A Peripheral Nerve Information Transducer for Amputees: Long-Term Multichannel Recordings from Rabbit Peripheral Nerves
Abstract
A micromachined silicon technology is being developed for the purpose of sensing information from the stumps of amputated mammalian peripheral nerves. Information on long-term biocompatibility, anatomy, and physiology related to the structural design of this sensor is presented. Pertinent materials, fabrication, and surgical implantation issues are discussed. Noise, signal amplitude, and receptive field are considered as the prime determinants of the design of an appropriate electrode contact geometry for the structure. The selectivity of the device is also discussed in terms of the fine structure of the regenerated nerve. Examples of waveforms recorded from rabbit peripheral nerves using this sensor are presented and discussed in terms of electrical and physiological parameters. Possible use of the sensor as a source for a binary code suitable for communication of information to a computer is presented along with discussion of the limitations of the current technology and possible future applications.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Regenerating axons grow through the holes of regenerative electrodes, making it possible to record action potentials from and stimulate individual axons or small fascicles.
“Regenerating axons eventually grow through the holes (Fig. 12), making it possible to record action potentials from and to stimulate individual axons or small fascicles.”
From A critical review of interfaces with the peripheral nervous system for the control of neuroprostheses and hybrid bionic systems (2005) · cites this paper as Edell, 1986
Regenerative electrodes are designed to interface a high number of nerve fibers using an array of holes with electrodes built around them, implanted between the severed stumps of a peripheral nerve.
“Regenerative electrodes are designed to interface a high number of nerve fibers by using an array of holes, with electrodes built around them, implanted between the severed stumps of a peripheral nerve (Llina ´ s et al., 1973; Edell, 1986; Kovacs et al., 1992; Dario et al., 1998) .”
From A critical review of interfaces with the peripheral nervous system for the control of neuroprostheses and hybrid bionic systems (2005) · cites this paper as Edell, 1986
Silicon regenerative interfaces cause frequent signs of axonopathy and constitute a physical barrier that limits elongation of regenerating axons depending on the size of the holes.
“However, such silicon interfaces cause frequent signs of axonopathy and constitute a physical barrier that limits the elongation of regenerating axons depending on the size of the holes (Edell, 1986; Rosen et al., 1990; Navarro et al., 1996; Zhao et al., 1997) .”
From A critical review of interfaces with the peripheral nervous system for the control of neuroprostheses and hybrid bionic systems (2005) · cites this paper as Edell, 1986
A one-to-one design allowing access to each individual regenerated axon through one hole of 2-10 μm diameter has proved impossible, because nerve regeneration fails with holes of such small size.
“Ideally a one-to-one design would allow access to each individual regenerated axon grown through one hole (2-10 m m in diameter). However, this has been proved impossible; nerve regeneration fails with holes of such small size.”
From A critical review of interfaces with the peripheral nervous system for the control of neuroprostheses and hybrid bionic systems (2005) · cites this paper as Edell, 1986
Efferent neural signals recorded from regenerative electrodes can be used to control the motion of a mechanical prosthesis.
“recording of neural efferent signals can be used for the motion control of a mechanical prosthesis (Edell, 1986)”
From A critical review of interfaces with the peripheral nervous system for the control of neuroprostheses and hybrid bionic systems (2005) · cites this paper as Edell, 1986
Cites
Simpson, J. A. (1979) · Journal of Neurology Neurosurgery & Psychiatry · doi:10.1136/jnnp.42.6.580 · Cited by 676 · see citing works
Principles of Applied Biomedical Instrumentation.
