Consideration of nerve-muscle grafts to improve the control of artificial arms
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Improving the function of artificial arms remains a considerable challenge, especially for high-level amputations where the disability is greatest. It may be possible to denervate expendable regions of muscle in or near an amputated limb and graft th
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A new strategy for multifunction myoelectric control
Hudgins, B., Parker, P., & Scott, R. N. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.204774 · Cited by 2,149 · cited 1×
“Recent studies have utilized neural networks [15], fuzzy logic [3] and wavelet based classification techniques [8].”
A wavelet-based continuous classification scheme for multifunction myoelectric control
Englehart, K., Hudgin, B., & Parker, P. A. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.914793 · Cited by 697 · cited 1×
“Recent studies have utilized neural networks [15], fuzzy logic [3] and wavelet based classification techniques [8].”
Edell, D. J. (1986) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1986.325892 · Cited by 177 · cited 1×
“With neuroelectric control, electrodes are directly connected to the residual nerves of the amputee and the electroneurogram (ENG) of the nerve is used to con-trol the artificial limb [2,5,7,14].”
Cited by
Targeted Muscle Reinnervation for Real-time Myoelectric Control of Multifunction Artificial Arms
Kuiken, T. A. (2009) · JAMA · doi:10.1001/jama.2009.116 · Cited by 1,089
Self-citationKuiken, T. A., Marasco, P. D., Lock, B. A., Harden, R. N., & Dewald, J. P. A. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0706525104 · Cited by 283
Self-citationProsthetic Myoelectric Control Strategies: A Clinical Perspective
Roche, A. D., Rehbaum, H., Farina, D., & Aszmann, O. C. (2014) · Current Surgery Reports · doi:10.1007/s40137-013-0044-8 · Cited by 261
Decoding a New Neural–Machine Interface for Control of Artificial Limbs
Zhou, P., Lowery, M. M., Englehart, K. B., Huang, H., Li, G., Hargrove, L., Dewald, J. P. A., & Kuiken, T. A. (2007) · Journal of Neurophysiology · doi:10.1152/jn.00178.2007 · Cited by 215
Self-citationTargeted Muscle Reinnervation for the Upper and Lower Extremity
Kuiken, T. A., Barlow, A. K., Hargrove, L. J., & Dumanian, G. A. (2017) · Techniques in Orthopaedics · doi:10.1097/bto.0000000000000194 · Cited by 143
Self-citation
Metadata
- Authors
- Kuiken, T.
- Venue
- Technology and Disability
- Publisher
- SAGE Publications
- Published
- 2003-08-27
- Volume
- 15
- Issue
- 2
- Pages
- 105-111
- ISSN
- 1055-4181 (ISSN-L)
- 1878-643X
- OpenAlex
- W1615610719
- Cited by
- 39
- References
- 3
- FWCI
- 0.77
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Consideration of nerve-muscle grafts to improve the control of artificial arms. https://app.cochat.ai/papers/10.3233/tad-2003-15206
- The paper
- Kuiken, T. (2003). Consideration of nerve-muscle grafts to improve the control of artificial arms. Technology and Disability. https://doi.org/10.3233/tad-2003-15206
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.