Simulation of non-Newtonian blood flow in an end-to-side anastomosis
The DOI matches its Crossref record.
Abstract
In order to quantify the importance of non-Newtonian blood rheology on anastomotic flow patterns, the characteristics of Newtonian and non-Newtonian blood flows were compared in a 2-D, 45 degree end-to-side anastomosis model under both steady and unsteady flow conditions. All flows were assumed to be two-dimensional, and were simulated numerically using parameters consistent with blood flow in the femoral artery. A novel, purely viscous constitutive relation, based on a generalized form of the power law relation, was developed to model the non-Newtonian rheology of blood. The resulting wall shear stress patterns indicate that for the parameter values under consideration, non-Newtonian blood rheology has a significant effect on steady flow wall shear stresses, but no significant effect on unsteady flow wall shear stresses. Based on these and other simulations, a parameter is formulated that gives an indication of the importance of non-Newtonian blood rheology under a given set of flow conditions. In addition, an argument is presented for allowing the conclusions from this two-dimensional study to be extended to three-dimensional blood flow.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Non-Newtonian blood flow in human right coronary arteries: steady state simulations
Johnston, B. M., Johnston, P. R., Corney, S., & Kilpatrick, D. (2004) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2003.09.016 · Cited by 689
Wall Shear Stress: Theoretical Considerations and Methods of Measurement
Katritsis, D., Kaiktsis, L., Chaniotis, A., Pantos, J., Efstathopoulos, E. P., & Marmarelis, V. (2007) · Progress in Cardiovascular Diseases · doi:10.1016/j.pcad.2006.11.001 · Cited by 346
Milner, J. S., Moore, J. A., Rutt, B. K., & Steinman, D. A. (1998) · Journal of Vascular Surgery · doi:10.1016/s0741-5214(98)70210-1 · Cited by 276
Self-citationCompliance mismatch may promote graft–artery intimal hyperplasia by altering suture-line stresses
Ballyk, P. D., Walsh, C., Butany, J., & Ojha, M. (1997) · Journal of Biomechanics · doi:10.1016/s0197-3975(97)00111-5 · Cited by 272
Self-citationRazavi, A., Shirani, E., & Sadeghi, M. R. (2011) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2011.04.023 · Cited by 257
Steinman, D. A., Thomas, J. B., Ladak, H. M., Milner, J. S., Rutt, B. K., & Spence, J. D. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10025 · Cited by 255
Self-citationIntroductory biomechanics: from cells to organisms
(2007) · Choice Reviews Online · doi:10.5860/choice.45-1476 · Cited by 241
On the Relative Importance of Rheology for Image-Based CFD Models of the Carotid Bifurcation
Lee, S.-W., & Steinman, D. A. (2007) · Journal of Biomechanical Engineering · doi:10.1115/1.2540836 · Cited by 190
Self-citationA quasi-mechanistic mathematical representation for blood viscosity.
Hund, S., Kameneva, M., & Antaki, J. (2017) · Fluids · doi:10.3390/fluids2010010 · Cited by 65
Vascular Dynamics of a Shape Memory Polymer Foam Aneurysm Treatment Technique
Ortega, J., Maitland, D., Wilson, T., Tsai, W., Savaş, Ö., & Saloner, D. (2007) · Annals of Biomedical Engineering · doi:10.1007/s10439-007-9358-y · Cited by 57
Metadata
- Authors
- Ballyk, P. D., Steinman, D. A., & Ethier, C. R.
- Venue
- Biorheology
- Publisher
- SAGE Publications
- Published
- 1994-10-01
- Volume
- 31
- Issue
- 5
- Pages
- 565-586
- ISSN
- 0006-355X (ISSN-L)
- 1878-5034
- OpenAlex
- W2408903783
- Cited by
- 202
- References
- 0
- FWCI
- 1.21
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.