Dried Blood Spot Multiplexed Steroid Profiling Using Liquid Chromatography Tandem Mass Spectrometry in Korean Neonates
Open accessThe DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Screening for congenital adrenal hyperplasia (CAH) using immunoassays for 17α-hydroxyprogesterone generates many false-positive results. We developed and validated a liquid chromatography-tandem mass spectrometry (LC-MS/MS) assay for simultaneous quantification of nine steroid hormones in dried blood spot (DBS) samples, and established reference intervals for these hormones. METHODS: We examined our method for linearity, precision, accuracy, extraction recovery, and matrix effects and determined the reference intervals of cortisol, 17α-hydroxyproges-terone, 11-deoxycortisol, 21-deoxycortisol, androstenedione, corticosterone, 11-deoxycorticosterone, testosterone, and progesterone in 1,146 DBS samples (from 272 preterm and 874 full-term neonates). Immunoassay and LC-MS/MS methods were compared for 17α-hydroxyprogesterone. Fourteen additional samples were tested to validate the clinical applicability of the LC-MS/MS method. RESULTS: <0.0001). The LC-MS/MS method was successfully applied to the analysis of nine steroids in DBS for screening and diagnosis of CAH using the 14 additional samples. CONCLUSIONS: Our method enables highly sensitive and specific assessment of nine steroids from DBS and is a promising tool for clinical analysis of CAH.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Lacey, J. M., Minutti, C. Z., Magera, M. J., Tauscher, A. L., Casetta, B., McCann, M., Lymp, J., Hahn, S. H., Rinaldo, P., & Matern, D. (2004) · Clinical Chemistry · doi:10.1373/clinchem.2003.027193 · Cited by 216
Janzen, N., Peter, M., Sander, S., Steuerwald, U., Terhardt, M., Holtkamp, U., & Sander, J. (2007) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2006-2890 · Cited by 211
Travers, S., Martinerie, L., Bouvattier, C., Boileau, P., Lombès, M., & Pussard, E. (2017) · The Journal of Steroid Biochemistry and Molecular Biology · doi:10.1016/j.jsbmb.2016.06.005 · Cited by 81
Janzen, N., Sander, S., Terhardt, M., Steuerwald, U., Peter, M., Das, A. M., & Sander, J. (2011) · Steroids · doi:10.1016/j.steroids.2011.07.013 · Cited by 66
Seo, J. Y., Park, H.-D., Kim, J. W., Oh, H. J., Yang, J. S., Chang, Y. S., Park, W. S., & Lee, S.-Y. (2014) · jpme · doi:10.1515/jpm-2013-0154 · Cited by 55
Determination of a steroid profile in heel prick blood using LC-MS/MS
Boelen, A., Ruiter, A. F., Claahsen-van der Grinten, H. L., Endert, E., & Ackermans, M. T. (2016) · Bioanalysis · doi:10.4155/bio.16.6 · Cited by 49
Kim, B., Lee, M.-N., Park, H.-D., Kim, J. W., Chang, Y. S., Park, W. S., & Lee, S.-Y. (2015) · Annals of Laboratory Medicine · doi:10.3343/alm.2015.35.6.578 · Cited by 32
Self-citation
Research works printed but not linked: 15
- Rauh, 2009, Mol Cell Endocrinol, 301, 272, 10.1016/j.mce.2008.10.007 · DOI
- Rossi, 2010, Clin Chim Acta, 411, 222, 10.1016/j.cca.2009.11.007 · DOI
- Magnisali, 2011, J Chromatogr B Analyt Technol Biomed Life Sci, 879, 1565, 10.1016/j.jchromb.2011.03.048 · DOI
- Horowitz, 2010, Defining, establishing, and verifying reference intervals in the clinical laboratory, approved guideline. EP28-A3
- International Conference on Harmonisation (ICH), 2005, Int Conf Harmon, 1994, 17
- CLSI, 2003, Evaluation of the linearity of quantitative measurement procedures: A statistical approach; approved guideline. CLSI document EP06A
- CLSI, 2015, Spectrometry for androgen and estrogen measurements in serum. CLSI guideline C57
- CLSI, 2017, Screening by tandem mass spectrometry. CLSI guideline NBS04
- CLSI, 2018, Measurement procedure comparison and bias estimation using patient samples. CLSI guideline EP09c
- Dietzen, 2016, Clin Chem, 62, 1658, 10.1373/clinchem.2016.263434 · doi:10.1373/clinchem.2016.263434
- Matuszewski, 2003, Anal Chem, 75, 3019, 10.1021/ac020361s · DOI · Paper page
- Hicks, 2014, Metabolomics, 10, 123, 10.1007/s11306-013-0558-1 · DOI · Paper page
- Janzen, 2008, J Chromatogr B Analyt Technol Biomed Life Sci, 861, 117, 10.1016/j.jchromb.2007.11.006 · DOI
- Fiet, 2017, J Endocr Soc, 1, 186
- Monostori, 2015, Horm Res Paediatr, 84, 311, 10.1159/000439380 · DOI
Cited by
Lai, F., Srinivasan, S., & Wiley, V. (2020) · International Journal of Neonatal Screening · doi:10.3390/ijns6030063 · Cited by 32
Grecsó, N., Zádori, A., Szécsi, I., Baráth, Á., Galla, Z., Bereczki, C., & Monostori, P. (2020) · PLoS ONE · doi:10.1371/journal.pone.0233724 · Cited by 26
Adachi, E., Nakagawa, R., Tsuji-Hosokawa, A., Gau, M., Kirino, S., Yogi, A., Nakatani, H., Takasawa, K., Yamaguchi, T., Kosho, T., et al. (2024) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/clinem/dgad577 · Cited by 16
Cho, S.-E., Han, J., Park, J.-H., Park, E., Kim, G. Y., Lee, J. H., Yi, A., Lee, S. G., Lee, E. H., & Yun, Y.-M. (2023) · Annals of Laboratory Medicine · doi:10.3343/alm.2023.43.1.19 · Cited by 3
“Testosterone in neonates has been measured using dried blood spot multi-plexed steroid profiling using LC-MS/MS [25].”
Self-citation
Metadata
- Authors
- Choi, R., Park, H.-D., Oh, H. J., Lee, K., Song, J., & Lee, S.-Y.
- Venue
- Annals of Laboratory Medicine
- Publisher
- Annals of Laboratory Medicine
- Published
- 2019-05-01
- Volume
- 39
- Issue
- 3
- Pages
- 263-270
- ISSN
- 2234-3806 (ISSN-L)
- 2234-3814
- OpenAlex
- W2909058683
- Cited by
- 29
- References
- 7
- FWCI
- 1.07
- Type
- journal article
- Language
- en
- Open access
- diamond
- Licence
- creativecommons.org/licenses/by-nc/4.0/ (tdm)
- Funders
- Ministry of Health & Welfare (A120030)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Dried Blood Spot Multiplexed Steroid Profiling Using Liquid Chromatography Tandem Mass Spectrometry in Korean Neonates. https://app.cochat.ai/papers/10.3343/alm.2019.39.3.263
- The paper
- Choi, R., Park, H.-D., Oh, H. J., Lee, K., Song, J., & Lee, S.-Y. (2019). Dried Blood Spot Multiplexed Steroid Profiling Using Liquid Chromatography Tandem Mass Spectrometry in Korean Neonates. Annals of Laboratory Medicine. https://doi.org/10.3343/alm.2019.39.3.263
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.