Plasma Glucose, Insulin, Pancreatic, and Enteroglucagon Levels in Normal and Depancreatized Dogs
The DOI matches its Crossref record.
Abstract
Pancreatic glucagon (IRG), total glucagon-like immunoreactive material (GLI), enteroglucagon (calculated from GLI and IRG values), glucose, and insulin (IRI) were measured in the systemic plasma of normal and depancreatized dog. IRG, GLI, and enteroglucagon began to increase 1 or 2 days after pancreatectomy, respectively, reaching values that were several times greater than those observed before the operation. Glucose, already elevated 1 hr after pancreatectomy, continued to increase thereafter; IRI showed a progressive decline. In other experiments, 50 ml of a 5% glucose solution were injected into 30-cm loops prepared from the upper portion of the jejunum or the lower portion of the ileum and blood samples were obtained from the regional mesenteric veins. Plasma enteroglucagon rose more and plasma glucose less when glucose was introduced into the ileum than when it was introduced into the jejunum. The enteroglucagon responses to glucose were much greater in depancreatized than in normal dogs. In the depancreatized animals, a single injection of regular insulin (0.4 U/kg; im), sufficient to produce a significant elevation of the plasma IRI level but only a moderate decrease in plasma glucose, caused a prompt and significant decrease in the systemic plasma IRG, GLI, and enteroglucagon levels. We conclude that in the dogs, the ileum is a major source of enteroglucagon and that removal of the pancreas increases the secretion of this hormone, a phenomenon reversed in part by insulin therapy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Cherrington, A. D., Chiasson, J. L., Liljenquist, J. E., Jennings, A. S., Keller, U., & Lacy, W. W. (1976) · Journal of Clinical Investigation · doi:10.1172/jci108596 · Cited by 249
Gerich, J. E., Lorenzi, M., Bier, D. M., Tsalikian, E., Schneider, V, Karam, J. H., & Forsham, P. H. (1976) · Journal of Clinical Investigation · doi:10.1172/jci108364 · Cited by 198
The role of glucagon in the pathogenesis of the endogenous hyperglycemia of diabetes mellitus
Sakurai, H., Dobbs, R. E., & Unger, R. H. (1975) · Metabolism · doi:10.1016/0026-0495(75)90067-0 · Cited by 62
Abnormal Response of Pancreatic Glucagon to Glycemic Changes in Diabetes Mellitus
OHNEDA, A., WANTANABE, K., HORIGOME, K., SAKAI, T., KAI, Y., & OIKAWA, S.-I. (1978) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jcem-46-3-504 · Cited by 49
EJE PRIZE 2018: A gut feeling about glucagon
Knop, F. K. (2018) · European Journal of Endocrinology · doi:10.1530/eje-18-0197 · Cited by 47
Metadata
- Authors
- Matsuyama, T., & Foa, P. P.
- Venue
- Experimental Biology and Medicine
- Publisher
- Frontiers Media SA
- Published
- 1974-10-01
- Volume
- 147
- Issue
- 1
- Pages
- 97-102
- ISSN
- 0071-3384 (ISSN-L)
- 1535-3702
- 1535-3699
- OpenAlex
- W2323915642
- Cited by
- 107
- References
- 0
- FWCI
- 27.04
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.