Transmission of Mycobacterium chimaera from Heater–Cooler Units during Cardiac Surgery despite an Ultraclean Air Ventilation System
Open accessThe DOI matches its Crossref record.
Abstract
Heater-cooler units (HCUs) were recently identified as a source of Mycobacterium chimaera causing surgical site infections. We investigated transmission of this bacterium from HCUs to the surgical field by using a thermic anemometer and particle counter, videotape of an operating room equipped with an ultraclean laminar airflow ventilation system, and bacterial culture sedimentation plates in a nonventilated room. Smoke from the HCU reached the surgical field in 23 s by merging with ultraclean air. The HCU produced on average 5.2, 139, and 14.8 particles/min in the surgical field at positions Off, On/oriented toward, and On/oriented away, respectively. Culture plates were positive for M. chimaera <5 m from the HCU in the test room. These experiments confirm airborne transmission of M. chimaera aerosols from a contaminated HCU to an open surgical field despite ultraclean air ventilation. Efforts to mitigate infectious risks during surgery should consider contamination from water sources and airflow-generating devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
van Ingen, J., Kohl, T. A., Kranzer, K., Hasse, B., Keller, P. M., Katarzyna Szafrańska, A., Hillemann, D., Chand, M., Schreiber, P. W., Sommerstein, R., et al. (2017) · The Lancet Infectious Diseases · doi:10.1016/s1473-3099(17)30324-9 · Cited by 238
Self-citationBischoff, P., Kubilay, N. Z., Allegranzi, B., Egger, M., & Gastmeier, P. (2017) · The Lancet Infectious Diseases · doi:10.1016/s1473-3099(17)30059-2 · Cited by 203
2019 EACTS/EACTA/EBCP guidelines on cardiopulmonary bypass in adult cardiac surgery
Kunst, G., Milojevic, M., Boer, C., De Somer, F. M. J. J., Gudbjartsson, T., van den Goor, J., Jones, T. J., Lomivorotov, V., Merkle, F., Ranucci, M., et al. (2019) · British Journal of Anaesthesia · doi:10.1016/j.bja.2019.09.012 · Cited by 199
How to: identify non-tuberculous Mycobacterium species using MALDI-TOF mass spectrometry
Alcaide, F., Amlerová, J., Bou, G., Ceyssens, P. J., Coll, P., Corcoran, D., Fangous, M.-S., González-Álvarez, I., Gorton, R., Greub, G., et al. (2018) · Clinical Microbiology and Infection · doi:10.1016/j.cmi.2017.11.012 · Cited by 138
Metadata
- Authors
- Sommerstein, R., Rüegg, C., Kohler, P., Bloemberg, G., Kuster, S. P., & Sax, H.
- Venue
- Emerging Infectious Diseases
- Published
- 2016-06
- Volume
- 22
- Issue
- 6
- Pages
- 1008-1013
- ISSN
- 1080-6040 (ISSN-L)
- 1080-6059
- OpenAlex
- W2351731915
- Cited by
- 168
- References
- 0
- FWCI
- 27.81
- Type
- journal article
- Language
- en
- Open access
- diamond
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Transmission of Mycobacterium chimaera from Heater–Cooler Units during Cardiac Surgery despite an Ultraclean Air Ventilation System. https://app.cochat.ai/papers/10.3201/eid2206.160045
- The paper
- Sommerstein, R., Rüegg, C., Kohler, P., Bloemberg, G., Kuster, S. P., & Sax, H. (2016). Transmission of Mycobacterium chimaera from Heater–Cooler Units during Cardiac Surgery despite an Ultraclean Air Ventilation System. Emerging Infectious Diseases. https://doi.org/10.3201/eid2206.160045
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.