The DOI matches its Crossref record.
The cell-free layer in microvascular blood flow
Abstract
This review discusses the cell-free layer at the wall of the microcirculatory vessels with emphasis on the influence of blood rheological parameters on its formation as well as its possible effects on microvascular functions. Understanding cell-free layer characteristics in the microcirculation has been of increased interest for its possible influence on physiological function. The availability of better imaging and measurement techniques in recent years has created an excellent opportunity for researchers to examine the cell-free layer in much greater detail than possible previously. The most recent approach enables capturing spatial and temporal information of cell-free layer characteristics which can provide new insights to how cell-free layer width and its variations can impact physiological function. Cell-free layer formation is dependent on diameter of the vessel, flow rate, and rheological properties of blood including hematocrit, red blood cell aggregation, and deformability. Specifically in microvessels, its formation can also be affected by the presence of the glycocalyx layer that lines the luminal surface of the vessel wall. As the cell-free layer is omnipresent in microcirculatory vessels, its formation at the vessel wall could affect function throughout the microvascular network by altering wall shear stress, local hematocrit, flow distribution, effective viscosity and nitric oxide production as well as its scavenging by red blood cells.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Multifunctional surface microrollers for targeted cargo delivery in physiological blood flow
Alapan, Y., Bozuyuk, U., Erkoc, P., Karacakol, A. C., & Sitti, M. (2020) · Science Robotics · doi:10.1126/scirobotics.aba5726 · Cited by 414
Biomedical microfluidic devices by using low-cost fabrication techniques: A review
Faustino, V., Catarino, S. O., Lima, R., & Minas, G. (2016) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2015.11.031 · Cited by 338
Cerebral Hemodynamics and Vascular Risk Factors: Setting the Stage for Alzheimer's Disease
de la Torre, J. C. (2012) · Journal of Alzheimer's Disease · doi:10.3233/jad-2012-120793 · Cited by 219
Ta, H. T., Truong, N. P., Whittaker, A. K., Davis, T. P., & Peter, K. (2018) · Expert Opinion on Drug Delivery · doi:10.1080/17425247.2017.1316262 · Cited by 105
“At a fixed hematocrit, the RBC-FL thickness increases with an increase in vessel diameter therefore there is less RBCs-particle interaction near the wall [48, 53, 54].”
Background
Metadata
- Authors
- Kim, S., Ong, P. K., Yalcin, O., Intaglietta, M., & Johnson, P. C.
- Venue
- Biorheology
- Publisher
- SAGE Publications
- Published
- 2009
- Volume
- 46
- Issue
- 3
- Pages
- 181-189
- ISSN
- 0006-355X (ISSN-L)
- OpenAlex
- W1595561194
- Cited by
- 159
- References
- 0
- FWCI
- 6.10
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.