The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Hypersensitivity reactions to intravenous iron: guidance for risk minimization and management
Open accessAbstract
Intravenous iron is widely used for the treatment of iron deficiency anemia when oral iron is inappropriate, ineffective or poorly tolerated. Acute hypersensitivity reactions during iron infusions are very rare but can be life-threatening. This paper reviews their frequency, pathogenesis and risk factors, and provides recommendations about their management and prevention. Complement activation-related pseudo-allergy triggered by iron nanoparticles is probably a more frequent pathogenetic mechanism in acute reactions to current formulations of intravenous iron than is an immunological IgE-mediated response. Major risk factors for hypersensitivity reactions include a previous reaction to an iron infusion, a fast iron infusion rate, multiple drug allergies, severe atopy, and possibly systemic inflammatory diseases. Early pregnancy is a contraindication to iron infusions, while old age and serious co-morbidity may worsen the impact of acute reactions if they occur. Management of iron infusions requires meticulous observation, and, in the event of an adverse reaction, prompt recognition and severity-related interventions by well-trained medical and nursing staff.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Jahn, M. R., Andreasen, H. B., Fütterer, S., Nawroth, T., Schünemann, V., Kolb, U., Hofmeister, W., Muñoz, M., Bock, K., Meldal, M., et al. (2011) · European Journal of Pharmaceutics and Biopharmaceutics · doi:10.1016/j.ejpb.2011.03.016 · Cited by 256
Anaemia in inflammatory rheumatic diseases
Weiss, G., & Schett, G. (2013) · Nature Reviews Rheumatology · doi:10.1038/nrrheum.2012.183 · Cited by 146
Self-citation
Cited by
Camaschella, C. (2015) · New England Journal of Medicine · doi:10.1056/nejmra1401038 · Cited by 1,678
Weiss, G., Ganz, T., & Goodnough, L. T. (2019) · Blood · doi:10.1182/blood-2018-06-856500 · Cited by 1,219
Self-citationCamaschella, C. (2019) · Blood · doi:10.1182/blood-2018-05-815944 · Cited by 702
Berger, M. M., Shenkin, A., Schweinlin, A., Amrein, K., Augsburger, M., Biesalski, H.-K., Bischoff, S. C., Casaer, M. P., Gundogan, K., Lepp, H.-L., et al. (2022) · Clinical Nutrition · doi:10.1016/j.clnu.2022.02.015 · Cited by 615
Iron considerations for the athlete: a narrative review
Sim, M., Garvican-Lewis, L. A., Cox, G. R., Govus, A., McKay, A. K. A., Stellingwerff, T., & Peeling, P. (2019) · European Journal of Applied Physiology · doi:10.1007/s00421-019-04157-y · Cited by 274
Metadata
- Authors
- Rampton, D., Folkersen, J., Fishbane, S., Hedenus, M., Howaldt, S., Locatelli, F., Patni, S., Szebeni, J., & Weiss, G.
- Venue
- Haematologica
- Published
- 2014-11-01
- Volume
- 99
- Issue
- 11
- Pages
- 1671-1676
- ISSN
- 0390-6078 (ISSN-L)
- 1592-8721
- OpenAlex
- W2056969309
- Cited by
- 315
- References
- 2
- FWCI
- 16.45
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Hypersensitivity reactions to intravenous iron: guidance for risk minimization and management. https://app.cochat.ai/papers/10.3324/haematol.2014.111492
- The paper
- Rampton, D., Folkersen, J., Fishbane, S., Hedenus, M., Howaldt, S., Locatelli, F., Patni, S., Szebeni, J., & Weiss, G. (2014). Hypersensitivity reactions to intravenous iron: guidance for risk minimization and management. Haematologica. https://doi.org/10.3324/haematol.2014.111492
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.