(1975) · Annals of Internal Medicine · doi:10.7326/0003-4819-83-6-924_2 · Cited by 561 · see citing works
An Integrated-Circuit Approach to Extracellular Microelectrodes
Wise, K. D., Angell, J. B., & Starr, A. (1970) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1970.4502738 · Cited by 544 · see citing works
The Interfascicular Nerve-Grafting of the Median and Ulnar Nerves
Millesi, H., Meissl, G., & Berger, A. (1972) · Journal of Bone and Joint Surgery · doi:10.2106/00004623-197254040-00004 · Cited by 496 · see citing works
Tasaki, I. (1955) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1955.181.3.639 · Cited by 222 · see citing works
Principles Underlying New Methods for Chronic Neural Recording
Stein, R. B., Charles, D., DAVIS, L. A., Jhamandas, J. H., Mannard, A., & Nichols, T. R. (1975) · Canadian Journal of Neurological Sciences / Journal Canadien des Sciences Neurologiques · doi:10.1017/s0317167100020333 · Cited by 211 · see citing works
Ranvier, L. A. (1875) · Biblioteca Digital (Real Academia Nacional de Medicina) · Cited by 163 · see citing works
Facility of motor unit control during tasks defined directly in terms of unit behaviors
Thomas, J., Schmidt, E. M., & Hambrecht, F. T. (1978) · Experimental Neurology · doi:10.1016/0014-4886(78)90230-3 · Cited by 137 · see citing works
Loeb, G. E., Walker, A. E., Uematsu, S., & Konigsmark, B. W. (1977) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820110206 · Cited by 95 · see citing works
Mannard, A., Stein, R. B., & Charles, D. (1974) · Science · doi:10.1126/science.183.4124.547 · Cited by 85 · see citing works
Structure and Sodium Migration in Silicon Nitride Films
Dalton, J., & Drobek, J. (1968) · Journal of The Electrochemical Society · doi:10.1149/1.2411450 · Cited by 67 · see citing works
Loeb, G. E., Marks, W. B., & Beatty, P. G. (1977) · Medical & Biological Engineering & Computing · doi:10.1007/bf02442964 · Cited by 46 · see citing works
Packaging Materials and Techniques for Implantable Instruments
Ko, W. H., & Spear, T. M. (1983) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/emb-m.1983.5005879 · Cited by 43 · see citing works
Distinguishability of Functionally Distinct Evoked Neuroelectric Signals on the Surface of a Nerve
Lichtenberg, B. K., & Luca, C. J. D. (1979) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1979.326507 · Cited by 36 · see citing works
An Evaluation of Photoengraved Microelectrodes for Extracellular Single-Unit Recording
Starr, A., Wise, K. D., & Csongradi, J. (1973) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1973.324194 · Cited by 34 · see citing works
Biocompatibility of a Silicon Based Peripheral Nerve Electrode
Edell, D. J., Churchill, J. N., & Gourley, I. M. (1982) · Biomaterials Medical Devices and Artificial Organs · doi:10.3109/10731198209118775 · Cited by 32 · see citing works
Self-citationManagement of Peripheral Nerve Problems
Weeks, P. M. (1981) · Plastic & Reconstructive Surgery · doi:10.1097/00006534-198110000-00034 · Cited by 30 · see citing works
Voluntary Nerve Signals from Severed Mammalian Nerves: Long-Term Recordings
Luca, C. J. D., & Gilmore, L. D. (1976) · Science · doi:10.1126/science.1246608 · Cited by 25 · see citing works
A comparison of manual reaction times as measured by three sensitive indices
Bartlett, N. R. (1963) · The Psychological Record · doi:10.1007/bf03393501 · Cited by 25 · see citing works
The interfascicular nerve-grafting of median and ulnar nerves
Millesi, H., Meissl, G., & Berger, A. (1973) · Plastic & Reconstructive Surgery · doi:10.1097/00006534-197302000-00061 · Cited by 24 · see citing works
An action potential study of neuromuscular relations.
Hathaway, S. R. (1935) · Journal of Experimental Psychology · doi:10.1037/h0062301 · Cited by 21 · see citing works
An action current study of the conditioned hand withdrawal.
