Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 241

The DOI matches its Crossref record; 56 of the 56 references it cites were found in a registry or an index.

Continuous positive airway pressure devices for the treatment of obstructive sleep apnoea–hypopnoea syndrome: a systematic review and economic analysis

Open access
McDaid, C, Griffin, S, Weatherly, H, Durée, K, van der Burgt, M, van Hout, S, Akers, J, Davies, R, Sculpher, M, Westwood, M · 2009 · Health Technology Assessment

Abstract

OBJECTIVES: To determine the clinical effectiveness, safety and cost-effectiveness of continuous positive airway pressure (CPAP) devices for the treatment of obstructive apnoea-hypopnoea syndrome (OSAHS), compared with the best supportive care, placebo and dental devices. DATA SOURCES: The main search was of fifteen electronic databases, including MEDLINE, EMBASE and the Cochrane Library, up to November 2006. REVIEW METHODS: Randomised controlled trials (RCTs) comparing CPAP with best supportive/usual care, placebo, and dental devices in adults with a diagnosis of OSAHS were included. The primary outcomes of interest were subjective daytime sleepiness assessed by the Epworth Sleepiness Scale (ESS) and objective sleepiness assessed by the Maintenance of Wakefulness Test (MWT) and the Multiple Sleep Latency Test (MSLT). A new economic model was developed to assess incremental cost per quality-adjusted life-year (QALY). The cost-effectiveness of CPAP was compared with that of the use of dental devices and conservative management. The costs and QALYs were compared over a lifetime time horizon. Effectiveness was based on the RCT evidence on sleepiness symptoms (ESS), which was 'mapped' to utilities using individual patient data from a subset of studies. Utilities were expressed on the basis of generic HRQoL instruments [the EQ-5D (EuroQoL-5 Dimensions) in the base-case analysis]. The base-case analysis focused on a male aged 50. A series of subgroup and scenario analyses were also undertaken. RESULTS: The searches yielded 6325 citations, from which 48 relevant clinical effectiveness studies were identified, 29 of these providing data on daytime sleepiness. The majority of the included RCTs did not report using an adequate method of allocation concealment or use an intention-to-treat analysis. Only the studies using a sham CPAP comparator were double blinded. There was a statistically significant benefit with CPAP compared with control (placebo and conservative treatment/usual care) on the ESS [mean difference (MD) -2.7 points, 95% CI -3.45 to -1.96]. However, there was statistical heterogeneity, which was reduced when trials were subgrouped by severity of disease. There was also a significant benefit with CPAP compared with usual care on the MWT. There was a non-statistically significant difference between CPAP and dental devices (six trials) in the impact on daytime sleepiness (ESS) among a population with moderate symptom severity at baseline (MD -0.9, 95% CI -2.1 to 0.4). A review of five studies evaluating the cost-effectiveness of CPAP was undertaken. All existing cost-effectiveness studies had limitations; therefore a new economic model was developed, based on which it was found that, on average, CPAP was associated with higher costs and benefits than dental devices or conservative management. The incremental cost per QALY gained of CPAP was below 20,000 pounds in the base-case analysis and most alternative scenarios. There was a high probability of CPAP being more cost-effective than dental devices and conservative management for a cost-effectiveness threshold of 20,000 pounds per QALY gained. CONCLUSIONS: CPAP is an effective and cost-effective treatment for OSAHS compared with conservative/usual care and placebo in populations with moderate to severe daytime sleepiness, and there may be benefits when the disease is mild. Dental devices may be a treatment option in moderate disease but some uncertainty remains. Further research would be potentially valuable, particularly investigation of the effectiveness of CPAP for populations with mild sleepiness and further trials comparing CPAP with dental devices.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3310/hta13040

Cites

56 of 56 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 56 references

Cited by

See all 241

Metadata

Authors
McDaid, C., Griffin, S., Weatherly, H., Durée, K., van der Burgt, M., van Hout, S., Akers, J., Davies, R., Sculpher, M., & Westwood, M.
Venue
Health Technology Assessment
Published
2009-01
Volume
13
Issue
4
Pages
iii-iv, xi
ISSN
  • 1366-5278 (ISSN-L)
  • 2046-4924
OpenAlex
W1968380651
Cited by
241
References
56
FWCI
1.51
Type
journal article
Language
en
Open access
diamond

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Continuous positive airway pressure devices for the treatment of obstructive sleep apnoea–hypopnoea syndrome: a systematic review and economic analysis. https://app.cochat.ai/papers/10.3310/hta13040
The paper
McDaid, C., Griffin, S., Weatherly, H., Durée, K., van der Burgt, M., van Hout, S., Akers, J., Davies, R., Sculpher, M., & Westwood, M. (2009). Continuous positive airway pressure devices for the treatment of obstructive sleep apnoea–hypopnoea syndrome: a systematic review and economic analysis. Health Technology Assessment. https://doi.org/10.3310/hta13040

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.