CoChat

Autoantibody testing in children with newly diagnosed type 1 diabetes mellitus

Open access
Dretzke, J, Cummins, C, Sandercock, J, Fry-Smith, A, Barrett, T, Burls, A · 2004 · Health Technology Assessment
Cited by 77

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Abstract

OBJECTIVES: To determine the role of autoantibody tests for autoimmune diseases in children with newly diagnosed type 1 diabetes mellitus. DATA SOURCES: MEDLINE, EMBASE and the Cochrane Library. Citation lists of included studies were scanned and relevant professional and patient websites reviewed. Laboratories and manufacturers were contacted to identify ongoing or unpublished research. REVIEW METHODS: Following scoping searches on thyroid and coeliac autoantibodies, a systematic review of autoantibody tests for diagnosis of coeliac disease was carried out. Studies were included where cohorts of untreated patients with unknown disease status were included, all patients had undergone the reference test (biopsy) and antibody tests, and sensitivity and specificity were reported or calculable. Selected studies were then evaluated against a quality checklist. Summary statistics of diagnostic accuracy, i.e. sensitivity, specificity, positive and negative likelihood ratios and diagnostic odds ratios, were calculated for all studies. A decision analytic model was developed to evaluate the cost utility of screening for coeliac disease at diagnosis of diabetes. RESULTS: All antibody tests for diagnosis of coeliac disease showed reasonably good diagnostic test accuracy. Studies reported variable measures of test accuracy, which may be due to aspects of study quality, differences in the tests and their execution in the laboratories, different populations and reference standards. The decision analytic model indicated screening for coeliac disease at diagnosis of diabetes was cost-effective. Sensitivity analyses exploring variations in the cost and disutility of gluten-free diet, the utilities attached to treated and untreated coeliac disease and the decrease in life expectancy associated with treated and untreated coeliac disease did substantially affect the cost-effectiveness of the screening strategies considered. CONCLUSIONS: In terms of test accuracy in testing for coeliac disease, immunoglobulin A (IgA) anti-endomysium is the most accurate test. If an enzyme-linked immunoassay test was required, which may be more suitable for screening purposes as it can be semi-automated, testing for IgA tissue transglutaminase is likely to be most accurate. The decision analytic model shows that the most accurate tests combined with confirmatory biopsy are the most cost-effective, whilst combinations of tests add little or no further value. There is limited information regarding test accuracy in screening populations with diabetes, and there is some uncertainty over whether the test characteristics would remain the same. Further research is required regarding the role of screening in silent coeliac disease and regarding long-term outcomes and complications of untreated coeliac disease.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3310/hta8220

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 77

Metadata

Authors
Dretzke, J., Cummins, C., Sandercock, J., Fry-Smith, A., Barrett, T., & Burls, A.
Venue
Health Technology Assessment
Published
2004-06
Volume
8
Issue
22
Pages
iii-xi, 1
ISSN
  • 1366-5278 (ISSN-L)
  • 2046-4924
OpenAlex
W2162236733
Cited by
77
References
8
FWCI
0.48
Type
journal article
Language
en
Open access
diamond

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.