Hilden, A. H. (1937) · The Psychological Monographs · doi:10.1037/h0093441 · Cited by 16 · see citing works
Long-Term Peripheral Nerve Activity During Behavior in the Rabbit
Hoffer, J. A., & Marks, W. B. (1976) · Advances in behavioral biology · doi:10.1007/978-1-4757-0964-3_32 · Cited by 12 · see citing works
Comparison of Electromyographic and Microswitch Measures of Auditory Reaction Time
Costa, L. D., Vaughan, H. G., & Gilden, L. (1965) · Perceptual and Motor Skills · doi:10.2466/pms.1965.20.3.771 · Cited by 11 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Targeted Muscle Reinnervation for Real-time Myoelectric Control of Multifunction Artificial Arms
Kuiken, T. A. (2009) · JAMA · doi:10.1001/jama.2009.116 · Cited by 1,089 · see citing works
Campbell, P. K., Jones, K. E., Huber, R. J., Horch, K. W., & Normann, R. A. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.83588 · Cited by 881 · see citing works
Navarro, X., Krueger, T. B., Lago, N., Micera, S., Stieglitz, T., & Dario, P. (2005) · Journal of the Peripheral Nervous System · doi:10.1111/j.1085-9489.2005.10303.x · Cited by 845 · see citing works
Wireless Implantable Microsystems: High-Density Electronic Interfaces to the Nervous System
Wise, K. D., Anderson, D. J., Hetke, J. F., Kipke, D. R., & Najafi, K. (2004) · Proceedings of the IEEE · doi:10.1109/jproc.2003.820544 · Cited by 656 · see citing works
Implanted Neural Interfaces: Biochallenges and Engineered Solutions
Grill, W. M., Norman, S. E., & Bellamkonda, R. V. (2009) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-061008-124927 · Cited by 488 · see citing works
Factors influencing the biocompatibility of insertable silicon microshafts in cerebral cortex
Edell, D. J., Toi, V. V., McNeil, V. M., & Clark, L. D. (1992) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.141202 · Cited by 479 · see citing works
Self-citationForeign Body Reaction to Implanted Biomaterials and Its Impact in Nerve Neuroprosthetics
Carnicer-Lombarte, A., Chen, S.-T., Malliaras, G. G., & Barone, D. G. (2021) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2021.622524 · Cited by 454 · see citing works
“Early sieve electrode designs were fabricated from rigid silicon wafers perforated with an array of holes, each of which contained an electrode (Edell, 1986; Akin et al., 1994; Navarro et al., 1996).”
BackgroundA spiral nerve cuff electrode for peripheral nerve stimulation
Naples, G. G., Mortimer, J. T., Scheiner, A., & Sweeney, J. D. (1988) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.8670 · Cited by 415 · see citing works
Control of Hand Prostheses Using Peripheral Information
Micera, S., Carpaneto, J., & Raspopović, S. (2010) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2010.2085429 · Cited by 405 · see citing works
Single unit recording capabilities of a 100 microelectrode array
Nordhausen, C. T., Maynard, E. M., & Normann, R. A. (1996) · Brain Research · doi:10.1016/0006-8993(96)00321-6 · Cited by 358 · see citing works
Micromachined, Polyimide-Based Devices for Flexible Neural Interfaces
Stieglitz, T., Beutel, H., Schuettler, M., & Meyer, J.-U. (2000) · Biomedical Microdevices · doi:10.1023/a:1009955222114 · Cited by 343 · see citing works
Nerve regeneration through artificial tubular implants
Fields, R. D., Beau, J. M. L., Longo, F. M., & Ellisman, M. H. (1989) · Progress in Neurobiology · doi:10.1016/0301-0082(89)90036-1 · Cited by 308 · see citing works
Selective Electrical Interfaces with the Nervous System
Rutten, W. L. C. (2002) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.4.020702.153427 · Cited by 276 · see citing works
Flexible and stretchable micro-electrodes for in vitro and in vivo neural interfaces
Lacour, S. P., Benmerah, S., Tarte, E. J., FitzGerald, J. J., Serra, J., McMahon, S. B., Fawcett, J. W., Graudejus, O., Yu, Z., & Morrison, B. (2010) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-010-0644-8 · Cited by 265 · see citing works
