The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Effects of the cold pressor test on cardiac autonomic control in normal subjects
Open accessAbstract
The cold pressor test (CPT) triggers in healthy subjects a vascular sympathetic activation and an increase in blood pressure. The heart rate (HR) response to this test is less well defined, with a high inter-individual variability. We used traditional spectral analysis together with the non-linear detrended fluctuation analysis to study the autonomic control of HR during a 3-min CPT. 39 healthy young subjects (23.7±3.2 years, height 180.4±4.7 cm and weight 73.3±6.4 kg) were divided into two groups according to their HR responses to CPT. Twenty subjects have a sustained increase in HR throughout the test with reciprocal autonomic interaction, i.e. increase in sympathetic activity and decrease vagal outflow. In the 19 remainders, HR decreased after an initial increase, with indication of involvement of both sympathetic and vagal outflow. Baseline evaluation of the subjects revealed no difference between the two groups. Nevertheless, a higher sympathetic activity at the skin level during CPT was present in the group with decreased HR. Further studies are needed to explain why healthy subjects react differently to the CPT and if this has potential clinical implications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Heart rate variability: Standards of measurement, physiological interpretation, and clinical use
Malik, M., Bigger, J. T., Camm, A. J., Kleiger, R. E., Malliani, A., Moss, A. J., & Schwartz, P. J. (1996) · European Heart Journal · doi:10.1093/oxfordjournals.eurheartj.a014868 · Cited by 15,289
Yasuma, F., & Hayano, J.-I. (2004) · Chest · doi:10.1378/chest.125.2.683 · Cited by 907
Parati, G., Casadei, R., Groppelli, A., Di Rienzo, M., & Mancia, G. (1989) · Hypertension · doi:10.1161/01.hyp.13.6.647 · Cited by 899
Shibahara, N., Matsuda, H., Umeno, K., Shimada, Y., Itoh, T., & Terasawa, K. (1996) · Journal of the Autonomic Nervous System · doi:10.1016/s0165-1838(96)00065-3 · Cited by 28
Cited by
Tesarz, J., Schuster, A. K., Hartmann, M., Gerhardt, A., & Eich, W. (2012) · Pain · doi:10.1016/j.pain.2012.03.005 · Cited by 324
Olafsdottir, G., Cloke, P., Schulz, A., van Dyck, Z., Eysteinsson, T., Thorleifsdottir, B., & Vögele, C. (2020) · Environment and Behavior · doi:10.1177/0013916518800798 · Cited by 193
Pankratov, V., Mezzavilla, M., Aneli, S., Kuznetsov, I. A., Fusco, D., Wilson, J. F., Metspalu, M., Provero, P., Pagani, L., & Marnetto, D. (2024) · European Journal of Human Genetics · doi:10.1038/s41431-024-01678-9 · Cited by 10
Metadata
- Authors
- Mourot, L., Bouhaddi, M., & Regnard, J.
- Venue
- Physiological Research
- Published
- 2009
- Volume
- 58
- Issue
- 1
- Pages
- 83-91
- ISSN
- 0862-8408 (ISSN-L)
- 1802-9973
- OpenAlex
- W2143620016
- Cited by
- 170
- References
- 4
- FWCI
- 2.17
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.