Efficacy and Safety of Radiofrequency Ablation for Benign Thyroid Nodules: A Prospective Multicenter Study

Open access
Jung, So Lyung, Baek, Jung Hwan, Lee, Jeong Hyun, Shong, Young Kee, Sung, Jin Yong, Kim, Kyu Sun, Lee, Ducky, Kim, Ji-hoon, Baek, Seon Mi, Sim, Jung Suk, Na, Dong Gyu · 2018 · Korean Journal of Radiology

Abstract

Objective: To assess the efficacy and safety of thyroid radiofrequency (RF) ablation for benign thyroid nodules by trained radiologists according to a unified protocol in a multi-center study.Materials and Methods: From 2010 to 2011, 345 nodules from 345 patients (M:F = 43:302; mean age ± SD = 46.0 ± 12.7 years, range = 15-79) who met eligibility criteria were enrolled from five institutions.At pre-ablation, the mean volume was 14.2 ± 13.2 mL (1.1-80.8mL).For 12 months or longer after treatment, 276 lesions, consisting of 248 solid and 28 predominantly cystic nodules, were followed.All operators performed RF ablation with a cool-tip RF system and two standard techniques (a transisthmic approach and the moving-shot technique).Volume reduction at 12 months after RF ablation (the primary outcome), therapeutic success, improvement of symptoms as well as of cosmetic problems, and complications were evaluated.Multiple linear regression analysis was applied to identify factors that were independently predictive of volume reduction.Results: The mean volume reduction at 12 months was 80.3% (n = 276) and at the 24-, 36-, 48-, and 60-month follow-ups 84.3% (n = 198), 89.2% (n = 128), 91.9% (n = 57), and 95.3% (n = 6), respectively.Our therapeutic success was 97.8%.Both mean symptom and cosmetic scores showed significant improvements (p < 0.001).The rate of major complications was 1.0% (3/276).Solidity and applied energy were independent factors that predicted volume reduction.Conclusion: Radiofrequency ablation performed by trained radiologists from multiple institutions using a unified protocol and similar devices was effective and safe for treating benign thyroid nodules.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3348/kjr.2018.19.1.167

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 213

Metadata

Authors
Jung, S. L., Baek, J. H., Lee, J. H., Shong, Y. K., Sung, J. Y., Kim, K. S., Lee, D., Kim, J.-H., Baek, S. M., Sim, J. S., & Na, D. G.
Venue
Korean Journal of Radiology
Published
2018
Volume
19
Issue
1
Pages
167
ISSN
  • 1229-6929 (ISSN-L)
  • 2005-8330
OpenAlex
W2776420589
Cited by
213
References
4
FWCI
17.91
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Efficacy and Safety of Radiofrequency Ablation for Benign Thyroid Nodules: A Prospective Multicenter Study. https://app.cochat.ai/papers/10.3348/kjr.2018.19.1.167
The paper
Jung, S. L., Baek, J. H., Lee, J. H., Shong, Y. K., Sung, J. Y., Kim, K. S., Lee, D., Kim, J.-H., Baek, S. M., Sim, J. S., & Na, D. G. (2018). Efficacy and Safety of Radiofrequency Ablation for Benign Thyroid Nodules: A Prospective Multicenter Study. Korean Journal of Radiology. https://doi.org/10.3348/kjr.2018.19.1.167

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.