Dhillon, G. S., Krüger, T. B., Sandhu, J. S., & Horch, K. W. (2005) · Journal of Neurophysiology · doi:10.1152/jn.00937.2004 · Cited by 183 · see citing works
Lago, N., Ceballos, D., J Rodrı́guez, F., Stieglitz, T., & Navarro, X. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.06.025 · Cited by 178 · see citing works
A dry electrode for EEG recording
Taheri, B. A., Knight, R. T., & Smith, R. L. (1994) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(94)90053-1 · Cited by 177 · see citing works
Implantable neurotechnologies: a review of micro- and nanoelectrodes for neural recording
Patil, A. C., & Thakor, N. V. (2016) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-015-1430-4 · Cited by 175 · see citing works
Chronically implanted intrafascicular recording electrodes
Lefurge, T., Goodall, E., Horch, K., Stensaas, L., & Schoenberg, A. (1991) · Annals of Biomedical Engineering · doi:10.1007/bf02368469 · Cited by 172 · see citing works
Robotics for medical applications
Dario, P., Guglielmelli, E., Allotta, B., & Carrozza, M. C. (1996) · IEEE Robotics & Automation Magazine · doi:10.1109/100.540149 · Cited by 169 · see citing works
Regeneration microelectrode array for peripheral nerve recording and stimulation
Kovacs, G. T. A., Storment, C. W., & Rosen, J. M. (1992) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.256422 · Cited by 164 · see citing works
An Extracellular microelectrode Array for monitoring electrogenic cells in culture
Connolly, P., Clark, P., Curtis, A. S. G., Dow, J. A. T., & Wilkinson, C. D. W. (1990) · Biosensors and Bioelectronics · doi:10.1016/0956-5663(90)80011-2 · Cited by 162 · see citing works
A micromachined silicon sieve electrode for nerve regeneration applications
Akin, T., Najafi, K., Smoke, R. H., & Bradley, R. M. (1994) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.284958 · Cited by 144 · see citing works
Kovacs, G. T. A., Storment, C. W., Halks-Miller, M., Belczynski, C. R., Santina, C. C. D., Lewis, E. R., & Maluf, N. I. (1994) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.293244 · Cited by 161 · see citing works
A review for the peripheral nerve interface designer
Larson, C. E., & Meng, E. (2020) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2019.108523 · Cited by 133 · see citing works
Sensitivity and selectivity of intraneural stimulation using a silicon electrode array
Rutten, W. L. C., van Wier, H. J., & Put, J. H. M. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.76386 · Cited by 129 · see citing works
A flexible perforated microelectrode array for extended neural recordings
Boppart, S. A., Wheeler, B. C., & Wallace, C. S. (1992) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.108125 · Cited by 126 · see citing works
Stieglitz, T., Beutel, H., & Meyer, J.-U. (1997) · Sensors and Actuators A: Physical · doi:10.1016/s0924-4247(97)01494-5 · Cited by 125 · see citing works
Lee, J. H., Kim, H., Kim, J. H., & Lee, S. (2016) · Lab on a Chip · doi:10.1039/c5lc00842e · Cited by 124 · see citing works
Micera, S., Navarro, X., Carpaneto, J., Citi, L., Tonet, O., Rossini, P. M., Carrozza, M. C., Hoffmann, K. P., Vivo, M., Yoshida, K., et al. (2008) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2008.2006207 · Cited by 120 · see citing works
Neuman, M. R. (1999) · The electrical engineering handbook/Electrical engineering handbook series/Electrical engineering handbook · doi:10.1201/9781420049510.ch48 · Cited by 116 · see citing works
Cho, S., Lu, H., Cauller, L. J., Romero‐Ortega, M. I., Lee, J., & Hughes, G. A. (2008) · IEEE Sensors Journal · doi:10.1109/jsen.2008.2006261 · Cited by 112 · see citing works
A micromachined silicon depth probe for multichannel neural recording
Yoon, T. H., Hwang, E. J., Shin, D. Y., Park, S. I., Oh, S., Jung, S. C., Shin, H. C., & Kim, S. J. (2000) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.855936 · Cited by 110 · see citing works
