Cross-trimester repeated measures testing for Down’s syndrome screening: an assessment
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
OBJECTIVES: To provide estimates and confidence intervals for the performance (detection and false-positive rates) of screening for Down's syndrome using repeated measures of biochemical markers from first and second trimester maternal serum samples taken from the same woman. DESIGN: Stored serum on Down's syndrome cases and controls was used to provide independent test data for the assessment of screening performance of published risk algorithms and for the development and testing of new risk assessment algorithms. SETTING: 15 screening centres across the USA, and at the North York General Hospital, Toronto, Canada. PARTICIPANTS: 78 women with pregnancy affected by Down's syndrome and 390 matched unaffected controls, with maternal blood samples obtained at 11-13 and 15-18 weeks' gestation, and women who received integrated prenatal screening at North York General Hospital at two time intervals: between 1 December 1999 and 31 October 2003, and between 1 October 2006 and 23 November 2007. INTERVENTIONS: Repeated measurements (first and second trimester) of maternal serum levels of human chorionic gonadotrophin (hCG), unconjugated estriol (uE3) and pregnancy-associated plasma protein A (PAPP-A) together with alpha-fetoprotein (AFP) in the second trimester. MAIN OUTCOME MEASURES: Detection and false-positive rates for screening with a threshold risk of 1 in 200 at term, and the detection rate achieved for a false-positive rate of 2%. RESULTS: Published distributional models for Down's syndrome were inconsistent with the test data. When these test data were classified using these models, screening performance deteriorated substantially through the addition of repeated measures. This contradicts the very optimistic results obtained from predictive modelling of performance. Simplified distributional assumptions showed some evidence of benefit from the use of repeated measures of PAPP-A but not for repeated measures of uE3 or hCG. Each of the two test data sets was used to create new parameter estimates against which screening test performance was assessed using the other data set. The results were equivocal but there was evidence suggesting improvement in screening performance through the use of repeated measures of PAPP-A when the first trimester sample was collected before 13 weeks' gestation. A Bayesian analysis of the combined data from the two test data sets showed that adding a second trimester repeated measurement of PAPP-A to the base test increased detection rates and reduced false-positive rates. The benefit decreased with increasing gestational age at the time of the first sample. There was no evidence of any benefit from repeated measures of hCG or uE3. CONCLUSIONS: If realised, a reduction of 1% in false-positive rate with no loss in detection rate would give important benefits in terms of health service provision and the large number of invasive tests avoided. The Bayesian analysis, which shows evidence of benefit, is based on strong distributional assumptions and should not be regarded as confirmatory. The evidence of potential benefit suggests the need for a prospective study of repeated measurements of PAPP-A with samples from early in the first trimester. A formal clinical effectiveness and cost-effectiveness analysis should be undertaken. This study has shown that the established modelling methodology for assessing screening performance may be optimistically biased and should be interpreted with caution.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Towards complete and accurate reporting of studies of diagnostic accuracy: The STARD Initiative.
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L. M., Lijmer, J. G., Moher, D., Rennie, D., de Vet, H. C. W., et al. (2003) · Annals of Internal Medicine · doi:10.7326/0003-4819-138-1-200301070-00010 · Cited by 3,219
Towards complete and accurate reporting of studies of diagnostic accuracy: the STARD initiative
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L. M., Lijmer, J. G., Moher, D., Rennie, D., & de Vet, H. C. W. (2003) · BMJ · doi:10.1136/bmj.326.7379.41 · Cited by 3,215
Towards Complete and Accurate Reporting of Studies of Diagnostic Accuracy: The STARD Initiative
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L. M., Lijmer, J. G., Moher, D., Rennie, D., & de Vet, H. C. W. (2003) · Radiology · doi:10.1148/radiol.2261021292 · Cited by 3,215
Cited by
Global Vascular Guidelines on the management of chronic limb-threatening ischemia.
Conte, M. S., Bradbury, A. W., Kolh, P., White, J. V., Dick, F., Fitridge, R., Mills, J. L., Ricco, J.-B., Suresh, K. R., Murad, M. H., et al. (2019) · Journal of Vascular Surgery · doi:10.1016/j.jvs.2019.02.016 · Cited by 2,015
2016 AHA/ACC Guideline on the Management of Patients With Lower Extremity Peripheral Artery Disease
Gerhard-Herman, M. D., Gornik, H. L., Barrett, C., Barshes, N. R., Corriere, M. A., Drachman, D. E., Fleisher, L. A., Fowkes, F. G. R., Hamburg, N. M., Kinlay, S., et al. (2017) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2016.11.007 · Cited by 1,941
Gerhard-Herman, M. D., Gornik, H. L., Barrett, C., Barshes, N. R., Corriere, M. A., Drachman, D. E., Fleisher, L. A., Fowkes, F. G. R., Hamburg, N. M., Kinlay, S., et al. (2017) · Circulation · doi:10.1161/cir.0000000000000470 · Cited by 1,055
Alldred, S. K., Takwoingi, Y., Guo, B., Pennant, M., Deeks, J. J., Neilson, J. P., & Alfirevic, Z. (2017) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd012599 · Cited by 529
Howard, D. P. J., Banerjee, A., Fairhead, J. F., Hands, L., Silver, L. E., & Rothwell, P. M. (2015) · Circulation · doi:10.1161/circulationaha.115.016424 · Cited by 318
Writing Committee Members, Gerhard-Herman, M. D., Gornik, H. L., Barrett, C., Barshes, N. R., Corriere, M. A., Drachman, D. E., Fleisher, L. A., Fowkes, F. G. R., Hamburg, N. M., et al. (2017) · Vascular Medicine · doi:10.1177/1358863x17701592 · Cited by 264
Viljoen, A., Hoxer, C. S., Johansen, P., Malkin, S., Hunt, B., & Bain, S. C. (2019) · Diabetes, Obesity and Metabolism · doi:10.1111/dom.13564 · Cited by 45
Metadata
- Authors
- Wright, D., Bradbury, I., Malone, F., D’Alton, M., Summers, A., Huang, T., Ball, S., Baker, A., Nix, B., Aitken, D., Crossley, J., Cuckle, H., & Spencer, K.
- Venue
- Health Technology Assessment
- Published
- 2010-07
- Volume
- 14
- Issue
- 33
- Pages
- 1-80
- ISSN
- 1366-5278 (ISSN-L)
- 2046-4924
- OpenAlex
- W2107399712
- Cited by
- 90
- References
- 3
- FWCI
- 5.97
- Type
- journal article
- Language
- en
- Open access
- diamond
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.