Clinical effectiveness and cost-effectiveness results from the randomised controlled Trial of Oral Mandibular Advancement Devices for Obstructive sleep apnoea–hypopnoea (TOMADO) and long-term economic analysis of oral devices and continuous positive airway pressure
Open accessThe DOI matches its Crossref record; 90 of the 90 references it cites were found in a registry or an index.
Abstract
Background: Obstructive sleep apnoea–hypopnoea (OSAH) causes excessive daytime sleepiness (EDS), impairs quality of life (QoL) and increases cardiovascular disease and road traffic accident risks. Continuous positive airway pressure (CPAP) treatment is clinically effective but undermined by intolerance, and its cost-effectiveness is borderline in milder cases. Mandibular advancement devices (MADs) are another option, but evidence is lacking regarding their clinical effectiveness and cost-effectiveness in milder disease. Objectives: (1) Conduct a randomised controlled trial (RCT) examining the clinical effectiveness and cost-effectiveness of MADs against no treatment in mild to moderate OSAH. (2) Update systematic reviews and an existing health economic decision model with data from the Trial of Oral Mandibular Advancement Devices for Obstructive sleep apnoea–hypopnoea (TOMADO) and newly published results to better inform long-term clinical effectiveness and cost-effectiveness of MADs and CPAP in mild to moderate OSAH. TOMADO: A crossover RCT comparing clinical effectiveness and cost-effectiveness of three MADs: self-moulded [SleepPro 1™ (SP1); Meditas Ltd, Winchester, UK]; semibespoke [SleepPro 2™ (SP2); Meditas Ltd, Winchester, UK]; and fully bespoke [bespoke MAD (bMAD); NHS Oral-Maxillofacial Laboratory, Addenbrooke’s Hospital, Cambridge, UK] against no treatment, in 90 adults with mild to moderate OSAH. All devices improved primary outcome [apnoea–hypopnoea index (AHI)] compared with no treatment: relative risk 0.74 [95% confidence interval (CI) 0.62 to 0.89] for SP1; relative risk 0.67 (95% CI 0.59 to 0.76) for SP2; and relative risk 0.64 (95% CI 0.55 to 0.76) for bMAD (p < 0.001). Differences between MADs were not significant. Sleepiness [as measured by the Epworth Sleepiness Scale (ESS)] was scored 1.51 [95% CI 0.73 to 2.29 (SP1)] to 2.37 [95% CI 1.53 to 3.22 (bMAD)] lower than no treatment (p < 0.001), with SP2 and bMAD significantly better than SP1. All MADs improved disease-specific QoL. Compliance was lower for SP1, which was unpopular at trial exit. At 4 weeks, all devices were cost-effective at £20,000/quality-adjusted life-year (QALY), with SP2 the best value below £39,800/QALY. Meta-analysis: A MEDLINE, EMBASE and Science Citation Index search updating two existing systematic reviews (one from November 2006 and the other from June 2008) to August 2013 identified 77 RCTs in adult OSAH patients comparing MAD with conservative management (CM), MADs with CPAP or CPAP with CM. MADs and CPAP significantly improved AHI [MAD −9.3/hour (p < 0.001); CPAP −25.4/hour (p < 0.001)]. Effect difference between CPAP and MADs was 7.0/hour (p < 0.001), favouring CPAP. No trials compared CPAP with MADs in mild OSAH. MAD and CPAP reduced the ESS score similarly [MAD 1.6 (p < 0.001); CPAP 1.6 (p < 0.001)]. Long-term cost-effectiveness: An existing model assessed lifetime cost–utility of MAD and CPAP in mild to moderate OSAH, using the revised meta-analysis to update input values. The TOMADO provided utility estimates, mapping ESS score to European Quality of Life-5 Dimensions three-level version for device cost–utility. Using SP2 as the standard device, MADs produced higher mean costs and mean QALYs than CM [incremental cost-effectiveness ratio (ICER) £6687/QALY]. From a willingness to pay (WTP) of £15,367/QALY, CPAP is cost-effective, although the likelihood of MADs (p = 0.48) and CPAP (p = 0.49) being cost-effective is very similar. Both were better than CM, but there was much uncertainty in the choice between CPAP and MAD (at a WTP £20,000/QALY, the probability of being the most cost-effective was 47% for MAD and 52% for CPAP). When SP2 lifespan increased to 18 months, the ICER for CPAP compared with MAD became £44,066. The ICER for SP1 compared with CM was £1552, and for bMAD compared with CM the ICER was £13,836. The ICER for CPAP compared with SP1 was £89,182, but CPAP produced lower mean costs and higher mean QALYs