Ordered-subset simultaneous algebraic reconstruction techniques (OS-SART)
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
In this paper, we first demonstrate that two ordered-subset simultaneous algebraic reconstruction techniques (OS-SART) can be heuristically derived from the perspective of data rectification. Then, we study the convergence in the framework of our recent work on the OS version of the Landweber scheme. The first OS-SART is the same as the BSSART formula, which is a special case of the OS version of the Landweber scheme. Hence, it converges in the weighted least square sense even in the case of inconsistent data. Both the OS-SART formulas are tested for reconstruction of CT images from practical data.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Maximum Likelihood Reconstruction for Emission Tomography
Shepp, L. A., & Vardi, Y. (1982) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.1982.4307558 · Cited by 4,429
Cited by
Compressed sensing based interior tomography
Yu, H., & Wang, G. (2009) · Physics in Medicine and Biology · doi:10.1088/0031-9155/54/9/014 · Cited by 519
Self-citationXu, W., Xu, F., Jones, M., Keszthelyi, B., Sedat, J., Agard, D., & Mueller, K. (2010) · Journal of Structural Biology · doi:10.1016/j.jsb.2010.03.018 · Cited by 71
“A similar compromise has been introduced as OS-SART by (Wang and Jiang, 2004).”
Method
Metadata
- Authors
- Wang, G., & Jiang, M.
- Venue
- Journal of X-Ray Science and Technology: Clinical Applications of Diagnosis and Therapeutics
- Publisher
- SAGE Publications
- Published
- 2004-08
- Volume
- 12
- Issue
- 3
- Pages
- 169-177
- ISSN
- 0895-3996 (ISSN-L)
- 1095-9114
- OpenAlex
- W1179297989
- Cited by
- 169
- References
- 1
- FWCI
- 0.80
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.