A slowly penetrating interfascicular nerve electrode for selective activation of peripheral nerves
Tyler, D. J., & Durand, D. M. (1997) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.559349 · Cited by 108 · see citing works
Lawrence, S. M., Dhillon, G. S., Jensen, W., Yoshida, K., & Horch, K. W. (2004) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2004.831491 · Cited by 106 · see citing works
Targeted Reinnervation for Improved Prosthetic Function
Kuiken, T. (2006) · Physical Medicine and Rehabilitation Clinics of North America · doi:10.1016/j.pmr.2005.10.001 · Cited by 106 · see citing works
Neural machine interfaces for controlling multifunctional powered upper-limb prostheses
Ohnishi, K., Weir, R. F. F., & Kuiken, T. (2006) · Expert Review of Medical Devices · doi:10.1586/17434440.4.1.43 · Cited by 103 · see citing works
Riso, R. R. (1999) · Technology and Health Care · doi:10.3233/thc-1999-7604 · Cited by 98 · see citing works
Interfacing the Somatosensory System to Restore Touch and Proprioception: Essential Considerations
Weber, D. J., Friesen, R., & Miller, L. E. (2012) · Journal of Motor Behavior · doi:10.1080/00222895.2012.735283 · Cited by 98 · see citing works
Advantages of using microfabricated extracellular electrodes for in vitro neuronal recording
Breckenridge, L. J., Wilson, R. J. A., Connolly, P., Curtis, A. S. G., Dow, J. A. T., Blackshaw, S. E., & Wilkinson, C. D. W. (1995) · Journal of Neuroscience Research · doi:10.1002/jnr.490420215 · Cited by 98 · see citing works
Tissue-engineered peripheral nerve interfaces
Spearman, B. S., Desai, V. H., Mobini, S., McDermott, M. D., Graham, J. B., Otto, K. J., Judy, J. W., & Schmidt, C. E. (2018) · Advanced Functional Materials · doi:10.1002/adfm.201701713 · Cited by 96 · see citing works
Fabrication and characteristics of an implantable, polymer-based, intrafascicular electrode
Lawrence, S. M., Dhillon, G. S., & Horch, K. W. (2003) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(03)00231-0 · Cited by 93 · see citing works
The Motor Cortex and Its Role in Phantom Limb Phenomena
Reilly, K. T., & Sirigu, A. (2007) · The Neuroscientist · doi:10.1177/1073858407309466 · Cited by 83 · see citing works
Stieglitz, T., Ruf, H. H., Gross, M., Schüettler, M., & Meyer, J.-U. (2002) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(02)00019-2 · Cited by 77 · see citing works
Microchannels as Axonal Amplifiers
FitzGerald, J. J., Lacour, S. P., McMahon, S. B., & Fawcett, J. W. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.909533 · Cited by 76 · see citing works
Chronic recording of regenerating viiith nerve axons with a sieve electrode
Mensinger, A. F., Anderson, D. J., Buchko, C. J., Johnson, M. A., Martin, D. C., Tresco, P. A., Silver, R. B., & Highstein, S. M. (2000) · Journal of Neurophysiology · doi:10.1152/jn.2000.83.1.611 · Cited by 76 · see citing works
FitzGerald, J. J., Lago, N., Benmerah, S., Serra, J., Watling, C. P., Cameron, R. E., Tarte, E., Lacour, S. P., McMahon, S. B., & Fawcett, J. W. (2012) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/1/016010 · Cited by 73 · see citing works
A wafer-scale etching technique for high aspect ratio implantable MEMS structures
Bhandari, R., Negi, S., Rieth, L., & Solzbacher, F. (2010) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2010.06.011 · Cited by 71 · see citing works
Long term chronic recordings from peripheral sensory fibers using a sieve electrode array
Bradley, R. M., Cao, X., Akin, T., & Najafi, K. (1997) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(97)02225-5 · Cited by 69 · see citing works
Lago, N., Udina, E., Ramachandran, A., & Navarro, X. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.891168 · Cited by 68 · see citing works
Solid-state microsensors for cortical nerve recordings
Najafi, K. (1994) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.294009 · Cited by 67 · see citing works
