SIFT algorithm-based 3D pose estimation of femur
Open accessAbstract
To address the lack of 3D space information in the digital radiography of a patient femur, a pose estimation method based on 2D–3D rigid registration is proposed in this study. The method uses two digital radiography images to realize the preoperative 3D visualization of a fractured femur. Compared with the pure Digital Radiography or Computed Tomography imaging diagnostic methods, the proposed method has the advantages of low cost, high precision, and minimal harmful radiation. First, stable matching point pairs in the frontal and lateral images of the patient femur and the universal femur are obtained by using the Scale Invariant Feature Transform method. Then, the 3D pose estimation registration parameters of the femur are calculated by using the Iterative Closest Point (ICP) algorithm. Finally, based on the deviation between the six degrees freedom parameter calculated by the proposed method, preset posture parameters are calculated to evaluate registration accuracy. After registration, the rotation error is less than l.5°, and the translation error is less than 1.2 mm, which indicate that the proposed method has high precision and robustness. The proposed method provides 3D image information for effective preoperative orthopedic diagnosis and surgery planning.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Feature-based 2D/3D registration methods require features or anatomical landmarks that are specific to every object and must be selected with domain knowledge and be clearly visible in target images.
“However, these features and anatomical landmarks are specific to every object and must be selected with domain knowledge and such that they are clearly visible in the target images.”
From A Fully Differentiable Framework for 2D/3D Registration and the Projective Spatial Transformers (2024) · cites this paper as [9]
Section 2.1 describes 2D/3D femur registration using matching feature points, supporting the claim that this method uses image features. But Sections 2.1 and 3.2 say SIFT detects and matches those points; the paper does not say they must be selected with domain knowledge, are specific to every object, or must be clearly visible in target images. Page numbers are unavailable in our copy. (LLM, conf=0.83)
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Distinctive Image Features from Scale-Invariant Keypoints
Lowe, D. G. (2004) · International Journal of Computer Vision · doi:10.1023/b:visi.0000029664.99615.94 · Cited by 55,589 · see citing works
A Method for Registration of 3-D Shapes
Besl, P., & Mckay, N. D. (1992) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.121791 · Cited by 22,163 · see citing works
A flexible new technique for camera calibration
Zhang, Z. (2000) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.888718 · Cited by 15,004 · see citing works
Method for registration of 3-D shapes
Besl, P. J., & McKay, N. D. (1992) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.57955 · Cited by 2,448 · see citing works
Introduction to Biomedical Engineering
Goyal, A. S. (2005) · Elsevier eBooks · doi:10.1016/b978-0-12-238662-6.x5000-9 · Cited by 492 · see citing works
An outlook on x‐ray CT research and development
Wang, G., Yu, H., & Man, B. D. (2008) · Medical Physics · doi:10.1118/1.2836950 · Cited by 342 · see citing works
Semelka, R. C., Armao, D. M., Elías, J., & Huda, W. (2007) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20895 · Cited by 239 · see citing works
Introduction to Biomedical Engineering
Meldrum, S. J. (2000) · Physiological Measurement · doi:10.1088/0967-3334/21/2/701 · Cited by 216 · see citing works
Surgical and Interventional Robotics - Core Concepts, Technology, and Design [Tutorial]
Kazanzides, P., Gabor Fichtinger, A., Hager, G. D., Okamura, A. M., Whitcomb, L. L., & Taylor, R. H. (2008) · IEEE Robotics & Automation Magazine · doi:10.1109/mra.2008.926390 · Cited by 126 · see citing works
3D reconstruction of the human rib cage from 2D projection images using a statistical shape model
Dworzak, J., Lamecker, H., von Berg, J., Klinder, T., Cristian Lorenz, A., Kainmueller, D., Seim, H., Hege, H., & Stefan Zachow, A. (2009) · International Journal of Computer Assisted Radiology and Surgery · doi:10.1007/s11548-009-0390-2 · Cited by 58 · see citing works
Dumas, R., Blanchard, B., Carlier, R., de Loubresse, C. G., Huec, J. L., Marty, C., Moinard, M., & Vital, J.-M. (2007) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-007-0253-3 · Cited by 55 · see citing works
Computer-aided simulation for bone surgery
Caponetti, L., & Fanelli, A. M. (1993) · IEEE Computer Graphics and Applications · doi:10.1109/38.252561 · Cited by 52 · see citing works
2-D–3-D Frequency Registration Using a Low-Dose Radiographic System for Knee Motion Estimation
Jerbi, T., Burdin, V., Leboucher, J., Stindel, É., & Roux, C. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2188526 · Cited by 12 · see citing works
Intra-operative 3D pose estimation of fractured bone segments for image guided orthopedic surgery
Gamage, P. B., Xie, S. Q., Delmas, P. J., Xu, W., & Mukherjee, S. (2009) · IEEE International Conference on Robotics and Biomimetics (ROBIO) · doi:10.1109/robio.2009.4913018 · Cited by 7 · see citing works
Flagged first, then by citations
Research works printed but not linked: 1
- Haipeng, Liu, Jing Zhang, Dinghua Mao and Xinbo Zhao, Registration of the reconstructed CT slice model and CAD model based on the SVD-ICP algorithm, Computer Engineering and Applications 24 (2004), 060.
