Abstract

A micromachined silicon technology is being developed for the purpose of sensing information from the stumps of amputated mammalian peripheral nerves. Information on long-term biocompatibility, anatomy, and physiology related to the structural design of this sensor is presented. Pertinent materials, fabrication, and surgical implantation issues are discussed. Noise, signal amplitude, and receptive field are considered as the prime determinants of the design of an appropriate electrode contact geometry for the structure. The selectivity of the device is also discussed in terms of the fine structure of the regenerated nerve. Examples of waveforms recorded from rabbit peripheral nerves using this sensor are presented and discussed in terms of electrical and physiological parameters. Possible use of the sensor as a source for a binary code suitable for communication of information to a computer is presented along with discussion of the limitations of the current technology and possible future applications.

Integrity signals

Registry

Crossref · 10.1109/tbme.1986.325892

Cites

24 of 24 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Edell, D. J.
Affiliations
Harvard University (US)
Corresponding author
Edell, David J.
Venue
IEEE Transactions on Biomedical Engineering
Published
1986-02
Volume
BME-33
Issue
2
Pages
203-214
ISSN
0018-9294 (ISSN-L)
OpenAlex
W1974827846
Cited by
177
References
24
Citations by year
2025: 1 · 2023: 1 · 2022: 2 · 2021: 5 · 2020: 2 · 2019: 5 · 2018: 2 · 2017: 2 · 2016: 6 · 2015: 4 · 2014: 2 · 2013: 2 · 2012: 8
FWCI
0.98
Type
journal article
Language
en
Open access
closed
Locations
  • IEEE Transactions on Biomedical Engineering (publishedVersion)
  • PubMed (publishedVersion)
Funders
National Institute of Neurological Disorders and Stroke (5R23NS18459-03)
Topics
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
  • Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
  • Physical Sciences › Engineering › Biomedical Engineering › Analog and Mixed-Signal Circuit Design
Keywords
peripheral nerve recording, amputees, nerve stump, biocompatibility, nerve regeneration, receptive fields, signal-to-noise ratio, surgical implantation
MeSH terms
Amputation, Surgical, Animals, Biocompatible Materials, Nerve Regeneration, Synaptic Transmission, Peripheral Nerves, Rabbits, Tibial Nerve, Transducers

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review