The DOI matches its Crossref record; 62 of the 62 references it cites were found in a registry or an index.
Titanium–Tissue Interface Reaction and Its Control With Surface Treatment
Open accessAbstract
Titanium (Ti) and its alloys are widely used for medical and dental implant devices — artificial joints, bone fixators, spinal fixators, dental implant, etc. — because they show excellent corrosion resistance and good hard-tissue compatibility (bone formation and bone bonding ability) among metals. Osseointegration is the first requirement of the interface structure between titanium and bone tissue. This concept of osseointegration was immediately spread to dental-materials researchers worldwide to show the advantages of titanium as an implant material compared with other metals. Since the concept of osseointegration was developed, the cause of osseointegration has been actively investigated. The surface chemical state, adsorption characteristic of protein, and bone tissue formation process have also been evaluated. To accelerate osseointegration, roughened and porous surfaces are effective. HA and TiO2 coatings prepared by plasma spray and an electrochemical technique, as well as alkalinization of the surface, are also effective to improve hard-tissue compatibility. Various immobilization techniques for biofunctional molecules have been developed for bone formation and prevention of platelet and bacteria adhesion. These techniques make it possible to apply Ti to a scaffold of tissue engineering. The elucidation of the mechanism of the excellent biocompatibility of Ti can provide a shorter way to develop optimal surfaces. This review should enhance the understanding of the properties and biocompatibility of Ti and highlight the significance of surface treatment.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
1 retracted
A comprehensive review of hydroxyapatite-based coatings adhesion on metallic biomaterials
Harun, W. S. W., Asri, R. I. M., Alias, J., Zulkifli, F. H., Kadirgama, K., Ghani, S. A. C., & Shariffuddin, J. H. M. (2018) · Ceramics International · doi:10.1016/j.ceramint.2017.10.162 · Cited by 349
RetractedCRC Handbook of Chemistry and Physics
(2016) · CRC Press eBooks · doi:10.1201/9781315380476 · Cited by 13,921
(2013) · doi:10.1016/c2009-0-02433-7 · Cited by 5,127
Osseointegrated implants in the treatment of the edentulous jaw. Experience from a 10-year period.
Brånemark, P. I., Hansson, B. O., Adell, R., Breine, U., Lindström, J., Hallén, O., & ÖHMAN, A. E. (1977) · PubMed · Cited by 2,385
Wang, X., Xu, S., Zhou, S., Xu, W., Leary, M., Choong, P., Qian, M., Brandt, M., & Xie, Y. M. (2016) · Biomaterials · doi:10.1016/j.biomaterials.2016.01.012 · Cited by 2,121
Brunette, D. M., Tengvall, P., Textor, M., & Thomsen, P. (2001) · Engineering Materials · doi:10.1007/978-3-642-56486-4 · Cited by 1,547
Design and mechanical properties of new β type titanium alloys for implant materials
Kuroda, D., Niinomi, M., Morinaga, M., Kato, Y., & Yashiro, T. (1998) · Materials Science and Engineering A · doi:10.1016/s0921-5093(97)00808-3 · Cited by 1,323
Effect of Low-Temperature Phase Changes on the Mechanical Properties of Alloys near Composition TiNi
Buehler, W. J., Gilfrich, J. V., & Wiley, R. C. (1963) · Journal of Applied Physics · doi:10.1063/1.1729603 · Cited by 1,151
Albrektsson, T. O., & Wennerberg, A. (2004) · PubMed · Cited by 1,118
Preparation of bioactive Ti and its alloys via simple chemical surface treatment
Kim, H.-M., Miyaji, F., Kokubo, T., & Nakamura, T. (1996) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199611)32:3<409::aid-jbm14>3.0.co;2-b · Cited by 1,005
Cited by
Fit and forget: The future of dental implant therapy via nanotechnology
Gulati, K., Chopra, D., Kocak-Oztug, N. A., & Verron, E. (2023) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2023.114900 · Cited by 89
Toxicity Evaluation of TiO2 Nanoparticles on the 3D Skin Model: A Systematic Review
Sanches, P. L., Geaquinto, L. R. D. O., Cruz, R., Schuck, D. C., Lorencini, M., Granjeiro, J. M., & Ribeiro, A. R. L. (2020) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2020.00575 · Cited by 70
Metadata
- Authors
- Hanawa, T.
- Venue
- Frontiers in Bioengineering and Biotechnology
- Publisher
- Frontiers Media SA
- Published
- 2019-07-17
- Volume
- 7
- Pages
- 170-170
- ISSN
- 2296-4185 (ISSN-L)
- OpenAlex
- W2958674338
- Cited by
- 284
- References
- 62
- FWCI
- 10.85
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Titanium–Tissue Interface Reaction and Its Control With Surface Treatment. https://app.cochat.ai/papers/10.3389/fbioe.2019.00170
- The paper
- Hanawa, T. (2019). Titanium–Tissue Interface Reaction and Its Control With Surface Treatment. Frontiers in Bioengineering and Biotechnology. https://doi.org/10.3389/fbioe.2019.00170
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.