CoChat

The effectiveness and cost-effectiveness of dual-chamber pacemakers compared with single-chamber pacemakers for bradycardia due to atrioventricular block or sick sinus syndrome: systematic review and economic evaluation

Open access
Castelnuovo, E, Stein, K, Pitt, M, Garside, R, Payne, E · 2005 · Health Technology Assessment
Cited by 127

The DOI matches its Crossref record.

Abstract

OBJECTIVES: To estimate the effectiveness and cost-effectiveness of dual-chamber pacemakers versus single-chamber atrial or single-chamber ventricular pacemakers in the treatment of bradycardia due to sick sinus syndrome (SSS) or atrioventricular block (AVB). DATA SOURCES: Electronic databases and relevant Internet sites. Contact with device manufacturers and experts in the field. REVIEW METHODS: A systematic review was carried out of randomised controlled trials (RCTs). The quality of selected studies was appraised using standard frameworks. Meta-analyses, using random effects models, were carried out where appropriate. Limited exploration of heterogeneity was possible. Critical appraisal of economic evaluations was carried out using two frameworks. A decision-analytic model was developed using a Markov approach, to estimate the cost-effectiveness of dual-chamber versus ventricular or atrial pacing over 5 and 10 years as cost per quality-adjusted life-year (QALY). Uncertainty was explored using one-way and probabilistic sensitivity analyses. RESULTS: The searches retrieved a systematic review of effectiveness and cost-effectiveness published in 2002, four parallel group RCTs and 28 cross-over trials. Dual-chamber pacing was associated with lower rates of atrial fibrillation, particularly in SSS, than ventricular pacing, and prevents pacemaker syndrome. Higher rates of atrial fibrillation were seen with dual-chamber pacing than with atrial pacing. Complications occurred more frequently in dual-chamber pacemaker insertion. The cost of a dual-chamber system, over 5 years, including cost of complications and subsequent clinical events in the population, was estimated to be around 7400 pounds. The overall cost difference between single and dual systems is not large over this period: around 700 pounds more for dual-chamber devices. The cost-effectiveness of dual-chamber compared with ventricular pacing was estimated to be around 8500 pounds per QALY in AVB and 9500 pounds in SSS over 5 years, and around 5500 pounds per QALY in both populations over 10 years. Under more conservative assumptions, the cost-effectiveness of dual-chamber pacing is around 30,000 pounds per QALY. The probabilistic sensitivity analysis showed that, under the base-case assumptions, dual-chamber pacing is likely to be considered cost-effective at levels of willingness to pay that are generally considered acceptable by policy makers. In contrast, atrial pacing may be cost-effective compared with dual-chamber pacing. CONCLUSIONS: Dual-chamber pacing results in small but potentially important benefits in populations with SSS and/or AVB compared with ventricular pacemakers. Pacemaker syndrome is a crucial factor in determining cost-effectiveness; however, difficulties in standardising diagnosis and measurement of severity make it difficult to quantify. Dual-chamber pacing is in common usage in the UK. Recipients are more likely to be younger. Insufficient evidence is currently available to inform policy on specific groups who may benefit most from pacing with dual-chamber devices. Further important research is underway. Outstanding research priorities include the economic evaluation of UKPACE studies of the classification, diagnosis and utility associated with pacemaker syndrome and evidence on the effectiveness of pacemakers in children.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3310/hta9430

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 127

Metadata

Authors
Castelnuovo, E., Stein, K., Pitt, M., Garside, R., & Payne, E.
Venue
Health Technology Assessment
Published
2005-11
Volume
9
Issue
43
Pages
iii, xi-xiii, 1
ISSN
  • 1366-5278 (ISSN-L)
  • 2046-4924
OpenAlex
W1970616811
Cited by
127
References
0
FWCI
0.44
Type
journal article
Language
en
Open access
diamond
Funders
Health Technology Assessment programme (03/25/01)

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The effectiveness and cost-effectiveness of dual-chamber pacemakers compared with single-chamber pacemakers for bradycardia due to atrioventricular block or sick sinus syndrome: systematic review and economic evaluation. https://app.cochat.ai/papers/10.3310/hta9430
The paper
Castelnuovo, E., Stein, K., Pitt, M., Garside, R., & Payne, E. (2005). The effectiveness and cost-effectiveness of dual-chamber pacemakers compared with single-chamber pacemakers for bradycardia due to atrioventricular block or sick sinus syndrome: systematic review and economic evaluation. Health Technology Assessment. https://doi.org/10.3310/hta9430

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.