than bMAD. Differential compliance rates for CPAP reduces cost-effectiveness so MADs become less costly and more clinically effective with CPAP compliance 90% of SP2. Conclusions: Mandibular advancement devices are clinically effective and cost-effective in mild to moderate OSAH. A semi-bespoke MAD is the appropriate first choice in most patients in the short term. Future work should explore whether or not adjustable MADs give additional clinical and cost benefits. Further data on longer-term cardiovascular risk and its risk factors would reduce uncertainty in the health economic model and improve precision of effectiveness estimates. Trial registration: This trial is registered as ISRCTN02309506. Funding: This project was funded by the National Institute for Health Research (NIHR) Health Technology Assessment programme and will be published in full in Health Technology Assessment; Vol. 18, No. 67. See the NIHR Journals Library website for further project information.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ware, J. E. (2000) · Spine · doi:10.1097/00007632-200012150-00008 · Cited by 4,455
The epidemiology of adult obstructive sleep apnea
Punjabi, N. M. (2008) · Proceedings of the American Thoracic Society · doi:10.1513/pats.200709-155mg · Cited by 2,361
Longitudinal Study of Moderate Weight Change and Sleep-Disordered Breathing
Peppard, P. E. (2000) · JAMA · doi:10.1001/jama.284.23.3015 · Cited by 2,020
Adherence to Continuous Positive Airway Pressure Therapy: The Challenge to Effective Treatment
Weaver, T. E., & Grunstein, R. R. (2008) · Proceedings of the American Thoracic Society · doi:10.1513/pats.200708-119mg · Cited by 1,680
Obstructive sleep apnoea and its cardiovascular consequences
Bradley, T. D., & Floras, J. S. (2009) · The Lancet · doi:10.1016/s0140-6736(08)61622-0 · Cited by 1,385
Obstructive Sleep Apnea–Hypopnea and Incident Stroke: The Sleep Heart Health Study
Redline, S., Yenokyan, G., Gottlieb, D. J., Shahar, E., O'Connor, G. T., Resnick, H. E., Diener-West, M., Sanders, M. H., Wolf, P. A., Geraghty, E. M., et al. (2010) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200911-1746oc · Cited by 1,269
Obstructive Sleep Apnea, Obesity, and the Risk of Incident Atrial Fibrillation
Gami, A. S., Hodge, D. O., Herges, R. M., Olson, E. J., Nykodym, J., Kara, T., & Somers, V. K. (2007) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.08.060 · Cited by 1,104
Kaneko, Y., Floras, J. S., Usui, K., Plante, J., Tkacova, R., Kubo, T., Ando, S.-I., & Bradley, T. D. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa022479 · Cited by 1,051
Continuous positive airways pressure for obstructive sleep apnoea in adults
Giles, T., Lasserson, T., Smith, B., White, J., Wright, J., & Cates, C. (2006) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd001106.pub2 · Cited by 1,001
McNicholas, W. T., Bonsignore, M. R., & the Management Committee of EU COST ACTION B26 (2007) · European Respiratory Journal · doi:10.1183/09031936.00027406 · Cited by 911
Cited by
Global burden of sleep‐disordered breathing and its implications
Lyons, M. M., Bhatt, N. Y., Pack, A. I., & Magalang, U. J. (2020) · Respirology · doi:10.1111/resp.13838 · Cited by 422
Randerath, W., Bassetti, C. L., Bonsignore, M. R., Farre, R., Ferini-Strambi, L., Grote, L., Hedner, J., Kohler, M., Martinez-Garcia, M.-A., Mihaicuta, S., et al. (2018) · European Respiratory Journal · doi:10.1183/13993003.02616-2017 · Cited by 245
Mandibular Advancement Devices for OSA: An Alternative to CPAP?
Francis, C. E., & Quinnell, T. (2021) · Pulmonary Therapy · doi:10.1007/s41030-020-00137-2 · Cited by 37
Self-citationKim, H. J., Hong, S.-N., Lee, W. H., Ahn, J.-C., Cha, M.-S., Rhee, C.-S., & Kim, J.-W. (2018) · European Archives of Oto-Rhino-Laryngology · doi:10.1007/s00405-018-5007-3 · Cited by 8
Metadata
- Authors
- Sharples, L., Glover, M., Clutterbuck-James, A., Bennett, M., Jordan, J., Chadwick, R., Pittman, M., East, C., Cameron, M., Davies, M., Oscroft, N., Smith, I., Morrell, M., Fox-Rushby, J., & Quinnell, T.
- Venue
- Health Technology Assessment
- Published
- 2014-10
- Volume
- 18
- Issue
- 67
- Pages
- 1-296
- ISSN
- 1366-5278 (ISSN-L)
- 2046-4924
- OpenAlex
- W2313242108
- Cited by
- 63
- References
- 90
- FWCI
- 2.53
- Type
- journal article
- Language
- en
- Open access
- diamond
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.