Cited by
Sorted by citations
A Fully Differentiable Framework for 2D/3D Registration and the Projective Spatial Transformers
Gao, C., Feng, A., Liu, X., Taylor, R. H., Armand, M., & Unberath, M. (2024) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2023.3299588 · Cited by 36 · see citing works
“Such examples include SIFT features for femur [9], Generalized Hough Transform (GHT) for spine vertebrae [10], learning-based shape encodings for metal implants [11], etc.”
MethodFiducial-Free 2D/3D Registration for Robot-Assisted Femoroplasty
Gao, C., Farvardin, A., Grupp, R. B., Bakhtiarinejad, M., Ma, L., Thies, M., Unberath, M., Taylor, R. H., & Armand, M. (2020) · IEEE Transactions on Medical Robotics and Bionics · doi:10.1109/tmrb.2020.3012460 · Cited by 36 · see citing works
Lee, D., Lee, D., & Han, B. (2016) · PLoS ONE · doi:10.1371/journal.pone.0153043 · Cited by 17 · see citing works
Automatic extraction of 3D anatomical feature curves of hip bone models reconstructed from CT images
Liu, H., Qian, H., & Zhao, J. (2015) · Bio-Medical Materials and Engineering · doi:10.3233/bme-151428 · Cited by 6 · see citing works
Self-citationResearch and Implementation of ORB-SLAM in Drastically Changing Scenes
Wang, Z., Wang, M., Yu, Y., & Ye, X. (2021) · IEEE Advanced Information Management, Communicates, Electronic and Automation Control Conference (IMCEC) · doi:10.1109/imcec51613.2021.9482292 · Cited by 1 · see citing works
Haseljić, H., Frysch, R., Kulvait, V., & Rose, G. (2019) · International Conference on Information, Communication and Automation Technologies (ICAT) · doi:10.1109/icat47117.2019.8938844
Ou, D., & Xiao, Y. (2025) · Nondestructive Testing And Evaluation · doi:10.1080/10589759.2025.2465418
A Real-Time System for Athlete Pose Analysis and Feedback Based on Machine Learning
Peng, X., Mao, X., & Fang, X. (2025) · Traitement du signal · doi:10.18280/ts.420649
Meta-reg: A meta-learning framework for generalizable intraoperative 2D/3D image registration
Xu, L., Kong, Q., Wang, X., Zhang, Y., & Xu, L. (2026) · Applied Soft Computing · doi:10.1016/j.asoc.2026.116093
- Authors
- Zhang, X., Zhu, Y., Li, C., Zhao, J., & Li, G.
- Affiliations
- Harbin Institute of Technology (CN)
- Corresponding author
- Li, Ge
- Venue
- Bio-Medical Materials and Engineering
- Publisher
- SAGE Publications
- Published
- 2014-11
- Volume
- 24
- Issue
- 6
- Pages
- 2847-2855
- ISSN
- 0959-2989 (ISSN-L)
- 1878-3619
- OpenAlex
- W1547389837
- Cited by
- 8
- References
- 14
- Citations by year
- 2026: 1 · 2025: 1 · 2023: 1 · 2021: 1 · 2020: 1 · 2019: 1 · 2016: 1 · 2015: 1
- FWCI
- 0.60
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- Locations
- Bio-Medical Materials and Engineering (publishedVersion, cc-by-nc)
- PubMed (publishedVersion)
- Funders
- State Key Laboratory of Robotics
- State Key Laboratory of Robotics and System
- Topics
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Medical Image Segmentation Techniques
- Physical Sciences › Engineering › Biomedical Engineering › Medical Imaging and Analysis
- Health Sciences › Medicine › Epidemiology › Bone fractures and treatments
- Keywords
- femur, 3D pose estimation, digital radiography, SIFT feature matching, iterative closest point, femoral fracture, preoperative surgical planning, 3D visualization, orthopedic diagnosis
- MeSH terms
- Algorithms, Femur, Humans, Radiographic Image Enhancement, Radiographic Image Interpretation, Computer-Assisted, Sensitivity and Specificity, Signal Processing, Computer-Assisted, Subtraction Technique, Tomography, X-Ray Computed, Reproducibility of Results, Imaging, Three-Dimensional, Patient Positioning
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review