CoChat

Molecular Gene Expression Testing to Identify Alzheimer’s Disease with High Accuracy from Fingerstick Blood

Open access
Seligmann, Bruce, Camiolo, Salvatore, Hernandez, Monica, Yeakley, Joanne M., Sahagian, Gregory, McComb, Joel · 2024 · Journal of Alzheimer's Disease

The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index; none of the 47 sources its claims cite is checked for support yet.

Abstract

Background: There is no molecular test for Alzheimer’s disease (AD) using self-collected samples, nor is there a definitive molecular test for AD. We demonstrate an accurate and potentially definitive TempO-Seq ® gene expression test for AD using fingerstick blood spotted and dried on filter paper, a sample that can be collected in any doctor’s office or can be self-collected. Objective: Demonstrate the feasibility of developing an accurate test for the classification of persons with AD from a minimally invasive sample of fingerstick blood spotted on filter paper which can be obtained in any doctor’s office or self-collected to address health disparities. Methods: Fingerstick blood samples from patients clinically diagnosed with AD, Parkinson’s disease (PD), or asymptomatic controls were spotted onto filter paper in the doctor’s office, dried, and shipped to BioSpyder for testing. Three independent patient cohorts were used for training/retraining and testing/retesting AD and PD classification algorithms. Results: After initially identifying a 770 gene classification signature, a minimum set of 68 genes was identified providing classification test areas under the ROC curve of 0.9 for classifying patients as having AD, and 0.94 for classifying patients as having PD. Conclusions: These data demonstrate the potential to develop a screening and/or definitive, minimally invasive, molecular diagnostic test for AD and PD using dried fingerstick blood spot samples that are collected in a doctor’s office or clinic, or self-collected, and thus, can address health disparities. Whether the test can classify patients with AD earlier then possible with cognitive testing remains to be determined.

Overview

CoChat Summary

TL;DR

This study reports a TempO-SeqDBS gene expression assay using fingerstick blood dried on filter paper to classify Alzheimer’s disease (AD) and Parkinson’s disease (PD). A minimal 68-gene SVM classifier achieved ROC-AUC 0.9 for AD and 0.94 for PD across three cohorts, with 98% accuracy across 106 samples.

Key findings

  • The TempO-SeqDBS assay successfully profiled whole-transcriptome gene expression from fingerstick blood spotted and dried on filter paper; replicate Pearson correlations were significant at p < 0.05, and same-donor samples tested over 400 days showed reproducibility.
  • An initial 770-gene signature was identified; pathway analysis showed predominant immune response pathways, with the three most significant pathways related to neutrophil involvement in immune and inflammatory response.
  • A minimal 68-gene signature using a linear SVM model (kernel = linear, gamma = 0.1, c = 0.001) yielded ROC-AUCAD = 0.9 and ROC-AUCPD = 0.94 across cohorts A, B, and C, with 98% accuracy across all 106 samples (two misclassified).
  • Among 12 AD patients with available Aβ PET scores, all 12 were classified as AD by TempO-SeqDBS, including 9 Aβ PET-positive and 3 Aβ PET-negative; one PD patient with positive Aβ PET and DaTscan was classified as PD.

Methods

  • Fingerstick blood (2–3 drops) was spotted onto Whatman filter paper, air-dried, de-identified, shipped, and punched (two 1.6 mm areas per well, four replicate wells per patient). Samples were lysed and tested with the commercial TempO-Seq Whole Transcriptome Whole Blood assay v2.1 measuring ∼21,000 genes, sequenced on Illumina NextSeq to ∼6 M reads/sample; QC removed replicates with Pearson R < 0.9, requiring at least 3 remaining replicates/sample.
  • Patients clinically diagnosed with AD or PD and asymptomatic controls were consented under an IRB-approved protocol at the Neurology Center of Southern California. AD diagnosis followed NIA-AA 2011 guidance; PD diagnosis followed UK Parkinson’s Disease Society Brain Bank guidance. Three independent patient cohorts were used for training/retraining and testing/retesting AD and PD classification algorithms.
  • Machine learning approaches included k-nearest neighbors, random forest, SVM with linear, polynomial, or RBF kernels, and XGBoost, with hyperparameters tuned by random grid. Random 80% subsets trained classifiers tested on remaining 20%; the linear SVM performed best. Gene selection used 100 random training sets, cumulative weight scores, and ROC curves for top-scoring genes, yielding a final 68-gene signature.