Rat sciatic nerve regeneration through a micromachined silicon chip
Zhao, Q., Drott, J., Laurell, T., Wallman, L., Lindström, K., Bjursten, L. M., Lundborg, G., Montelius, L., & Danielsen, N. (1997) · Biomaterials · doi:10.1016/s0142-9612(96)00112-3 · Cited by 67 · see citing works
Novel Methods for the Guidance and Monitoring of Single Cells and Simple Networks in Culture
Dow, J. A. T., Clark, P., Connolly, P., Curtis, A. S. G., & Wilkinson, C. D. W. (1987) · Journal of Cell Science · doi:10.1242/jcs.1987.supplement_8.4 · Cited by 66 · see citing works
Techniques to Study Spinal-Cord, Peripheral Nerve, and Muscle Activity in Freely Moving Animals
Hoffer, J. A. (2003) · Humana Press eBooks · doi:10.1385/0-89603-185-3:65 · Cited by 66 · see citing works
BioMEMS –Advancing the Frontiers of Medicine
James, T., Mannoor, M. S., & Ivanov, D. V. (2008) · Sensors · doi:10.3390/s8096077 · Cited by 65 · see citing works
Microelectromechanical Systems and Neurosurgery: A New Era in a New Millennium
Roy, S., Ferrara, L., Fleischman, A. J., & Benzel, E. C. (2001) · Neurosurgery · doi:10.1097/00006123-200110000-00003 · Cited by 63 · see citing works
González, C., & Rodrı́guez, M. (1997) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(96)02202-9 · Cited by 63 · see citing works
Ceballos, D., Valero‐Cabré, A., Valderrama, E., Schüttler, M., Stieglitz, T., & Navarro, X. (2002) · Journal of Biomedical Materials Research · doi:10.1002/jbm.10099 · Cited by 61 · see citing works
Neural interfaces for regenerated nerve stimulation and recording
Dario, P., Garzella, P., Toro, M., Micera, S., Alavi, M., Meyer, U., Valderrama, E., Sebatiani, L., Ghelarducci, B., Mazzoni, C., et al. (1998) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.736149 · Cited by 58 · see citing works
Electromyography Pattern-Recognition-Based Control of Powered Multifunctional Upper-Limb Prostheses
Li, G. (2011) · InTech eBooks · doi:10.5772/22876 · Cited by 59 · see citing works
Culture of neural cells on polymers coated surfaces for biosensor applications
Lakard, S., Herlem, G., Villarreal, N. V., Michel, G., Propper, A. Y., Gharbi, T., & Fahys, B. (2004) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.09.001 · Cited by 51 · see citing works
Wallman, L. (2001) · Biomaterials · doi:10.1016/s0142-9612(00)00342-2 · Cited by 49 · see citing works
Stable Detection of Movement Intent From Peripheral Nerves: Chronic Study in Dogs
Dweiri, Y. M., Eggers, T. E., Gonzalez-Reyes, L. E., Drain, J., McCallum, G. A., & Durand, D. M. (2017) · Proceedings of the IEEE · doi:10.1109/jproc.2016.2607520 · Cited by 44 · see citing works
Ramachandran, A., Schuettler, M., Lago, N., Doerge, T., Koch, K. P., Navarro, X., Hoffmann, K.-P., & Stieglitz, T. (2006) · Journal of Neural Engineering · doi:10.1088/1741-2560/3/2/005 · Cited by 46 · see citing works
A SU-8-Based Fully Integrated Biocompatible Inductively Powered Wireless Neurostimulator
Cho, S., Xue, N., Cauller, L. J., Rosellini, W. M., & Lee, J. (2012) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2012.2221155 · Cited by 46 · see citing works
Regenerative Scaffold Electrodes for Peripheral Nerve Interfacing
Clements, I. P., Mukhatyar, V. J., Srinivasan, A., Bentley, J. T., Andreasen, D. S., & Bellamkonda, R. V. (2012) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2012.2217352 · Cited by 46 · see citing works
Neuroelectronic interfacing with cultured multielectrode arrays toward a cultured probe
Rutten, W. L. C., Mouveroux, J. M. P., Buitenweg, J. R., Heida, T., Ruardij, T. G., Marani, E., & Lakke, E. A. J. F. (2001) · Proceedings of the IEEE · doi:10.1109/5.939810 · Cited by 46 · see citing works
Microchannel Electrodes for Recording and Stimulation: In Vitro Evaluation
FitzGerald, J. J., Lacour, S. P., McMahon, S. B., & Fawcett, J. W. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2009.2013960 · Cited by 45 · see citing works
