Implantable cardioverter defibrillators for the treatment of arrhythmias and cardiac resynchronisation therapy for the treatment of heart failure: systematic review and economic evaluation

Open access
Colquitt, Jill L, Mendes, Diana, Clegg, Andrew J, Harris, Petra, Cooper, Keith, Picot, Joanna, Bryant, Jackie · 2014 · Health Technology Assessment
Cited by 74

The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.

Abstract

Background: This assessment updates and expands on two previous technology assessments that evaluated implantable cardioverter defibrillators (ICDs) for arrhythmias and cardiac resynchronisation therapy (CRT) for heart failure (HF). Objectives: To assess the clinical effectiveness and cost-effectiveness of ICDs in addition to optimal pharmacological therapy (OPT) for people at increased risk of sudden cardiac death (SCD) as a result of ventricular arrhythmias despite receiving OPT; to assess CRT with or without a defibrillator (CRT-D or CRT-P) in addition to OPT for people with HF as a result of left ventricular systolic dysfunction (LVSD) and cardiac dyssynchrony despite receiving OPT; and to assess CRT-D in addition to OPT for people with both conditions. Data sources: Electronic resources including MEDLINE, EMBASE and The Cochrane Library were searched from inception to November 2012. Additional studies were sought from reference lists, clinical experts and manufacturers’ submissions to the National Institute for Health and Care Excellence. Review methods: Inclusion criteria were applied by two reviewers independently. Data extraction and quality assessment were undertaken by one reviewer and checked by a second. Data were synthesised through narrative review and meta-analyses. For the three populations above, randomised controlled trials (RCTs) comparing (1) ICD with standard therapy, (2) CRT-P or CRT-D with each other or with OPT and (3) CRT-D with OPT, CRT-P or ICD were eligible. Outcomes included mortality, adverse events and quality of life. A previously developed Markov model was adapted to estimate the cost-effectiveness of OPT, ICDs, CRT-P and CRT-D in the three populations by simulating disease progression calculated at 4-weekly cycles over a lifetime horizon. Results: A total of 4556 references were identified, of which 26 RCTs were included in the review: 13 compared ICD with medical therapy, four compared CRT-P/CRT-D with OPT and nine compared CRT-D with ICD. ICDs reduced all-cause mortality in people at increased risk of SCD, defined in trials as those with previous ventricular arrhythmias/cardiac arrest, myocardial infarction (MI) > 3 weeks previously, non-ischaemic cardiomyopathy (depending on data included) or ischaemic/non-ischaemic HF and left ventricular ejection fraction ≤ 35%. There was no benefit in people scheduled for coronary artery bypass graft. A reduction in SCD but not all-cause mortality was found in people with recent MI. Incremental cost-effectiveness ratios (ICERs) ranged from £14,231 per quality-adjusted life-year (QALY) to £29,756 per QALY for the scenarios modelled. CRT-P and CRT-D reduced mortality and HF hospitalisations, and improved other outcomes, in people with HF as a result of LVSD and cardiac dyssynchrony when compared with OPT. The rate of SCD was lower with CRT-D than with CRT-P but other outcomes were similar. CRT-P and CRT-D compared with OPT produced ICERs of £27,584 per QALY and £27,899 per QALY respectively. The ICER for CRT-D compared with CRT-P was £28,420 per QALY. In people with both conditions, CRT-D reduced the risk of all-cause mortality and HF hospitalisation, and improved other outcomes, compared with ICDs. Complications were more common with CRT-D. Initial management with OPT alone was most cost-effective (ICER £2824 per QALY compared with ICD) when health-related quality of life was kept constant over time. Costs and QALYs for CRT-D and CRT-P were similar. The ICER for CRT-D compared with ICD was £27,195 per QALY and that for CRT-D compared with OPT was £35,193 per QALY. Limitations: Limitations of the model include the structural assumptions made about disease progression and treatment provision, the extrapolation of trial survival estimates over time and the assumptions made around parameter values when evidence was not available for specific patient groups. Conclusions: In people at risk of SCD as a result of ventricular arrhythmias and in those with HF as a result of LVSD and cardiac dyssynchrony, the interventions modelled produced ICERs of < £30,000 per QALY gained. In people with both conditions, the ICER for CRT-D compared with ICD, but not CRT-D compared with OPT, was < £30,000 per QALY, and the costs and QALYs for CRT-D and CRT-P were similar. A RCT comparing CRT-D and CRT-P in people with HF as a result of LVSD and cardiac dyssynchrony is required, for both those with and those without an ICD indication. A RCT is also needed into the benefits of ICD in non-ischaemic cardiomyopathy in the absence of dyssynchrony. Study registration: This study is registered as PROSPERO number CRD42012002062. Funding: The National Institute for Health Research Health Technology Assessment programme.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3310/hta18560

Cites

16 of 16 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 16 references

Cited by

Metadata

Authors
Colquitt, J. L., Mendes, D., Clegg, A. J., Harris, P., Cooper, K., Picot, J., & Bryant, J.
Venue
Health Technology Assessment
Published
2014-08
Volume
18
Issue
56
Pages
1-560
ISSN
  • 1366-5278 (ISSN-L)
  • 2046-4924
OpenAlex
W1993257960
Cited by
74
References
16
FWCI
1.62
Type
journal article
Language
en
Open access
diamond

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.