Effects of the non-Newtonian viscosity of blood on flows in a diseased arterial vessel. Part 1: Steady flows
The DOI matches its Crossref record.
Abstract
Effects of the non-Newtonian viscosity of blood on a flow in a coronary arterial casting of man were studied numerically using a finite element method. Various constitutive models were examined to model the non-Newtonian viscosity of blood and their model constants were summarized. A method to incorporate the non-Newtonian viscosity of blood was introduced so that the viscosity could be calculated locally. The pressure drop, wall shear stress and velocity profiles for the case of blood viscosity were compared for the case of Newtonian viscosity (0.0345 poise). The effect of the non-Newtonian viscosity of blood on the overall pressure drop across the arterial casting was found to be significant at a flow of the Reynolds number of 100 or less. Also in the region of flow separation or recirculation, the non-Newtonian viscosity of blood yields larger wall shear stress than the Newtonian case. The origin of the non-Newtonian viscosity of blood was discussed in relation to the viscoelasticity and yield stress of blood.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Non-Newtonian blood flow in human right coronary arteries: steady state simulations
Johnston, B. M., Johnston, P. R., Corney, S., & Kilpatrick, D. (2004) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2003.09.016 · Cited by 689
An Anatomically Based Model of Transient Coronary Blood Flow in the Heart
Smith, N. P., Pullan, A. J., & Hunter, P. J. (2002) · SIAM Journal on Applied Mathematics · doi:10.1137/s0036139999355199 · Cited by 339
Wentzel, J. J., Krams, R., Schuurbiers, J. C. H., Oomen, J. A., Kloet, J., van der Giessen, W. J., Serruys, P. W., & Slager, C. J. (2001) · Circulation · doi:10.1161/01.cir.103.13.1740 · Cited by 335
Rolled-up magnetic microdrillers: towards remotely controlled minimally invasive surgery
Xi, W., Solovev, A. A., Ananth, A. N., Gracias, D. H., Sanchez, S., & Schmidt, O. G. (2013) · Nanoscale · doi:10.1039/c2nr32798h · Cited by 284
Razavi, A., Shirani, E., & Sadeghi, M. R. (2011) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2011.04.023 · Cited by 257
On the Relative Importance of Rheology for Image-Based CFD Models of the Carotid Bifurcation
Lee, S.-W., & Steinman, D. A. (2007) · Journal of Biomechanical Engineering · doi:10.1115/1.2540836 · Cited by 190
Jain, A., Graveline, A., Waterhouse, A., Vernet, A., Flaumenhaft, R., & Ingber, D. E. (2016) · Nature Communications · doi:10.1038/ncomms10176 · Cited by 182
Molecular Sensors of Blood Flow in Endothelial Cells
Baratchi, S., Khoshmanesh, K., Woodman, O. L., Potocnik, S., Peter, K., & McIntyre, P. (2017) · Trends in Molecular Medicine · doi:10.1016/j.molmed.2017.07.007 · Cited by 179
Anand, M., Rajagopal, K., & Rajagopal, K. R. (2003) · Computational and Mathematical Methods in Medicine · doi:10.1080/10273660412331317415 · Cited by 175
“A review of the various 1-D single continuum models for blood, and the myriad expressions for its apparent viscosity, can be found in [47].”
BackgroundA quasi-mechanistic mathematical representation for blood viscosity.
Hund, S., Kameneva, M., & Antaki, J. (2017) · Fluids · doi:10.3390/fluids2010010 · Cited by 65
Vascular Dynamics of a Shape Memory Polymer Foam Aneurysm Treatment Technique
Ortega, J., Maitland, D., Wilson, T., Tsai, W., Savaş, Ö., & Saloner, D. (2007) · Annals of Biomedical Engineering · doi:10.1007/s10439-007-9358-y · Cited by 57
Metadata
- Authors
- Cho, Y. I., & Kensey, K. R.
- Venue
- Biorheology
- Publisher
- SAGE Publications
- Published
- 1991-06-01
- Volume
- 28
- Issue
- 3-4
- Pages
- 241-262
- ISSN
- 0006-355X (ISSN-L)
- 1878-5034
- OpenAlex
- W1457337077
- Cited by
- 823
- References
- 0
- FWCI
- 1.83
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.