The Utility of Three Screening Questionnaires for Obstructive Sleep Apnea in a Sleep Clinic Setting
Open accessThe DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
PURPOSE: The aim of this study was to determine the diagnostic value of three screening questionnaires in identifying Korean patients at high risk for obstructive sleep apnea (OSA) in a sleep clinic setting in Korea. MATERIALS AND METHODS: Data were collected from 592 adult patients with suspected OSA who visited a sleep center. All patients completed the Sleep Apnea of Sleep Disorder Questionnaire (SA-SDQ), the Berlin questionnaire, and the STOP-Bang questionnaire. Estimated OSA risk was compared to a diagnosis of OSA. The sensitivity, specificity, positive predictive value, and negative predictive value were calculated for each questionnaire. RESULTS: The prevalence of OSA was 83.6% using an apnea-hypopnea index (AHI) ≥5/h and 58.4% for an AHI ≥15/h. The STOP-Bang questionnaire had a high sensitivity (97% for AHI ≥5/h, 98% for AHI ≥15/h), but the specificity was low (19% and 11%, respectively). In contrast, the sensitivity of the SA-SDQ was not high enough (68% for AHI ≥5/h, 74% for AHI ≥15/h) to be useful in a clinical setting, whereas the specificity was relatively good (66% and 61%, respectively). The sensitivity and specificity values of the Berlin questionnaire fell between those of the STOP-Bang questionnaire and the SA-SDQ. CONCLUSION: The STOP-Bang questionnaire may be useful for screening OSA in a sleep clinic setting, but its specificity is lower than the acceptable level for this purpose. A new screening questionnaire with a high sensitivity and acceptable specificity is therefore needed in a sleep clinic setting.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Using the Berlin Questionnaire To Identify Patients at Risk for the Sleep Apnea Syndrome
Netzer, N. C., Stoohs, R. A., Netzer, C. M., Clark, K., & Strohl, K. P. (1999) · Annals of Internal Medicine · doi:10.7326/0003-4819-131-7-199910050-00002 · Cited by 2,973
Sleep-disordered Breathing and Cardiovascular Disease
SHAHAR, E., WHITNEY, C. W., REDLINE, S., LEE, E. T., NEWMAN, A. B., JAVIER NIETO, F., O'CONNOR, G. T., BOLAND, L. L., SCHWARTZ, J. E., & SAMET, J. M. (2001) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.163.1.2001008 · Cited by 2,901
Self-citationSTOP Questionnaire: A Tool to Screen Patients for Obstructive Sleep Apnea
Chung, F., Yegneswaran, B., Liao, P., Chung, S. A., Vairavanathan, S., Islam, S., Khajehdehi, A., & Shapiro, C. M. (2008) · Anesthesiology · doi:10.1097/aln.0b013e31816d83e4 · Cited by 2,355
Kushida, C. A., Littner, M. R., Morgenthaler, T., Alessi, C. A., Bailey, D., Coleman, J., Friedman, L., Hirshkowitz, M., Kapen, S., Kramer, M., et al. (2005) · Sleep · doi:10.1093/sleep/28.4.499 · Cited by 2,054
Evaluating patient-based outcome measures for use in clinical trials.
Fitzpatrick, Davey, Buxton, & Jones (1998) · Health Technology Assessment · doi:10.3310/hta2140 · Cited by 1,715
A systematic review of screening questionnaires for obstructive sleep apnea
Abrishami, A., Khajehdehi, A., & Chung, F. (2010) · Canadian Journal of Anesthesia/Journal canadien d'anesthésie · doi:10.1007/s12630-010-9280-x · Cited by 581
Chung, F., Yegneswaran, B., Liao, P., Chung, S. A., Vairavanathan, S., Islam, S., Khajehdehi, A., & Shapiro, C. M. (2008) · Anesthesiology · doi:10.1097/aln.0b013e31816d91b5 · Cited by 571
Craniofacial profile in Asian and white subjects with obstructive sleep apnoea
Lam, B. (2005) · Thorax · doi:10.1136/thx.2004.031591 · Cited by 212
Cited by
Kapur, V. K., Auckley, D. H., Chowdhuri, S., Kuhlmann, D. C., Mehra, R., Ramar, K., & Harrod, C. G. (2017) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.6506 · Cited by 3,253
“33 52 The studies were conducted in a wide variety of geographic locations including Brazil, 38 Canada, 34,42 Greece, 37 Iran, 36 Korea, 40 Turkey, 43 and the United States.”
Prevalence of obstructive sleep apnea in the general population: A systematic review
Senaratna, C. V., Perret, J. L., Lodge, C. J., Lowe, A. J., Campbell, B. E., Matheson, M. C., Hamilton, G. S., & Dharmage, S. C. (2017) · Sleep Medicine Reviews · doi:10.1016/j.smrv.2016.07.002 · Cited by 2,581
Chiu, H.-Y., Chen, P.-Y., Chuang, L.-P., Chen, N.-H., Tu, Y.-K., Hsieh, Y.-J., Wang, Y.-C., & Guilleminault, C. (2017) · Sleep Medicine Reviews · doi:10.1016/j.smrv.2016.10.004 · Cited by 650
Senaratna, C. V., Perret, J. L., Matheson, M. C., Lodge, C. J., Lowe, A. J., Cassim, R., Russell, M. A., Burgess, J. A., Hamilton, G. S., & Dharmage, S. C. (2017) · Sleep Medicine Reviews · doi:10.1016/j.smrv.2017.04.001 · Cited by 214
Screening Questionnaires for Obstructive Sleep Apnea: An Updated Systematic Review
Amra, B., Rahmati, B., Soltaninejad, F., & Feizi, A. (2018) · Oman Medical Journal · doi:10.5001/omj.2018.36 · Cited by 142
Metadata
- Authors
- Kim, B., Lee, E. M., Chung, Y.-S., Kim, W.-S., & Lee, S.-A.
- Venue
- Yonsei Medical Journal
- Published
- 2015
- Volume
- 56
- Issue
- 3
- Pages
- 684
- ISSN
- 0513-5796 (ISSN-L)
- 1976-2437
- OpenAlex
- W2024581539
- Cited by
- 65
- References
- 8
- FWCI
- 4.52
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Utility of Three Screening Questionnaires for Obstructive Sleep Apnea in a Sleep Clinic Setting. https://app.cochat.ai/papers/10.3349/ymj.2015.56.3.684
- The paper
- Kim, B., Lee, E. M., Chung, Y.-S., Kim, W.-S., & Lee, S.-A. (2015). The Utility of Three Screening Questionnaires for Obstructive Sleep Apnea in a Sleep Clinic Setting. Yonsei Medical Journal. https://doi.org/10.3349/ymj.2015.56.3.684
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.