Ensell, G., Banks, D., Ewins, D. J., Balachandran, W., & Richards, P. R. (1996) · Journal of Microelectromechanical Systems · doi:10.1109/84.506199 · Cited by 44 · see citing works
Koch, J., Schüettler, M., Pasluosta, C. F., & Stieglitz, T. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab36df · Cited by 44 · see citing works
Rutten, W. L. C., Frieswijk, T. A., Smit, J. P. A., Rozijn, T. H., & Meier, J. H. (1995) · Biosensors and Bioelectronics · doi:10.1016/0956-5663(95)96802-6 · Cited by 43 · see citing works
Mapping of Small Nerve Trunks and Branches Using Adaptive Flexible Electrodes
Xiang, Z., Sheshadri, S., Lee, S., Wang, J., Xue, N., Thakor, N. V., Yen, S., & Lee, C. (2016) · Advanced Science · doi:10.1002/advs.201500386 · Cited by 40 · see citing works
Selvakumaran, J., Hughes, M. P., Keddie, J. L., & Ewins, D. J. (2003) · International IEEE-EMBS Special Topic Conference on Microtechnologies in Medicine and Biology (MMB) · doi:10.1109/mmb.2002.1002326 · Cited by 40 · see citing works
Consideration of nerve-muscle grafts to improve the control of artificial arms
Kuiken, T. (2003) · Technology and Disability · doi:10.3233/tad-2003-15206 · Cited by 39 · see citing works
In Vivo Biostability of CVD Silicon Oxide and Silicon Nitride Films
Maloney, J. M., Lipka, S. A., & Baldwin, S. P. (2005) · MRS Proceedings · doi:10.1557/proc-872-j14.3 · Cited by 38 · see citing works
Robot assistants: Applications and evolution
Dario, P., Guglielmelli, E., Genovese, V., & Toro, M. (1996) · Robotics and Autonomous Systems · doi:10.1016/0921-8890(96)00006-1 · Cited by 39 · see citing works
Neuro-electronic interfacing with multielectrode arrays
Rutten, W. L. C., Smit, J. P. A., Frieswijk, T. A., Bielen, J. A., Brouwer, A. L. H., Buitenweg, J. R., & Heida, C. (1999) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.765188 · Cited by 39 · see citing works
Spinal Cord Injury: Present and Future Therapeutic Devices and Prostheses
Giszter, S. F. (2008) · Neurotherapeutics · doi:10.1016/j.nurt.2007.10.062 · Cited by 37 · see citing works
Tissue reactions evoked by porous and plane surfaces made out of silicon and titanium
Rosengren, A., Wallman, L., Danielsen, N., Laurell, T., & Bjursten, L. M. (2002) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.991167 · Cited by 37 · see citing works
On the way to total integration of prosthetic pylon with residuum.
Pitkin, M. R. (2009) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2008.08.0112 · Cited by 36 · see citing works
Tissue Reactions to Porous Silicon: A Comparative Biomaterial Study
Rosengren, A., Wallman, L., Bengtsson, M., Laurell, T., Danielsen, N., & Bjursten, L. M. (2000) · physica status solidi (a) · doi:10.1002/1521-396x(200011)182:1 · Cited by 36 · see citing works
Cesium hydroxide (CsOH): a useful etchant for micromachining silicon
Clark, L. D., Lund, J. L., & Edell, D. J. (2003) · Solid-State Sensors, Actuators, and Microsystems Workshop (Hilton Head Workshop) · doi:10.1109/solsen.1988.26419 · Cited by 36 · see citing works
Self-citationMicrotechnical Interfaces to Neurons
Stieglitz, T., & Meyer, J.-U. (1998) · Topics in current chemistry · doi:10.1007/3-540-69544-3_6 · Cited by 35 · see citing works
Santina, C. C. D., Kovacs, G. T. A., & Lewis, E. R. (1997) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(96)00159-8 · Cited by 34 · see citing works
Advances in Applied Electromyography
Mizrahi, J. (2011) · InTech eBooks · doi:10.5772/883 · Cited by 33 · see citing works
Kasper, M., Ellenbogen, B., Hardy, R., Cydis, M., Mojica-Santiago, J., Afridi, A., Spearman, B. S., Singh, I., Kuliasha, C. A., Atkinson, E. W., et al. (2021) · Biomaterials · doi:10.1016/j.biomaterials.2021.121212 · Cited by 32 · see citing works
Protein adsorption on materials for recording sites on implantable microelectrodes
Selvakumaran, J., Keddie, J. L., Ewins, D. J., & Hughes, M. P. (2007) · Journal of Materials Science Materials in Medicine · doi:10.1007/s10856-007-3110-x · Cited by 32 · see citing works