Limitations

  • The paper states the risk of overfitting from small sample sizes; the number of PD samples was more limiting and will be the focus of follow-up. Aβ PET scores were available for only 12 (24%) of 50 clinically diagnosed AD patients, and a much larger cohort with Aβ PET and DaTscan data is needed to confirm conclusions.
  • The paper states that longitudinal samples are needed to determine how early in AD progression the test can classify patients, whether classification occurs before biomarker or Aβ PET positivity, and whether all classified patients eventually become biomarker and Aβ PET positive. It also states there are no data on whether gene expression changes are connected to disease progression or response, and whole blood single-cell studies are planned to identify contributing cells.
  • Evident from the text: all samples came from a single Neurology Center of Southern California, and the paper does not report blinding or validation at independent external sites, which may limit generalizability.

Model-written summary. Check it against the paper before relying on it.

Integrity signals

Registry

Crossref · 10.3233/jad-240174

Cites

28 of 28 references verified0 citation errors · 0 not checkable

Statistics

Nothing to recompute.

Figures

Fig. 1 Histogram showing the distribution of the Pearson r correlation between replicates as a measure of reproducibility. Four different areas of the filter paper spotted with finger stick blood from each donor were tested as replicates. The Pearson correlations between all the possible pairwise comparisons between the replicates for each donor sample were calculated after log transforming the data, and the results depicted as a histogram of the number of samples grouped into each Pearson coefficient value.
Fig. 1 Histogram showing the distribution of the Pearson r correlation between replicates as a measure of reproducibility. Four different areas of the filter paper spotted with finger stick blood from each donor were tested as replicates. The Pearson correlations between all the possible pairwise comparisons between the replicates for each donor sample were calculated after log transforming the data, and the results depicted as a histogram of the number of samples grouped into each Pearson coefficient value.CC BY-NC · PubMed Central
Fig. 2 Pearson r correlation of log-transformed counts to quantify reproducibility of gene expression measurement from the same donor, different days. Samples from the same donor were spotted and tested on different days as controls over a period of 400 days. The replicates for the same time point were averaged and the average log transformed values were correlated using the Pearson correlation, comparing days 0, 7, 15, 24, 30, and 400. The Pearson correlations are indicated as the values of the heatmap.
Fig. 2 Pearson r correlation of log-transformed counts to quantify reproducibility of gene expression measurement from the same donor, different days. Samples from the same donor were spotted and tested on different days as controls over a period of 400 days. The replicates for the same time point were averaged and the average log transformed values were correlated using the Pearson correlation, comparing days 0, 7, 15, 24, 30, and 400. The Pearson correlations are indicated as the values of the heatmap.CC BY-NC · PubMed Central
Fig. 3 Gene expression pathway analysis. The differentially expressed genes in the AD classifier signature were used to carry out analysis of what molecular pathways were differentially expressed. Gene set enrichment was performed using the Gene Ontology database for biological processes with a p value threshold of 0.05. The 20 most significant identified pathways are depicted, ranked by log adjusted p value for each.
Fig. 3 Gene expression pathway analysis. The differentially expressed genes in the AD classifier signature were used to carry out analysis of what molecular pathways were differentially expressed. Gene set enrichment was performed using the Gene Ontology database for biological processes with a p value threshold of 0.05. The 20 most significant identified pathways are depicted, ranked by log adjusted p value for each.CC BY-NC · PubMed Central
Fig. 4 ROC Curve for classification of Cohort A samples as AD and PD. The ROC curves are shown for the classification of patient samples as AD or PD using the Support Vector Machine (SVM) model (kernel = linear, gamma = 0.1, c = 0.001) and the initially identified 770 gene signature. Use of this model resulted in the best performance for the classification of both AD (ROC-AUCAD = 0.81), and for PD (ROC-AUCPD = 0.86). The model was trained using 80% each of the control, AD, and PD samples in cohort A. As a test for classification accuracy, the trained model was used to classify the remaining 20% of samples. The resulting ROC-AUC vales were 0.81 for AD and 0.88 for PD.
Fig. 4 ROC Curve for classification of Cohort A samples as AD and PD. The ROC curves are shown for the classification of patient samples as AD or PD using the Support Vector Machine (SVM) model (kernel = linear, gamma = 0.1, c = 0.001) and the initially identified 770 gene signature. Use of this model resulted in the best performance for the classification of both AD (ROC-AUCAD = 0.81), and for PD (ROC-AUCPD = 0.86). The model was trained using 80% each of the control, AD, and PD samples in cohort A. As a test for classification accuracy, the trained model was used to classify the remaining 20% of samples. The resulting ROC-AUC vales were 0.81 for AD and 0.88 for PD.CC BY-NC · PubMed Central
Fig. 5 ROC Curve for Classification of the combined Cohort A and B samples. The ROC curves for the classification of patient samples using the Support Vector Machine (SVM) model (kernel = linear, gamma = 0.1, c = 0.001) and the initially identified 770 gene signature are depicted after pooling together Cohorts A and B to provide a sample set of 106 samples, training with 80% of the samples, and testing with the remaining 20%. For this combined cohort, the ROC-AUC was 0.86 for Ad and 0.87 for PD.
Fig. 5 ROC Curve for Classification of the combined Cohort A and B samples. The ROC curves for the classification of patient samples using the Support Vector Machine (SVM) model (kernel = linear, gamma = 0.1, c = 0.001) and the initially identified 770 gene signature are depicted after pooling together Cohorts A and B to provide a sample set of 106 samples, training with 80% of the samples, and testing with the remaining 20%. For this combined cohort, the ROC-AUC was 0.86 for Ad and 0.87 for PD.CC BY-NC · PubMed Central
Fig. 6 ROC Curve for classification of Cohort A, B, and C samples as AD and PD, 68 gene signature. The ROC curves are shown for the classification of patient samples as AD or PD using the Support Vector Machine (SVM) model (kernel = linear, gamma = 0.1, c = 0.001) and minimal 68 gene signature. The model was trained using 80% each of the control, AD, and PD samples in cohorts A, B, and C. As a test for classification accuracy, the trained model was used to classify the remaining 20% of samples. The resulting ROC-AUC values were 0.9 for AD and 0.94 for PD.
Fig. 6 ROC Curve for classification of Cohort A, B, and C samples as AD and PD, 68 gene signature. The ROC curves are shown for the classification of patient samples as AD or PD using the Support Vector Machine (SVM) model (kernel = linear, gamma = 0.1, c = 0.001) and minimal 68 gene signature. The model was trained using 80% each of the control, AD, and PD samples in cohorts A, B, and C. As a test for classification accuracy, the trained model was used to classify the remaining 20% of samples. The resulting ROC-AUC values were 0.9 for AD and 0.94 for PD.CC BY-NC · PubMed Central

