions (10 mm), a multilayer structure was revealed on T2*-weighted GRE not seen at 1.5T. Because of the higher resolution, it was possible to differentiate between juxtacortical white matter lesions and cortical lesions. There were 44% of the subcortical lesions depicted at 7T that showed cortical involvement. CONCLUSIONS: Ultra-high-field imaging of patients with MS at 7T was well tolerated and provided better visualization of MS lesions in the gray matter and demonstrated structural abnormalities within the MS lesions themselves more effectively.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3174/ajnr.a1434

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 193

Metadata

Authors
Kollia, K., Maderwald, S., Putzki, N., Schlamann, M., Theysohn, J. M., Kraff, O., Ladd, M. E., Forsting, M., & Wanke, I.
Venue
American Journal of Neuroradiology
Published
2009-01-15
Volume
30
Issue
4
Pages
699-702
ISSN
  • 0195-6108 (ISSN-L)
  • 1936-959X
OpenAlex
W2095270657
Cited by
193
References
4
FWCI
14.09
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.