Dario, P., Guglielmelli, E., & Allotta, B. (2002) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.1994.407554 · Cited by 32 · see citing works
Microelectronic and nanoelectronic interfacing techniques for biological systems
Connolly, P., Moores, G. R., Monaghan, W., Shen, J., Britland, S., & Clark, P. (1992) · Sensors and Actuators B: Chemical · doi:10.1016/0925-4005(92)80041-u · Cited by 30 · see citing works
Suppression of scarring in peripheral nerve implants by drug elution
FitzGerald, J. J. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/2/026006 · Cited by 27 · see citing works
Gore, R. K., Choi, Y., Bellamkonda, R., & English, A. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/1/016017 · Cited by 26 · see citing works
Silicon-based microelectrodes for neurophysiology, micromachined from silicon-on-insulator wafers
Ensell, G., Banks, D., Richards, P. R., Balachandran, W., & Ewins, D. J. (2000) · Medical & Biological Engineering & Computing · doi:10.1007/bf02344773 · Cited by 25 · see citing works
Dweiri, Y. M., Stone, M. A., Tyler, D. J., McCallum, G. A., & Durand, D. M. (2016) · Journal of Visualized Experiments · doi:10.3791/54388 · Cited by 23 · see citing works
Synthesis of polymer materials for use as cell culture substrates
Lakard, S., Morand-Villeneuve, N., Lesniewska, É., Lakard, B., Michel, G., Herlem, G., Gharbi, T., & Fahys, B. (2007) · Electrochimica Acta · doi:10.1016/j.electacta.2007.04.098 · Cited by 22 · see citing works
Pitkin, M. R., Cassidy, C., Muppavarapu, R. C., & Edell, D. J. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2187784 · Cited by 22 · see citing works
Self-citationPenetrating multichannel stimulation and recording electrodes in auditory prosthesis research
Anderson, D. J. (2008) · Hearing Research · doi:10.1016/j.heares.2008.01.010 · Cited by 20 · see citing works
Wilkinson, C. D. W. (1995) · Microelectronic Engineering · doi:10.1016/0167-9317(94)00056-z · Cited by 20 · see citing works
Micromachining of flexible neural implants with low-ohmic wire traces using electroplating
Gross, M., Altpeter, D., Stieglitz, T., Schüettler, M., & Meyer, J.-U. (2002) · Sensors and Actuators A Physical · doi:10.1016/s0924-4247(01)00768-3 · Cited by 20 · see citing works
A micromachined silicon sieve electrode for nerve regeneration applications
Akın, T., & Najafi, K. (2002) · International Conference on Solid-State Sensors, Actuators and Microsystems · doi:10.1109/sensor.1991.148818 · Cited by 19 · see citing works
Stoyanova, I. I., van Wezel, R. J. A., & Rutten, W. L. C. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/6/066018 · Cited by 18 · see citing works
- Authors
- Edell, D. J.
- Affiliations
- Harvard University (US)
- Corresponding author
- Edell, David J.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1986-02
- Volume
- BME-33
- Issue
- 2
- Pages
- 203-214
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W1974827846
- Cited by
- 177
- References
- 24
- Citations by year
- 2025: 1 · 2023: 1 · 2022: 2 · 2021: 5 · 2020: 2 · 2019: 5 · 2018: 2 · 2017: 2 · 2016: 6 · 2015: 4 · 2014: 2 · 2013: 2 · 2012: 8
- FWCI
- 0.98
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Biomedical Engineering (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institute of Neurological Disorders and Stroke (5R23NS18459-03)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Physical Sciences › Engineering › Biomedical Engineering › Analog and Mixed-Signal Circuit Design
- Keywords
- peripheral nerve recording, amputees, nerve stump, biocompatibility, nerve regeneration, receptive fields, signal-to-noise ratio, surgical implantation
- MeSH terms
- Amputation, Surgical, Animals, Biocompatible Materials, Nerve Regeneration, Synaptic Transmission, Peripheral Nerves, Rabbits, Tibial Nerve, Transducers
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review