Verification

Claims the paper makes

0 Valid · 0 Not valid · 19 Not checked · 47 Own results and interpretations

29 more claims

Create a free account to see all 66 claims and to verify the 39 references still open.

See all claims — free account
  • It may state two separate claims as one. 24
  • The quote only partly states this claim. 1
  • Probably not a substantial claim. 12

Create a free account to see these claims.

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

Each contradiction between two passages listed here was confirmed by an independent check.

3 of 3

Citations

Cites

Show all 28 references

Cited by

See all 7

Metadata

Authors
Seligmann, B., Camiolo, S., Hernandez, M., Yeakley, J. M., Sahagian, G., & McComb, J.
Affiliations
  • Biospyder (United States) (US)
  • Neurology Center of Southern California (US)
Corresponding author
Seligmann, Bruce
Venue
Journal of Alzheimer's Disease
Published
2024-09-11
Volume
101
Issue
3
Pages
813-822
ISSN
  • 1387-2877 (ISSN-L)
  • 1875-8908
OpenAlex
W4402514028
Cited by
7
References
28
Citations by year
2026: 3 · 2025: 4
FWCI
1.31
Type
journal article
Language
en
Open access
Licence
  • cc-by-nc
  • journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
Locations
  • Journal of Alzheimer s Disease (publishedVersion, cc-by-nc)
  • PubMed Central (publishedVersion, cc-by-nc)
  • PubMed (publishedVersion)
Funders
  • National Institutes of Health (1r43ag065039-01)
  • National Institute on Aging (R44AG065039)
Topics
  • Health Sciences › Medicine › Psychiatry and Mental health › Dementia and Cognitive Impairment Research
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Alzheimer's disease research and treatments
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Molecular Biology Techniques and Applications
Keywords
Alzheimer's disease, Parkinson's disease
MeSH terms
Aged, Aged, 80 and over, Alzheimer Disease, Blood Specimen Collection, Female, Humans, Male, Middle Aged, Parkinson Disease, Gene Expression Profiling

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

A language model drew the claims from the paper on 2026-11-26, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).

A second model labelled each claim on 2026-11-26 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Molecular Gene Expression Testing to Identify Alzheimer’s Disease with High Accuracy from Fingerstick Blood. https://app.cochat.ai/papers/10.3233/jad-240174
The paper
Seligmann, B., Camiolo, S., Hernandez, M., Yeakley, J. M., Sahagian, G., & McComb, J. (2024). Molecular Gene Expression Testing to Identify Alzheimer’s Disease with High Accuracy from Fingerstick Blood. Journal of Alzheimer's Disease. https://doi.org/10.3233/jad-240174

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.